2017
DOI: 10.1016/j.amjms.2017.08.010
|View full text |Cite
|
Sign up to set email alerts
|

Combined Cryoballoon and Radiofrequency Ablation Versus Radiofrequency Ablation Alone for Long-Standing Persistent Atrial Fibrillation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(8 citation statements)
references
References 22 publications
0
8
0
Order By: Relevance
“…However, a meta-analysis showed PVI with limited linear ablation within the left atrium significantly reduced AF recurrence while more extensive linear lesion or biatrial ablation not. [ 17 ] Therefore, accurately localizing non-PV foci and limited additional ablation using different ablation strategies such as combined cryoballoon and radiofrequency ablation method [ 18 ] is necessary. In this study, except 2 empirical lines, we also ablate in other non-PV triggers based on the CARTO mapping results because ablation of these triggers maybe benefits.…”
Section: Discussionmentioning
confidence: 99%
“…However, a meta-analysis showed PVI with limited linear ablation within the left atrium significantly reduced AF recurrence while more extensive linear lesion or biatrial ablation not. [ 17 ] Therefore, accurately localizing non-PV foci and limited additional ablation using different ablation strategies such as combined cryoballoon and radiofrequency ablation method [ 18 ] is necessary. In this study, except 2 empirical lines, we also ablate in other non-PV triggers based on the CARTO mapping results because ablation of these triggers maybe benefits.…”
Section: Discussionmentioning
confidence: 99%
“…It is possible that if RF energy applications had been performed at those "silent" areas, the rate of the freedom from AF in Group CB could have been comparable to that of Group RF. In addition, Guler et al demonstrated that CB provided additional substrate modification owing to the balloon and PV mismatch and could provide a lesion formation at the posterior wall of the left atrium, which is the most affected part of left atrium [32] This may have some influence on the results of the present study.…”
Section: Long-term Outcomesmentioning
confidence: 71%
“…The different ablation strategies may influence the risk of recurrent AF and also recurrent stroke. [ 23 25 ]…”
Section: Discussionmentioning
confidence: 99%