ObjectiveHigh-sensitivity troponin I (hsTnI) assays lead to, among other things, improvement in the detection of myocardial injury and improved risk stratification of patients with atrial fibrillation (AF). The aim of this study was to investigate the association between post-procedure cardiac biomarkers and clinical outcome in patients undergoing cryo-balloon ablation (CA) for AF.MethodsA total of 57 patients (mean age 55.1 ± 12.2 years, 50.9% female) with symptomatic paroxysmal AF underwent the CA procedure. Two hundred and twenty-eight pulmonary veins (PVs) were attempted for pulmonary vein isolation (PVI) with a second-generation cryo-balloon. hsTnI, CK-MB mass and myoglobin samples were prospectively obtained before and 24 hours after ablation.ResultAt a mean follow up of 214.6 ± 24.3 days, the probability of being arrhythmia free after a single procedure was 86%. Post-ablation hsTnI (p = 0.001), left atrial (LA) diameter (p = 0.002), duration of AF (p = 0.002), mean minimal temperature of the left superior pulmonary vein (p = 0.005), and age (p = 0.021) were associated with increased AF recurrence rate. On multivariate analysis, lower hsTnI level was the only independent predictor for AF recurrence (p = 0.012). Post-ablation hsTnI levels lower than 4.40 ng/ml predicted AF recurrence during follow up, with a sensitivity of 86% and a specificity of 96%.ConclusionIt is well recognised that the PV antrum contributes to initiation and/or perpetuation of AF. A lower postablation hsTnI level may predict an increased AF recurrence rate, suggesting inadequate ablation of the PV antrum. This may be used as a non-invasive marker to predict the outcome of AF.
Objective:The management of anticoagulated patients with warfarin during dental extraction is an intricate issue. We carefully designed the current study so that the amount of bleeding was measured with objective methods and the data from the same patient in different dental extraction appointments could be compared, eliminating the bleeding diathesis differences of patients.Methods:This prospective and controlled study was conducted in 36 adult patients with prosthetic valve requiring multiple tooth extractions. The first dental extraction was performed without the discontinuation of warfarin therapy, and the second procedure was performed with a discontinuation of warfarin and bridging with low-molecular weight heparin (LMWH). The two dental extraction protocols in the same patient group were compared. The total amount of bleeding was calculated as the difference between the weights of gauze swabs used before and after the tamponade; the number of gauze swabs used for bleeding control in the first 48 h was recorded.Result:The median number of used gauze swabs was 2.5 (IQR: 1–5) and 3.0 (IQR: 2–7) in the first and second dental extraction procedures, respectively. The median bleeding time was 50.0 (IQR: 20–100) in the first procedure compared with 60.0 (IQR: 40–140) min in the second procedure. The mean amounts of bleeding were 2194±1418 mg in the first dental extraction procedure and 2950±1694 mg in the second dental extraction procedure. The median number of used gauze swabs, the median bleeding time, and the mean amount of bleeding were statistically higher in the second dental extraction procedure (p<0.001).Conclusion:Continued warfarin treatment at the time of dental extractions reduces the total amount of bleeding compared with bridging therapy in patients with prosthetic valves.
ObjectiveCryoballoon ablation (CA) is a safe and efficient method for pulmonary vein isolation in the treatment of paroxysmal atrial fibrillation (AF). There are conflicting results about the predictors of AF recurrence. The aim of this study is to evaluate the role of hematological indices to predict AF recurrence after CA.MethodsA total of 49 patients (mean age 58.3±12.2 years, 51.02% female) with symptomatic paroxysmal AF underwent CA procedure. One hundred and sixty-eight pulmonary veins were used for pulmonary vein isolation with the second-generation cryoballoon. The hematological samples were obtained before and 24 hours after ablation.ResultsAt a mean follow-up of 10.2±2.4 months, the probability of being arrhythmia-free after a single procedure was 86%. Patients with AF recurrence had higher red cell distribution width levels (16.10%±1.44% vs 14.87%±0.48%, P=0.035). The neutrophil/lymphocyte ratio, erythrocyte sedimentation rate, and C-reactive protein levels were detected in the patients with or without recurrence. Left atrial diameter (46.28±4.30 mm vs 41.02±4.10 mm, P=0.002), duration of AF (6.71±4.57 years vs 3.59±1.72 years, P=0.003), and age (65.01±15.39 years vs 54.29±11.32 years, P=0.033) were the other independent predictors of clinical recurrence after CA. Multiple regression analysis revealed that left atrial diameter was the only independent predictor for AF recurrence (P=0.012).ConclusionIn this study of patients with paroxysmal AF undergoing cryoablation, increased preablation red cell distribution width levels, and not C-reactive protein or erythrocyte sedimentation rate, was associated with a higher rate of AF recurrence. Our results support the role of a preablation, proinflammatory, and pro-oxidant environment in the development of AF recurrence after ablation therapy but suggest that other factors are also important.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.