Skin-mounted marker based motion capture systems are widely used in measuring the movement of human joints. Kinematic measurements associated with skin-mounted markers are subject to soft tissue artifacts (STA), since the markers follow skin movement, thus generating errors when used to represent motions of underlying bone segments. We present a novel ultrasound tracking system that is capable of directly measuring tibial and femoral bone surfaces during dynamic motions, and subsequently measuring six-degree-of-freedom (6-DOF) tibiofemoral kinematics. The aim of this study is to quantitatively compare the accuracy of tibiofemoral kinematics estimated by the ultrasound tracking system and by a conventional skin-mounted marker based motion capture system in a cadaveric experimental scenario. Two typical tibiofemoral joint models (spherical and hinge models) were used to derive relevant kinematic outcomes. Intra-cortical bone pins equipped with optical markers were inserted in the tibial and femoral bones to serve as a reference to provide ground truth kinematics. The ultrasound tracking system resulted in lower kinematic errors than the skin-mounted markers (the ultrasound tracking system: maximum root-mean-square (RMS) error 3.44° for rotations and 4.88 mm for translations, skin-mounted markers with the spherical joint model: 6.32° and 6.26 mm, the hinge model: 6.38° and 6.52 mm). Our proposed ultrasound tracking system has the potential of measuring direct bone kinematics, thereby mitigating the influence and propagation of STA. Consequently, this technique could be considered as an alternative method for measuring 6-DOF tibiofemoral kinematics, which may be adopted in gait analysis and clinical practice.
Periprosthetic bone loss is an important factor in tibial implant failure mechanisms in total knee arthroplasty (TKA). The purpose of this study was to validate computational postoperative bone response using longitudinal clinical DEXA densities. Computational remodeling outcome over a population was obtained by incorporating the strain-adaptive remodeling theory in finite element (FE) simulations of 26 different tibiae. Physiological loading conditions were applied, and bone mineral density (BMD) in three different regions of interest (ROIs) was considered over a postoperative time of 15 years. BMD outcome was compared directly to previously reported clinical BMD data of a comparable TKA cohort. Similar trends between computational and clinical bone remodeling over time were observed in the two proximal ROIs, with most rapid bone loss taking place in the initial months after TKA and BMD starting to level in the following years. The extent of absolute proximal BMD change was underestimated in the FE population compared with the clinical subject group, which might be the result of significantly higher initial clinical baseline BMD values.Large differences in remodeling response were found in the distal ROI, in which resorption was measured clinically, but a large BMD increase was predicted by the FE models. Multiple computational limitations, related to the FE mesh, loading conditions, and strain-adaptive algorithm, likely contributed to the extensive local bone formation. Further research incorporating subject-specific comparisons using followup CT scans and more extensive physiological knee loading is recommended to optimize bone remodeling more distal to the tibial baseplate.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.