Objective: In this study, we investigate about relationship between postoperative global sagittal imbalance and occurrence of mechanical complications after adult spinal deformity (ASD) surgery. In global sagittal balance parameters, odontoid-hip axis (OD-HA) angle and T1 pelvic angle (TPA) were analyzed.Methods: Between January 2009 and December 2016, 199 consecutive patients (26 males and 173 females) with ASD underwent corrective fusion of more than 4 levels and were followed up for more than 2 years. Immediate postoperative and postoperative 2 years whole spine x-rays were checked for evaluating immediate postoperative OD-HA, TPA, and other parameters. In clinical outcomes, back and leg pain visual analogue scale, Scoliosis Research Society-22 spinal deformity questionnaire (SRS-22), Oswestry Disability Index (ODI), 36- item Short Form Health Survey (SF-36) were evaluated.Results: Based on the occurrence of mechanical complications, a comparative analysis was performed for each parameter. In univariable analysis, mechanical complications were significantly much more occurred in OD-HA abnormal group (odds ratio [OR], 3.296; p < 0.001; area under the curve [AUC] = 0.645). In multivariable analysis, the result was much more related (OR, 2.924; p = 0.001; AUC = 0.727). In contrast, there was no significant difference between normal and the occurrence of mechanical complications in TPA. In clinical outcomes (normal vs. abnormal), the differences of SRS-22 (0.88 ± 0.73 vs. 0.68 ± 0.64, p = 0.042), ODI (-24.72 ± 20.16 vs. -19.01 ± 19.95, p = 0.046), SF-36 physical composite score (19.33 ± 18.55 vs. 12.90 ± 16.73, p = 0.011) were significantly improved in OD-HA normal group.Conclusion: The goal of ASD surgery is to improve patient life quality through correction. In our study, TPA was associated with spinopelvic parameter and OD-HA angle was associated with health-related quality of life and complications. OD-HA angle is predictable factor for mechanical complications after ASD surgery.
BackgroundWe report the successful use of allograft–prosthesis composite (APC) and structural femoral head allografting in the bilateral reconstruction of large femoral and tibial uncontained defects during revision total knee arthroplasty (RTKA).Case presentationA 67-year-old female with degenerative arthritis underwent bilateral total knee arthroplasty (TKA) using the Press Fit Condylar (PFC) modular knee system at our clinic in March, 1996. At 8 years postoperatively, the patient presented with painful, bilateral varus knees, with swelling, limited passive range of motion (ROM), and severe instability. We treated to reconstruct both knee using a femoral head allograft at the tibial site, a structural distal femoral allograft at the femoral site, and a varus-valgus constrained (VVC) prosthesis with cement. At the 10-year follow up, we found no infection, graft failure, loosening of implants, in spite of using massive bilateral structural femoral head allografts in RTKA.ConclusionThe use of APC enabled a stable and durable reconstruction in this uncommon presentation with large femoral bone deficiencies encountered during a RTKA.Electronic supplementary materialThe online version of this article (10.1186/s12891-018-1981-2) contains supplementary material, which is available to authorized users.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.