2016
DOI: 10.1088/0031-9155/61/8/r90
|View full text |Cite
|
Sign up to set email alerts
|

Review of ultrasound image guidance in external beam radiotherapy part II: intra-fraction motion management and novel applications

Abstract: Imaging has become an essential tool in modern radiotherapy (RT), being used to plan dose delivery prior to treatment and verify target position before and during treatment. Ultrasound (US) imaging is cost-effective in providing excellent contrast at high resolution for depicting soft tissue targets apart from those shielded by the lungs or cranium. As a result, it is increasingly used in RT setup verification for the measurement of inter-fraction motion, the subject of Part I of this review (Fontanarosa et al… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
75
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 83 publications
(75 citation statements)
references
References 345 publications
(262 reference statements)
0
75
0
Order By: Relevance
“…Colvill et al studied the dosimetric impact of tracking and gating to account for intrafraction motion during prostate radiotherapy [22]. O’Shea et al reviewed the applicability of intrafraction monitoring with US for prostate and other treatment sites [23]. Until further results on the practicability and accuracy of TPUS are available, certainly the combination of setup verification by CBCT and intrafraction target organ and OAR motion monitoring by TPUS imaging can use the benefits of both imaging modalities.…”
Section: Discussionmentioning
confidence: 99%
“…Colvill et al studied the dosimetric impact of tracking and gating to account for intrafraction motion during prostate radiotherapy [22]. O’Shea et al reviewed the applicability of intrafraction monitoring with US for prostate and other treatment sites [23]. Until further results on the practicability and accuracy of TPUS are available, certainly the combination of setup verification by CBCT and intrafraction target organ and OAR motion monitoring by TPUS imaging can use the benefits of both imaging modalities.…”
Section: Discussionmentioning
confidence: 99%
“…using ultrasound [40] to remove correlation errors altogether), and the online integration of the 4D EDC during CyberKnife treatment.…”
Section: A C C E P T E D Accepted Manuscriptmentioning
confidence: 99%
“…Whilst the advantages of using real-time US to guide the delivery of RT are clear, 8 very little is still known about the effect of the US probe on the radiation dose delivered to the patient. For example Hsu et al (2005) pointed out that work remains to be done on the effect of the probe on surface dose when examining the feasibility of utilizing transabdominal US for real-time monitoring of target motion in RT.…”
Section: Introductionmentioning
confidence: 99%