In this paper, we propose a serial dilution microfluidic chip which is able to generate logarithmic or linear step-wise concentrations. These concentrations were generated via adjustments in the flow rate of two converging fluids at the channel junctions of the ladder network. The desired dilution ratios are almost independent of the flow rate or diffusion length of molecules, as the dilution device is influenced only by the ratio of volumetric flow rates. Given a set of necessary dilution ratios, whether linear or logarithmic, a serial dilution chip can be constructed via the modification of a microfluidic resistance network. The design principle was suggested and both the logarithmic and linear dilution chips were fabricated in order to verify their performance in accordance with the fluorescence intensity. The diluted concentrations of a fluorescein solution in the microfluidic device evidenced relatively high linearity, and the cytotoxicity test of MCF-7 breast cancer cells via the logarithmic dilution chip was generally consistent with the results generated with manual dilution.
Glass-based microchannel chips were fabricated using photolithographic technology, and Pt thin-film microelectrodes, as coplanar impedance sensors, were integrated on them. Longitudinal design parameters, such as interelectrode spacing and electrode width, of coplanar impedance sensors were changed to determine AC frequency characteristics as design parameters. Through developing total impedance equations and modeling equivalent circuits, the dominant components in each frequency region were illustrated for coplanar impedance sensors and the measured results were compared with fitted values. As the ionic concentration increased, the value of the frequency-independent region decreased and cut-off frequencies increased. As the interelectrode spacing increased, cut-off frequencies decreased and total impedance increased. However, the width of each frequency-independent region was similar. As the electrode area increased, f(low) decreased but f(high) was fixed. We think that the decrease in R(Sol) dominated over the influence of other components, which resulted in heightening f(low) and f(high). The interelectrode spacing is a more significant parameter than the electrode area in the frequency characteristics of coplanar sensors. The deviation of experimentally obtained results from theoretically predicted values may result from the fringing effect of coplanar electrode structure and parasitic capacitance due to dielectric substrates. We suggest the guidelines of dominant components for sensing as design parameters.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.