A method combining hydrophilic interaction liquid chromatography (HILIC) with tandem mass spectrometry (MS/MS) was developed for the determination of polar organophosphorus pesticides (OPPs; acephate, methamidophos, monocrotophos, omethoate, oxydemeton-methyl, and vamidothion) in water samples. To extract the polar OPPs and minimize matrix effects from the water sample, an activated carbon cartridge was used for pretreatment. After pretreatment of the water sample, the eluate from the activated carbon cartridge was directly injected into the HILIC/MS/MS system. The OPPs were separated on an Atlantis HILIC silica column by isocratic elution with a mixture of acetonitrile, isopropanol, and ammonium formate buffer as a mobile phase, and they were detected by positive electrospray ionization MS/MS in the selected reaction monitoring mode. The method was validated at 0.05, 0.5, and 5 microg/L levels in water samples, and the recoveries of polar OPPs were between 76.4 and 98.6%. The limits of detection were between 0.13 and 1.0 pg on-column, and the limits of quantification were between 0.43 and 3.4 pg on-column. The method can be applied to the determination of trace amounts of OPPs in environmental water samples.
A simple and rapid method for determining ethylenebisdithiocarbamates (EBDCs; mancozeb, maneb, and zineb) in fruits and vegetables is described. EBDCs are transformed into dimethylethylenebisdithiocarbamate (EBDC-dimethyl) by methylation after their decomposition with ethylenediaminetetraacetic acid (EDTA). These processes were performed simultaneously in this method. Dimethyl sulfate was used as the methylation reagent, and acetonitrile extracts obtained from partitioning with anhydrous magnesium sulfate and sodium chloride were subjected to dispersive solid-phase extraction with the primary secondary amine sorbent. Liquid chromatography with tandem mass spectrometry in the positive heated-electrospray ionization mode was used for the determination of EBDC-dimethyl produced from EBDCs. The method was validated at levels of 10, 50, and 100 ng g(-1) maneb as a representative EBDC. The recoveries of the present method were between 71 and 101%. The limits of detection and quantification were 0.24 and 0.8 ng g(-1) maneb, respectively.
We have developed a novel method for selective and sensitive analysis of sialic acids (N-acetylneuraminic, N-glycolylneuraminic, and 2-keto-3-deoxy-D-glycero-D-galactonononic acid) utilizing liquid chromatography/tandem mass spectrometry (LC/MS/MS) combined with a fluorous derivatization technique. In this method, the carboxylic groups in the sialic acids are derivatized via amidation with heptadecafluoroundecylamine, a commercially available perfluoroalkylamine reagent. This reaction proceeds rapidly and readily at room temperature in the presence of a condensation reagent. Subsequently, the derivatives are retained specifically on an LC column with a perfluoroalkyl stationary phase by means of a fluorophilic or 'fluorous' interaction, and detected by positive electrospray ionization MS/MS. The detection limits of the examined sialic acids are in the range of 60-750 amol on column. We show that the proposed method can be used to analyze trace amounts of sialic acids in biological samples.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.