An LC-MS/MS method was developed to quantify an antisense oligonucleotide against Raf-1 expression (rafAON) in monkey and mouse plasma and in mouse tissue homogenates from animals dosed with a liposome-entrapped rafAON easy-to-use formulation (LErafAON-ETU) intended for use as an antineoplastic agent. RafAON was extracted from mouse and monkey plasma using solid-phase extraction. Tissues were homogenized and sample cleanup was achieved by protein precipitation. RafAON and the internal standard (IS) were separated on a Hamilton PRP-1 column and quantified by tandem mass spectrometry using an electrospray source in negative ion mode. The total run time was 4.0 min. The peak areas of two rafAON transitions were summed and plotted against the peak area of an IS transition to generate the standard curve. In monkey plasma the linear range was 50-10,000 ng/mL, and in mouse plasma it was 25-5000 ng/mL. The lower limit of quantification was 500 ng/mL (10 microg/g tissue) in heart, kidney, liver, lung and spleen homogenates, and the standard curve was linear up to 10,000 ng/mL. Accuracy, precision and stability were evaluated and found to be acceptable in all three matrices. The assay was used to support pharmacokinetics and tissue distribution studies of LErafAON-ETU in mice and monkeys.
7-Ethyl-10-hydroxycamptothecin (SN-38) is an active metabolite of Irinotecan (CPT-11), an anticancer pro-drug. To support clinical pharmacokinetic studies for liposome based formulation of SN-38 (LE-SN38) in cancer patients, a rapid, simple and sensitive liquid chromatography tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the quantification of total SN-38 in human plasma. Sample preparation was carried out by one-step protein precipitation using cold acetonitrile with 0.5% acetic acid (v/v). Camptothecin was used as an internal standard (IS). Chromatographic separation of SN-38 and IS was achieved using a Synergi Hydro-RP column (C(18), 50 x 2 mm, 4 micro m), with a gradient elution of acetonitrile and 0.1% acetic acid. After ionization in electrospray source (positive ions), the acquisition was performed in the multiple reactions monitoring mode. Quantitation was accomplished using the precursor-->product ion combinations of m/z 393.1-->349.2 for SN-38 and 349.1-->305.1 for IS. The quantification limit of 0.05 ng/mL was achieved by using much lower volume (0.2 mL) of plasma and in the presence of LE-SN38. The method was validated over the concentration range of 0.05-400 ng/mL. Accuracy was within +/-12% of nominal at all concentration levels. Inter-day and intra-day precisions expressed as percentage coefficient of variation (%CVs) for quality control (QC) samples were less than 14 and 5%, respectively.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.