Continued development of computational models and biofidelic anthropomorphic test devices (ATDs) necessitates further analysis of the effects of bracing on an occupant's biomechanical response in automobile collisions. A total of 20 dynamic sled tests were performed, 10 low (2.5 g, Δv = 4.8 kph) and 10 medium severity (5.0 g, Δv = 9.7 kph), with five male human volunteers of approximately 50th percentile male height and weight. Each volunteer was exposed to two impulses at each severity, one relaxed and one braced prior to the impulse. A Vicon motion analysis system, 12 MX-T20 2 megapixel cameras, was used to quantify subject 3D kinematics (±1 mm) (1 kHz). Excursions of select anatomical regions were normalized to their respective initial positions and compared by test condition. At the low severity, bracing significantly reduced (p < 0.05) the forward excursion of the knees, hips, elbows, shoulders, and head (average 35-70%). At the medium severity, bracing significantly reduced (p < 0.05) the forward excursion of the elbows, shoulders, and head (average 36-69%). Although not significant, bracing at the medium severity considerably reduced the forward excursion of the knees and hips (average 18-26%). This study illustrates that bracing has a significant influence on the biomechanical response of human occupants in frontal sled tests and provides novel biomechanical data that can be used to refine and validate computational models and ATDs used to assess injury risk in automotive collisions.
This study examined the effects of active muscles, in the form of conscious and reflexive muscle activity, on the biomechanical response of occupants in low-speed frontal sled tests. Although active bracing did not result in significantly different peak neck loads or moments, the timing of these peak values were affected by muscle condition. The findings of this study provide insight to the kinetics experienced during low-speed sled tests and are important to consider when refining and validating computational models and ATDs used to assess injury risk in automotive collisions.
Ms Alphonse had full access to all of the data in the study and takes responsibility for the integrity of the data and the accuracy of the data analysis.
The data from the current study showed that both KBABs and SWABs affected the kinematics of all surrogates during frontal sled tests. The results of the objective rating analysis indicated that the HIII and THOR-M had comparable overall biofidelity scores. The THOR-M slightly outperformed the HIII for the acceleration and angular velocity data. However, the HIII scored slightly better than the THOR-M for the excursion data. The most notable difference in biofidelity was for the knee excursions, where the HIII had a much higher average ISO score. Only the biofidelity of the HIII and THOR-M with regard to occupant kinematics was evaluated in this study; therefore, future work will evaluate the biofidelity of the ATDs in terms of lower extremity loading, thoracic response, and neck loading.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.