Main RecommendationsESGE recommends the use of a graded pneumatic dilation protocol in achalasia, starting with a 30-mm dilation and followed by a 35-mm dilation at a planned interval of 2 – 4 weeks, with a subsequent 40-mm dilation when there is insufficient relief, over both a single balloon dilation procedure or the use of a larger balloon from the outset.Strong recommendation, high quality of evidence, level of agreement 100 %.ESGE recommends being cautious in treating spastic motility disorders other than achalasia with peroral endoscopic myotomy (POEM).Strong recommendation, very low quality of evidence, level of agreement 87.5 %.ESGE recommends against the routine use of botulinum toxin injections to treat patients with non-achalasia hypercontractile esophageal motility disorders (Jackhammer esophagus, distal esophageal spasm). However, if, in individual patients, endoscopic injection of botulinum toxin is chosen, ESGE recommends performing injections into four quadrants of the lower esophageal sphincter and in the lower third of the esophagus.Strong recommendation, low quality of evidence, level of agreement 78.6 %.ESGE recommends that endoscopic pylorus-directed therapy should be considered only in patients with symptoms suggestive of gastroparesis in combination with objective proof of delayed gastric emptying using a validated test, and only when medical therapy has failed.Strong recommendation, very low quality of evidence, level of agreement 100 %.ESGE recommends against the use of botulinum toxin injection in the treatment of unselected patients with gastroparesis. Strong recommendation, high quality of evidence, level of agreement 92.9 %.ESGE recommends consideration of gastric peroral endoscopic myotomy (G-POEM) in carefully selected patients only, because it is an emerging procedure with limited data on effectiveness, safety, and durability. G-POEM should be performed in expert centers only, preferably in the context of a clinical trial.Strong recommendation, low quality of evidence, level of agreement 100 %.
Surveillance for hepatocellular carcinoma was associated with smaller tumor size, earlier tumor stage, with an impact on therapeutic strategy and was an independent predictor of survival.
The prognosis for patients with propionic acidaemia appeared to be satisfactory in terms of survival and outcome characteristics such as neurological and mental development. Despite these results the authors feel that the prognosis and quality of life of these patients might be improved with liver transplantation or possibly somatic gene therapy in the future.
Imaging has become an essential tool in modern radiotherapy (RT), being used to plan dose delivery prior to treatment and verify target position before and during treatment. Ultrasound (US) imaging is cost-effective in providing excellent contrast at high resolution for depicting soft tissue targets apart from those shielded by the lungs or cranium. As a result, it is increasingly used in RT setup verification for the measurement of inter-fraction motion, the subject of Part I of this review (Fontanarosa et al 2015 Phys. Med. Biol. 60 R77-114). The combination of rapid imaging and zero ionising radiation dose makes US highly suitable for estimating intra-fraction motion. The current paper (Part II of the review) covers this topic. The basic technology for US motion estimation, and its current clinical application to the prostate, is described here, along with recent developments in robust motion-estimation algorithms, and three dimensional (3D) imaging. Together, these are likely to drive an increase in the number of future clinical studies and the range of cancer sites in which US motion management is applied. Also reviewed are selections of existing and proposed novel applications of US imaging to RT. These are driven by exciting developments in structural, functional and molecular US imaging and analytical techniques such as backscatter tissue analysis, elastography, photoacoustography, contrast-specific imaging, dynamic contrast analysis, microvascular and super-resolution imaging, and targeted microbubbles. Such techniques show promise for predicting and measuring the outcome of RT, quantifying normal tissue toxicity, improving tumour definition and defining a biological target volume that describes radiation sensitive regions of the tumour. US offers easy, low cost and efficient integration of these techniques into the RT workflow. US contrast technology also has potential to be used actively to assist RT by manipulating the tumour cell environment and by improving the delivery of radiosensitising agents. Finally, US imaging offers various ways to measure dose in 3D. If technical problems can be overcome, these hold potential for wide-dissemination of cost-effective pre-treatment dose verification and in vivo dose monitoring methods. It is concluded that US imaging could eventually contribute to all aspects of the RT workflow.
In modern radiotherapy, verification of the treatment to ensure the target receives the prescribed dose and normal tissues are optimally spared has become essential. Several forms of image guidance are available for this purpose. The most commonly used forms of image guidance are based on kilovolt or megavolt x-ray imaging. Image guidance can also be performed with non-harmful ultrasound (US) waves. This increasingly used technique has the potential to offer both anatomical and functional information.This review presents an overview of the historical and current use of two-dimensional and three-dimensional US imaging for treatment verification in radiotherapy. The US technology and the implementation in the radiotherapy workflow are described. The use of US guidance in the treatment planning process is discussed. The role of US technology in inter-fraction motion monitoring and management is explained, and clinical studies of applications in areas such as the pelvis, abdomen and breast are reviewed. A companion review paper (O'Shea et al 2015 Phys. Med. Biol. submitted) will extensively discuss the use of US imaging for intra-fraction motion quantification and novel applications of US technology to RT.
Main RecommendationsESGE suggests flexible endoscopic treatment over open surgical treatment as first-line therapy for patients with a symptomatic Zenker’s diverticulum of any size.Weak recommendation, low quality of evidence, level of agreement 100 %.ESGE recommends that emerging treatments for Zenker’s diverticulum, such as Zenker’s peroral endoscopic myotomy (Z-POEM) and tunneling, be considered as experimental; these treatments should be offered in a research setting only.Strong recommendation, low quality of evidence, level of agreement 100 %.ESGE recommends against the widespread clinical use of transoral incisionless fundoplication (TIF) as an alternative to proton pump inhibitor (PPI) therapy or antireflux surgery in the treatment of gastroesophageal reflux disease (GERD), because of the lack of data on the long-term outcomes, the inferiority of TIF to fundoplication, and its modest efficacy in only highly selected patients. TIF may have a role for patients with mild GERD who are not willing to take PPIs or undergo antireflux surgery.Strong recommendation, moderate quality of evidence, level of agreement 92.8 %.ESGE recommends against the use of the Medigus ultrasonic surgical endostapler (MUSE) in clinical practice because of insufficient data showing its effectiveness and safety in patients with GERD. MUSE should be used in clinical trials only.Strong recommendation, low quality evidence, level of agreement 100 %.ESGE recommends against the use of antireflux mucosectomy (ARMS) in routine clinical practice in the treatment of GERD because of the lack of data and its potential complications.Strong recommendation, low quality evidence, level of agreement 100 %.ESGE recommends endoscopic cecostomy only after conservative management with medical therapies or retrograde lavage has failed.Strong recommendation, low quality evidence, level of agreement 93.3 %.ESGE recommends fixing the cecum to the abdominal wall at three points (using T-anchors, a double-needle suturing device, or laparoscopic fixation) to prevent leaks and infectious adverse events, whatever percutaneous endoscopic cecostomy method is used.Strong recommendation, very low quality evidence, level of agreement 86.7 %.ESGE recommends considering endoscopic decompression of the colon in patients with Ogilvie’s syndrome that is not improving with conservative treatment.Strong recommendation, low quality evidence, level of agreement 93.8 %.ESGE recommends prompt endoscopic decompression if the cecal diameter is > 12 cm and if the Ogilvie’s syndrome exists for a duration of longer than 4 – 6 days.Strong recommendation, low quality evidence, level of agreement 87.5 %.
The students' learning activities covered an average of 64% of the intended course content; in addition, the students generated learning issues not expected by the faculty, and half of these issues were judged relevant to the course content. Thus, PBL seems to permit students to adapt learning activities to their own needs and interests.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.