Evaluation of image quality (IQ) in Computed Tomography (CT) is important to ensure that diagnostic questions are correctly answered, whilst keeping radiation dose to the patient as low as is reasonably possible. The assessment of individual aspects of IQ is already a key component of routine quality control of medical x-ray devices. These values together with standard dose indicators can be used to give rise to 'figures of merit' (FOM) to characterise the dose efficiency of the CT scanners operating in certain modes. The demand for clinically relevant IQ characterisation has naturally increased with the development of CT technology (detectors efficiency, image reconstruction and processing), resulting in the adaptation and evolution of assessment methods. The purpose of this review is to present the spectrum of various methods that have been used to characterise image quality in CT: from objective measurements of physical parameters to clinically task-based approaches (i.e. model observer (MO) approach) including pure human observer approach. When combined together with a dose indicator, a generalised dose efficiency index can be explored in a framework of system and patient dose optimisation. We will focus on the IQ methodologies that are required for dealing with standard reconstruction, but also for iterative reconstruction algorithms. With this concept the previously used FOM will be presented with a proposal to update them in order to make them relevant and up to date with technological progress. The MO that objectively assesses IQ for clinically relevant tasks represents the most promising method in terms of radiologist sensitivity performance and therefore of most relevance in the clinical environment.
The aim of the guideline presented in this article is to unify the test parameters for image quality evaluation and radiation output in all types of cone-beam computed tomography (CBCT) systems. The applications of CBCT spread over dental and interventional radiology, guided surgery and radiotherapy. The chosen tests provide the means to objectively evaluate the performance and monitor the constancy of the imaging chain. Experience from all involved associations has been collected to achieve a consensus that is rigorous and helpful for the practice. The guideline recommends to assess image quality in terms of uniformity, geometrical precision, voxel density values (or Hounsfield units where available), noise, low contrast resolution and spatial resolution measurements. These tests usually require the use of a phantom and evaluation software. Radiation output can be determined with a kerma-area product meter attached to the tube case. Alternatively, a solid state dosimeter attached to the flat panel and a simple geometric relationship can be used to calculate the dose to the isocentre. Summary tables including action levels and recommended frequencies for each test, as well as relevant references, are provided. If the radiation output or image quality deviates from expected values, or exceeds documented action levels for a given system, a more in depth system analysis (using conventional tests) and corrective maintenance work may be required.
Purpose: We sought to compare objectively computed tomography (CT) scanner performance for three clinically relevant protocols using a task-based image quality assessment method in order to assess the potential for radiation dose reduction. Methods: Four CT scanners released between 2003 and 2007 by different manufacturers were compared with four CT scanners released between 2012 and 2014 by the same manufacturers using ideal linear model observers (MO): prewhitening (PW) MO and channelized Hotelling (CHO) MO with Laguerre-Gauss channels for high-contrast spatial resolution and low-contrast detectability (LCD) performance, respectively. High-contrast spatial resolution was assessed using a custom-made phantom that enabled the computation of the target transfer function (TTF) and noise power spectrum (NPS). Low-contrast detectability was assessed using a commercially available anthropomorphic abdominal phantom providing equivalent diameters of 24, 29.6, and 34.6 cm. Three protocols were reviewed: a head (trauma) and an abdominal (urinary stones) protocol were applied to assess highcontrast spatial resolution performance; and another abdominal (focal liver lesions) protocol was applied for LCD. The liver protocol was tested using fixed and modulated tube currents. The PW MO was proposed for assessing high-contrast detectability performance of the various CT scanners. Results: Compared with older generation CT scanners, three newer systems displayed significant improvements in high-contrast detectability over that of their predecessors. A fourth, newer system had lower performance. The CHO MO was appropriate for assessing LCD performance and revealed that an excellent level of image quality could be obtained with newer scanners at significantly lower dose levels. Conclusions: This study shows that MO can objectively benchmark CT scanners using a task-based image quality method, thus helping to estimate the potential for further dose reductions offered by the latest systems. Such an approach may be useful for adequately and quantitatively comparing clinically relevant image quality among various scanners.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.