Ultrasound induced microbubble cavitation can cause enhanced permeability across natural barriers of tumors such as vessel walls or cellular membranes, allowing for enhanced therapeutic delivery into the target tissues. While enhanced delivery of small (<1 nm) molecules has been shown at acoustic pressures below 1MPa both in vitro and in vivo, the delivery efficiency of larger (>100 nm) therapeutic carriers into cancer remains unclear and may require a higher pressure for sufficient delivery. Enhanced delivery of larger therapeutic carriers such as FDA approved pegylated poly(lactic-co-glycolic acid) nanoparticles (PLGA-PEG-NP) has significant clinical value because these nanoparticles have been shown to protect encapsulated drugs from degradation in the blood circulation and allow for slow and prolonged release of encapsulated drugs at the target location. In this study, various acoustic parameters were investigated to facilitate the successful delivery of two nanocarriers, a fluorescent semiconducting polymer model drug nanoparticle as well as PLGA-PEG-NP into human colon cancer xenografts in mice. We first measured the cavitation dose produced by various acoustic parameters (pressure, pulse length, and pulse repetition frequency) and microbubble concentration in a tissue mimicking phantom. Next, in vivo studies were performed to evaluate the penetration depth of nanocarriers using various acoustic pressures, ranging between 1.7 and 6.9 MPa. Finally, a therapeutic microRNA, miR-122, was loaded into PLGA-PEG-NP and the amount of delivered miR-122 was assessed using quantitative RT-PCR. Our results show that acoustic pressures had the strongest effect on cavitation. An increase of the pressure from 0.8 to 6.9 MPa resulted in a nearly 50-fold increase in cavitation in phantom experiments. In vivo, as the pressures increased from 1.7 to 6.9 MPa, the amount of nanoparticles deposited in cancer xenografts was increased from 4- to 14-fold, and the median penetration depth of extravasated nanoparticles was increased from 1.3-fold to 3-fold, compared to control conditions without ultrasound, as examined on 3D confocal microscopy. When delivering miR-122 loaded PLGA-PEG-NP using optimal acoustic settings with minimum tissue damage, miR-122 delivery into tumors with ultrasound and microbubbles was 7.9-fold higher compared to treatment without ultrasound. This study demonstrates that ultrasound induced microbubble cavitation can be a useful tool for delivery of therapeutic miR loaded nanocarriers into cancer in vivo.
BACKGROUND & AIMS Early detection of pancreatic ductal adenocarcinoma (PDAC) allows for surgical resection and increases patient survival times. Imaging agents that bind and amplify the signal of neovascular proteins in neoplasms can be detected by ultrasound, enabling accurate detection of small lesions. We searched for new markers of neovasculature in PDAC and assessed their potential for tumor detection by ultrasound molecular imaging. METHODS Thymocyte Differentiation Antigen 1 (Thy1) was identified as a specific biomarker of PDAC neovasculature by proteomic analysis. Upregulation in PDAC was validated by immunohistochemical analysis of pancreatic tissue samples from 28 healthy individuals, 15 with primary chronic pancreatitis tissues, and 196 with PDAC. Binding of Thy1-targeted contrast microbubbles was assessed in cultured cells, in mice with orthotopic PDAC xenograft tumors expressing human Thy1 on the neovasculature, and on the neovasculature of a genetic mouse model of PDAC. RESULTS Based on immunohistochemical analyses, levels of Thy1 were significantly higher in the vascular of human PDAC than chronic pancreatitis (P=.007) or normal tissue samples (P<.0001). In mice, ultrasound imaging accurately detected human Thy1-positive PDAC xenografts, as well as PDACs that express endogenous Thy1 in genetic mouse models of PDAC. CONCLUSION We have identified and validated Thy1 as a marker of PDAC that can be detected by ultrasound molecular imaging in mice. The development of a specific imaging agent and identification of Thy1 as a new biomarker could aid in the diagnosis of this cancer and management of patients.
COVID-19 (coronavirus disease 2019) caused by SARS-CoV-2 (severe acute respiratory syndrome coronavirus 2) infection is a disease affecting several organ systems. A model that captures all clinical symptoms of COVID-19 as well as long-haulers disease is needed. We investigated the host responses associated with infection in several major organ systems including the respiratory tract, the heart, and the kidneys after SARS-CoV-2 infection in Syrian hamsters. We found significant increases in inflammatory cytokines (IL-6, IL-1beta, and TNF) and type II interferons whereas type I interferons were inhibited. Examination of extrapulmonary tissue indicated inflammation in the kidney, liver, and heart which also lacked type I interferon upregulation. Histologically, the heart had evidence of myocarditis and microthrombi while the kidney had tubular inflammation. These results give insight into the multiorgan disease experienced by people with COVID-19 and possibly the prolonged disease in people with post-acute sequelae of SARS-CoV-2 (PASC).
Purpose: Breast cancer imaging methods lack diagnostic accuracy, in particular for patients with dense breast tissue, and improved techniques are critically needed. The purpose of this study was to evaluate antibody-indocyanine green (ICG) conjugates, which undergo dynamic absorption spectrum shifts after cellular endocytosis and degradation, and spectroscopic photoacoustic (sPA) imaging to differentiate normal breast tissue from breast cancer by imaging B7-H3, a novel breast cancer associated molecular target.Methods: Quantitative immunohistochemical staining of endothelial and epithelial B7-H3 expression was assessed in 279 human breast tissue samples, including normal (n=53), benign lesions (11 subtypes, n=129), and breast cancers (4 subtypes, n=97). After absorption spectra of intracellular and degraded B7-H3-ICG and Isotype control-ICG (Iso-ICG) were characterized, sPA imaging in a transgenic murine breast cancer model (FVB/N-Tg(MMTVPyMT)634Mul) was performed and compared to imaging of control conditions [B7-H3-ICG in tumor negative animals (n=60), Iso-ICG (n=30), blocking B7-H3+B7-H3-ICG (n=20), and free ICG (n=20)] and validated with ex vivo histological analysis.Results: Immunostaining showed differential B7-H3 expression on both the endothelium and tumor epithelium in human breast cancer with an area under the ROC curve of 0.93 to differentiate breast cancer vs non-cancer. Combined in vitro/in vivo imaging showed that sPA allowed specific B7-H3-ICG detection down to the 13 nM concentration and differentiation from Iso-ICG. sPA molecular imaging of B7-H3-ICG showed a 3.01-fold (P<0.01) increase in molecular B7-H3-ICG signal in tumors compared to control conditions.Conclusions: B7-H3 is a promising target for both vascular and epithelial sPA imaging of breast cancer. Leveraging antibody-ICG contrast agents and their dynamic optical absorption spectra allows for highly specific sPA imaging of breast cancer.
Purpose:To develop and test a molecular imaging approach that uses ultrasonography (US) and a clinically translatable dual-targeted (P-and E-selectin) contrast agent (MB Selectin ) in the quantification of inflammation at the molecular level and to quantitatively correlate selectin-targeted US with fluorodeoxyglucose (FDG) combined positron emission tomography (PET) and computed tomography (CT) in terms of visualization and quantification of different levels of inflammation in a murine acute colitis model. Materials and Methods:Animal studies were approved by the Institutional Admin- Results:MB Selectin showed strong attachment to both human and mouse P-and E-selectin compared with MB Control in vitro (P .002). In vivo, US signal was significantly increased (P , .001) in mice with acute colitis (173.8 arbitrary units [au] 6 134.8 [standard deviation]) compared with control mice (5.0 au 6 4.5). US imaging signal strongly correlated with FDG uptake on PET/CT images (r = 0.89, P , .001). Ex vivo analysis enabled confirmation of inflammation in mice with acute colitis and high expression levels of P-and E-selectin in mucosal capillaries (P = .014). Conclusion:US with MB Selectin specifically enables detection and quantification of inflammation in a murine acute colitis model, leveraging the natural pathway of leukocyte recruitment in inflammatory tissue. US imaging with MB Selectin correlates well with FDG uptake at PET/CT imaging.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.