Orthodontic forces delivered by thermoplastic appliances depend on the material, thickness, and amount of activation. Mechanical properties of the polymers obtained by nanoindentation testing are predictive of force delivery by these appliances.
The effects of 2 years of storage and 6000 thermocycles on the shear bond strength (SBS) of two self-etching adhesive systems were studied. Two self-etching primer (SEP) systems (Transbond Plus and Beauty Ortho Bond) and one etch and rinse system (Transbond XT) were used to bond brackets to 126 human premolars that were then stored in artificial saliva for 24 hours or 2 years and thermocycled in distilled water before SBS testing with a universal testing machine. The adhesive remnant index (ARI) scores were calculated. Data were compared by two-way analysis of variance and chi-square analysis. Enamel/adhesive interfaces were examined by scanning electron microscopy. There was no significant difference in the mean SBS for the bonding materials among the three conditions. ARI scores showed that Transbond XT and Beauty Ortho Bond had less adhesive remaining on the teeth after ageing compared with storage for 24 hours. Specimens bonded with Beauty Ortho Bond showed leakage between the resin adhesive and enamel after ageing. Both SEP systems produced adequate SBS even after 2 years or 6000 times thermocycling. Thermocycling is an appropriate technique for determining the durability of orthodontic bracket bonding materials.
Objective: To determine the effect of coating on the properties of two esthetic orthodontic nickeltitanium wires. Materials and Methods: Woowa (polymer coating; Dany Harvest) and BioForce High Aesthetic Archwire (metal coating; Dentsply GAC) with cross-section dimensions of 0.016 3 0.022 inches were selected. Noncoated posterior regions of the anterior-coated Woowa and uncoated Sentalloy were used for comparison. Nominal coating compositions were determined by x-ray fluorescence (JSX-3200, JOEL). Cross-sectioned and external surfaces were observed with a scanning electron microscope (SEM; SSX-550, Shimadzu) and an atomic force microscope (SPM-9500J2, Shimadzu). A three-point bending test (12-mm span) was carried out using a universal testing machine (EZ Test, Shimadzu). Hardness and elastic modulus of external and cross-sectioned surfaces were obtained by nanoindentation (ENT-1100a, Elionix; n 5 10). Results: Coatings on Woowa and BioForce High Aesthetic Archwire contained 41% silver and 14% gold, respectively. The coating thickness on Woowa was approximately 10 mm, and the coating thickness on BioForce High Aesthetic Archwire was much smaller. The surfaces of both coated wires were rougher than the noncoated wires. Woowa showed a higher mean unloading force than the noncoated Woowa, although BioForce High Aesthetic Archwire showed a lower mean unloading force than Sentalloy. While cross-sectional surfaces of all wires had similar hardness and elastic modulus, values for the external surface of Woowa were smaller than for the other wires. Conclusions: The coating processes for Woowa and BioForce High Aesthetic Archwire influence bending behavior and surface morphology. (Angle Orthod. 2012;82:319-325.)
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.