Kinematic alignment (KA) is an alternative philosophy for aligning a total knee replacement (TKR) which aims to restore all three kinematic axes of the native knee. Many of the studies on KA have actually described non-KA techniques, which has led to much confusion about what actually fits the definition of KA. Alignment should only be measured using three-dimensional cross-sectional imaging. Many of the studies looking at the influence of implants/limb alignment on total knee arthroplasty outcomes are of limited value because of the use of two-dimensional imaging to measure alignment, potentially leading to inaccuracy. No studies have shown KA to be associated with higher complication rates or with worse implant survival; and the clinical outcomes following KA tend to be at least as good as mechanical alignment. Further high-quality multi-centre randomized controlled trials are needed to establish whether KA provides better function and without adversely impacting implant survival. Cite this article: EFORT Open Rev 2020;5:380-390. DOI: 10.1302/2058-5241.5.200010
Background
On the 11th March 2020, the World Health Organization declared the COVID-19 outbreak a pandemic. Multiple new guidelines were proposed and existing models of social, domestic and hospital care altered. Most healthcare systems were largely unprepared for this, and the pandemic has tested their adaptability. This study aimed to assess the impact of COVID-19 on the demographics, presentation, clinical management and outcomes of patients with proximal femoral (hip) fractures comparing them to a similar cohort of patients admitted a year earlier.
Methods
This retrospective multi-centre cohort study compared all patients admitted with hip fractures between 1st March and 30th May 2019 (group PC: pre-COVID-19) with hip fracture patients admitted over the same time period during the pandemic in 2020 (group C: COVID-19). The data was obtained from the hospitals’ local and National Hip Fracture Databases. Mortality data was checked with the Office for National Statistics (ONS). Primary outcomes were time to theatre, in-patient length of stay and 30-day mortality.
Results
A total of 580 patients were included (304 group PC, 276 group C). Patient demographics including Charlson Comorbidity Index and Nottingham Hip Fracture Scores were broadly similar across the two cohorts. There was a significant reduction in the percentage of total hip replacements (11 to 5%, p = 0.006) in group C. There was an increase in conservative management (1 to 5%, p = 0.002) in group C. Time to theatre was significantly delayed in group C (43.7 h) vs group PC (34.6 h) (p ≤ 0.001). The overall length of hospital stay was significantly longer in group PC (16.6 days) vs group C (15 days) (p = 0.025). The 30-day mortality rate in group C was 9.8% compared to 8.2% in group PC (p = 0.746), but for COVID-19 (+) patients, it was significantly higher at 38.2% vs 5.8% in COVID-19 (−) patients (p < 0.001).
Conclusion
This is one of the largest multi-centre comparative cohort study in the literature to date examining the impact of the COVID-19 pandemic on the management of hip fracture patients. Whilst mortality rates were similar in both groups, COVID-19-positive patients were almost seven times more likely to die, reflecting the seriousness of the COVID-19 infection and its sequelae in such elderly, vulnerable patients.
ABSTRACT:Nanoscale reversed-phase liquid chromatography (LC) combined with electrospray ionization-tandem mass spectrometry (ESI-MS/ MS) has been used as a method for the direct identification of multiple cytochrome P450 (P450) isoforms found in male and female rat liver. In this targeted proteomic approach, rat liver microsomes were subjected to sodium dodecyl sulfate-polyacrylamide gel electrophoresis followed by in-gel tryptic digestion of the proteins present in the 48-to 62-kDa bands. The resultant peptides were extracted and analyzed by LC-ESI-MS/MS. P450 identifications were made by searching the MS/MS data against a rat protein database containing 21,576 entries including 47 P450s using Sequest software (Thermo Electron, Hemel Hempstead, UK). Twentyfour P450 isoforms from the subfamilies 1A, 2A, 2B, 2C, 2D, 2E, 3A, 4A, 4F, CYP17, and CYP19 were positively identified in rat liver.
Purpose
The purpose of this study was to perform a systematic review and meta-analysis to compare clinical and patient-reported outcome measures of medially stabilised (MS) TKA when compared to other TKA designs.
Methods
The Preferred Reporting Items for Systematic Review and Meta-Analyses algorithm was used. The Cochrane Central Register of Controlled Trials, MEDLINE, EMBASE, and EMCARE databases were searched to June 2020. Studies with a minimum of 12 months of follow-up comparing an MS TKA design to any other TKA design were included. The statistical analysis was completed using Review Manager (RevMan), Version 5.3.
Results
The 22 studies meeting the inclusion criteria included 3011 patients and 4102 TKAs. Overall Oxford Knee Scores were significantly better (p = 0.0007) for MS TKA, but there was no difference in the Forgotten Joint Scores (FJS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Knee Society Score (KSS)-Knee, KSS-Function, and range of motion between MS and non-MS TKA designs. Significant differences were noted for sub-group analyses; MS TKA showed significantly worse KSS-Knee (p = 0.02) and WOMAC (p = 0.03) scores when compared to Rotating Platform (RP) TKA while significantly better FJS (p = 0.002) and KSS-knee scores (p = 0.0001) when compared to cruciate-retaining (CR) TKA.
Conclusion
This review and meta-analysis show that MS TKA designs result in both patient and clinical outcomes that are comparable to non-MS implants. These results suggest implant design alone may not provide further improvement in patient outcome following TKA, surgeons must consider other factors, such as alignment to achieve superior outcomes.
Level of evidence
III.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.