The use of cold atmospheric pressure plasma jets for in vivo treatments implies most of the time plasma interaction with conductive targets. The effect of conductive target contact on the discharge behavior is studied here for a grounded metallic target and compared to the free jet configuration. In this work, realized with a plasma gun, we measured helium metastable He M (2 3 S 1 ) concentration (by laser absorption spectroscopy) and electric field (EF) longitudinal and radial components (by electro-optic probe). Both diagnostics were temporally and spatially resolved. Mechanisms after ionization front impact on the target surface have been identified. The remnant conductive ionized channel behind the ionization front electrically transiently connects the inner high voltage electrode to the target. Due to impedance mismatching between the ionized channel and the target, a secondary ionization front is initiated and rapidly propagates from the target surface to the inner electrode through this ionized channel. This leads to a greatly enhanced He M production inside the plasma plume and the capillary. Forward and reverse dynamics occur with further multi reflections of more or less damped ionization fronts between the inner electrode and the target as long as the ionized channel is persisting. This phenomenon is very sensitive to parameters such as target distance and ionized channel conductivity affecting electrical coupling between these two and evidenced using positive or negative voltage polarity and nitrogen admixture. In typical operating conditions for the plasma gun used in this work, it has been found that after the secondary ionization front propagation, when the ionized channel is conductive enough, a glow like discharge occurs with strong conduction current. He M production and all species excitation, especially reactive ones, are then driven by high voltage pulse evolution. The control of forward and reverse dynamics, impacting on the production of the glow like discharge, will be useful for biomedical applications on living tissues.
This paper presents a combined 2D numerical and experimental study of the influence of N 2 admixture on the dynamics of a He-N 2 discharge in the 10 cm long dielectric tube of a plasma gun set-up. First, the comparison between experiments and simulations is carried out on the ionization front propagation velocity in the tube. The importance of taking into account a detailed kinetic scheme for the He-N 2 mixture in the simulations to obtain a good agreement with the experiments is put forward. For the μs driven plasma gun, the two-and three-body Penning reactions occurring in the plasma column behind the ionization front, are shown to play a key role on the discharge dynamics. In the experiments and simulations, the significant influence of the amplitude of the applied voltage on the ionization front propagation velocity is observed. As the amount of N 2 varies, simulation results show that the ionization front velocity, depends on a complex coupling between the kinetics of the discharge, the photoionization and the 2D structure of the discharge in the tube. Finally, the time evolution of axial and radial components of the electric field measured by an electro-optic probe set outside the tube are compared with simulation results. A good agreement is obtained on both components of the electric field. In the tube, simulations show that the magnitude of the axial electric field on the discharge axis depends weakly on the amount of N 2 conversely to the magnitude of the off-axis peak electric field. Both, simulations and first measurements in the tube or within the plasma plume show peak electric fields of the order of 45 kV•cm −1 .
Atmospheric pressure plasma propagation inside long dielectric tubes is analyzed for the first time through nonintrusive and nonperturbative time resolved bi-directional electric field (EF) measurements. This study unveils that plasma propagation occurs in a region where longitudinal EF exists ahead the ionization front position usually revealed from plasma emission with ICCD measurement. The ionization front propagation induces the sudden rise of a radial EF component. Both of these EF components have an amplitude of several kV/cm for helium or neon plasmas and are preserved almost constant along a few tens of cm inside a capillary. All these experimental measurements are in excellent agreement with previous model calculations. The key roles of the voltage pulse polarity and of the target nature on the helium flow patterns when plasma jet is emerging in ambient air are documented from Schlieren visualization. The second part of this work is then dedicated to the development of multi jet systems, using two different setups, based on a single plasma source. Plasma splitting in dielectric tubes drilled with sub millimetric orifices, but also plasma transfer across metallic tubes equipped with such orifices are reported and analyzed from ICCD imaging and time resolved EF measurements. This allows for the design and the feasibility validation of plasma jet arrays but also emphasizes the necessity to account for voltage pulse polarity, target potential status, consecutive helium flow modulation, and electrostatic influence between the produced secondary jets. V
Modifications of rare gas flow by plasma generated with a plasma gun (PG) are evidenced through simultaneous time-resolved ICCD imaging and schlieren visualization. The geometrical features of the capillary inside which plasma propagates before in-air expansion, the pulse repetition rate and the presence of a metallic target are playing a key role on the rare gas flow at the outlet of the capillary when the plasma is switched on. In addition to the previously reported upstream offset of the laminar to turbulent transition, we document the reverse action leading to the generation of long plumes at moderate gas flow rates together with the channeling of helium flow under various discharge conditions. For higher gas flow rates, in the l min −1 range, time-resolved diagnostics performed during the first tens of ms after the PG is turned on, evidence that the plasma plume does not start expanding in a laminar neutral gas flow. Instead, plasma ignition leads to a gradual laminar-like flow build-up inside which the plasma plume is generated. The impact of such phenomena for gas delivery on targets mimicking biological samples is emphasized, as well as their consequences on the production and diagnostics of reactive species.
In this work, helium flow modifications, visualized by schlieren imaging, induced by the plasma generated in a plasma jet have been studied in conditions used for biomedical treatments (jet being directed downwards with a low helium flow rate). It has been shown that the plasma action can shift up to few centimeters downstream the effects of buoyancy, which allows to the helium flow to reach a target below in conditions for which it is not the case when the plasma is off. This study reveals the critical role of large and long lifetime negative ions during repetitive operations in the kHz regime, inducing strong modifications in the gas propagation. The cumulative added streamwise momentum transferred to ambient air surrounding molecules resulting from a series of applied voltage pulses induces a gradual built up of a helium channel on tens of millisecond timescale. In some conditions, a remarkable stable cylindrical helium channel can be generated to the target with plasma supplied by negative polarity voltage pulses whereas a disturbed flow results from positive polarity operation. This has a direct effect on air penetration in the helium channel and then on the reactive species production over the target which is of great importance for biomedical applications. It has also been shown that with an appropriate combination of negative and positive polarity pulses, it is possible to benefit from both polarity features in order to optimize the plasma plume propagation and plasma delivery to a target.
The lack of oxygen is a major reason for the resistance of tumor cells to treatments such as radiotherapies. A large number of recent publications on non-thermal plasma applications in medicine report cell behavior modifications and modulation of soluble factors. This in vivo study tested whether such modifications can lead to vascular changes in response to plasma application. Two in situ optical-based methods were used simultaneously, in real time, to assess the effect of non-thermal plasma on tissue vasculature. Tissue oxygen partial pressure (pO 2 ) was measured using a time-resolved luminescence-based optical probe, and the microvascular erythrocyte flow was determined by laser Doppler flowmetry. When plasma treatment was applied on mouse skin, a rapid pO 2 increase (up to 4 times) was subcutaneously measured and correlated with blood flow improvement. Such short duration, i.e. 5 min, plasma-induced effects were shown to be locally restricted to the treated area and lasted over 120 min. Further investigations should elucidate the molecular mechanisms of these processes. However, improvement of oxygenation and perfusion open new opportunities for tumor treatments in combination with radiotherapy, and for tumor blood vessel normalization based strategies.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.