Background According to the medical literature, both on-pump and off-pump coronary artery surgery is safe and effective in octogenarians. Objectives The aim of our study was to examine the epidemiology, in-hospital outcomes and long-term follow-up results in octogenarians undergoing off-pump and on-pump coronary artery surgery utilizing nationwide registry data. Methods All octogenarians (� 80 years) enrolled in the Polish National Registry of Cardiac Surgical Procedures (KROK Registry), who underwent isolated coronary surgery between January 2006 and September 2017 were identified. Preoperative data, perioperative complications, hospital mortality and long-term mortality were analyzed. Unadjusted and propensitymatched comparisons were performed between octogenarians undergoing off-pump and on-pump coronary artery bypass surgery.
A 19-year-old woman with atrial septal defect treated percutaneously with an Amplatzer Septal Occluder 24 months earlier, who presented with a history of bacterial meningitis, was admitted with a diagnosis of endocarditis. After 6 weeks of treatment with antibiotics, the incompletely endothelialised occluder was surgically removed. The present report illustrates the need for long-term follow-up of patients who have received nitinol wire mesh occluders.
Ventricular septal defects closure (VSD) depending on the anatomy and clinical setting can be performed surgically or by a hybrid and transcatheter approach. Two cases of children with VSD will be presented. Patients’ defects were closed with various types of occluders made of nitinol wire mesh occluder, patent ductus arteriosus (PDA) type. The first case was a 2.5-year-old boy after cardiosurgical correction of tetralogy of Fallot (TOF). After the procedure, a significant haemodynamic residual VSD was observed, which was not successfully closed during the subsequent reoperation. Despite pharmacological treatment, symptoms of heart failure were observed in this patient. In echocardiographic images the residual VSD was presented as a tunnel-like dissection of the ventricular septum (length 6 mm and diameter 3.4 mm). The defect was closed via arterial access with an Amplatzer Duct Occluder II (ADO II). The procedure was successfully performed without any medical complications. In this child, a significant shunt reduction and a noticeable improvement in the patient's clinical status and diminished symptoms of heart failure were noticed. The second patient was a 4-year-old girl suffering from a multi-perforated perimembranous VSD accompanied by a ventricular septal defect with aneurysm. The defect was closed by a venous approach with a PDA Cardio-O-Fix occluder (very similar to ADO I). No short-term or long-term complications were visible during or after the procedure. Only a mild residual shunt through the VSD was observed 6 months afterwards. Transcatheter VSD closure with a proper morphology, with occluders of type Amplatzer Duct Occluder ADO I or ADO II, constitutes a safe and effective therapeutic alternative.
Current antithrombotic practice among European EXCOR users representing the treatment of more than 600 pediatric patients has changed over time with a trend toward a more aggressive therapy. There is a need for systematic evidence-based evaluation and harmonization of developmentally adjusted antithrombotic management practices in prospective studies toward revised recommendations.
IntroductionThe proportion of valve repair procedures is increasing in experienced centers. The aim of the study was to assess the clinical and echocardiographic outcomes after aortic valve reconstruction with a novel surgical technique.Material and methodsThe study group consisted of 30 patients (23 male and 7 female) at a mean age of 35 ± 14 years. In patients with aortic root aneurysm the reimplantation or Florida sleeve technique was used. A sub-commissural annuloplasty, plication of the free edge of the cusp, shaving, and commissurotomy were performed. At this stage of surgery aortic repair was then attempted by cusp extension. Since 2013 the strips have been tailored from extracellular matrix.ResultsThe mean aortic cross-clamp time was 90 ± 32 min. The mean cardiopulmonary bypass time was 126 ± 38 min. There was no in-hospital death. Re-exploration for bleeding was required in 1 patient. During follow-up, 1 patient needed reoperation at 1 year due to endocarditis. All patients remained alive in New York Heart Association (NYHA) functional class I. The echocardiographic findings remained unchanged in all cases during follow-up.ConclusionsOur modification of aortic valve repair results in a good outcome.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.