A multi-class and multi-residue/contaminant method for the determination of veterinary drug and pesticide residues and mycotoxins in bovine meat has been developed and validated. The veterinary drug residues/contaminants included antimicrobials, anabolic hormones, lactones, β-agonists, mycotoxins, and pesticides. Isotopic labeled internal standards were included to compensate residual matrix effects. The calibrators used in the method demonstrated linearity with the R2 > 0.98. The decision limit (CCα) values were in the range from 0.067 to 2103.84 μg/kg, while the range for detection capability (CCβ) was from 0.083 to 2482.13 μg/kg. The limit of detection (LOD) and limit of quantification (LOQ) were in the range from 0.059 to 291.36 μg/kg, and 0.081 to 328.13 μg/kg, respectively. The recovery of analytes ranged from 61.28% to 116.20%. The intra-day coefficient of variation (CV) was from 0.97 to 25.93% and the inter-day CV was 2.30–34.04%. The method has been used for the determination of 49 residues/contaminants in bovine meat. Application of the method in routine analysis in bovine samples, revealed in limited samples the presences of enrofloxacin, oxytetracycline and sulfadiazine at the concentration of 35.22 µg/kg, 27.35 µg/kg, and 36.20 µg/kg, respectively.
Introduction
Multi-class and multi-residue analyses are very complex procedures because of the physico-chemical properties of veterinary drug residues and other contaminants. The purpose of the study was to develop an analytical method for the sensitive determination of 69 analytes in bovine milk by liquid chromatography electrospray ionisation–tandem mass spectrometry.
Material and Methods
Antimicrobial, anabolic hormone, lactone, β-agonist, mycotoxin and pesticide residues were analysed in 120 raw milk samples from different dairy farms in North Macedonia. Stable isotopically labelled internal standards were used to facilitate effective quantification of the analytes.
Results
The linear regression coefficients were higher than 0.99, the limits of detection ranged from 0.0036 to 47.94 μg/L, and the limits of quantification ranged from 0.053 to 59.43 μg/L. The decision limit values ranged from 0.062 to 211.32 μg/L and the detection capability from 0.080 to 233.71 μg/L. Average recoveries of the analytes spiked in raw milk were in the range of 70.83% to 109%, intra-day coefficient of variation (CV) values from 2.41% to 22.29%, and inter-day CV values from 3.48% to 23.91%. The method was successfully applied in the testing of bovine milk samples. In five samples residues were detected. They were sulfadimethoxine (in two samples), enrofloxacin, tetracycline and oxytetracycline and were at concentrations below the EU maximum residue limit.
Conclusion
The method is useful for routine testing for this group of chemical hazards in bovine milk.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.