SummaryBackgroundStudies evaluating titration of antihypertensive medication using self-monitoring give contradictory findings and the precise place of telemonitoring over self-monitoring alone is unclear. The TASMINH4 trial aimed to assess the efficacy of self-monitored blood pressure, with or without telemonitoring, for antihypertensive titration in primary care, compared with usual care.MethodsThis study was a parallel randomised controlled trial done in 142 general practices in the UK, and included hypertensive patients older than 35 years, with blood pressure higher than 140/90 mm Hg, who were willing to self-monitor their blood pressure. Patients were randomly assigned (1:1:1) to self-monitoring blood pressure (self-montoring group), to self-monitoring blood pressure with telemonitoring (telemonitoring group), or to usual care (clinic blood pressure; usual care group). Randomisation was by a secure web-based system. Neither participants nor investigators were masked to group assignment. The primary outcome was clinic measured systolic blood pressure at 12 months from randomisation. Primary analysis was of available cases. The trial is registered with ISRCTN, number ISRCTN 83571366.Findings1182 participants were randomly assigned to the self-monitoring group (n=395), the telemonitoring group (n=393), or the usual care group (n=394), of whom 1003 (85%) were included in the primary analysis. After 12 months, systolic blood pressure was lower in both intervention groups compared with usual care (self-monitoring, 137·0 [SD 16·7] mm Hg and telemonitoring, 136·0 [16·1] mm Hg vs usual care, 140·4 [16·5]; adjusted mean differences vs usual care: self-monitoring alone, −3·5 mm Hg [95% CI −5·8 to −1·2]; telemonitoring, −4·7 mm Hg [–7·0 to −2·4]). No difference between the self-monitoring and telemonitoring groups was recorded (adjusted mean difference −1·2 mm Hg [95% CI −3·5 to 1·2]). Results were similar in sensitivity analyses including multiple imputation. Adverse events were similar between all three groups.InterpretationSelf-monitoring, with or without telemonitoring, when used by general practitioners to titrate antihypertensive medication in individuals with poorly controlled blood pressure, leads to significantly lower blood pressure than titration guided by clinic readings. With most general practitioners and many patients using self-monitoring, it could become the cornerstone of hypertension management in primary care.FundingNational Institute for Health Research via Programme Grant for Applied Health Research (RP-PG-1209-10051), Professorship to RJM (NIHR-RP-R2-12-015), Oxford Collaboration for Leadership in Applied Health Research and Care, and Omron Healthcare UK.
BackgroundHome blood-pressure (BP) monitoring is recommended in guidelines and is increasingly popular with patients and health professionals, but the accuracy of patients’ own monitors in real-world use is not known.AimTo assess the accuracy of home BP monitors used by people with hypertension, and to investigate factors affecting accuracy.Design and settingCross-sectional, observational study in urban and suburban settings in central England.MethodPatients (n = 6891) on the hypertension register at seven practices in the West Midlands, England, were surveyed to ascertain whether they owned a BP monitor and wanted it tested. Monitor accuracy was compared with a calibrated reference device at 50 mmHg intervals between 0–280/300 mmHg (static pressure test); a difference from the reference monitor of +/−3 mmHg at any interval was considered a failure. Cuff performance was also assessed. Results were analysed by frequency of use, length of time in service, make and model, monitor validation status, purchase price, and any previous testing.ResultsIn total, 251 (76%, 95% confidence interval [95% CI] = 71 to 80%) of 331 tested devices passed all tests (monitors and cuffs), and 86% (CI] = 82 to 90%) passed the static pressure test; deficiencies were, primarily, because of monitors overestimating BP. A total of 40% of testable monitors were not validated. The pass rate on the static pressure test was greater in validated monitors (96%, 95% CI = 94 to 98%) versus unvalidated monitors (64%, 95% CI = 58 to 69%), those retailing for >£10 (90%, 95% CI = 86 to 94%), those retailing for ≤£10 (66%, 95% CI = 51 to 80%), those in use for ≤4 years (95%, 95% CI = 91 to 98%), and those in use for >4 years (74%, 95% CI = 67 to 82%). All in all, 12% of cuffs failed.ConclusionPatients’ own BP monitor failure rate was similar to that demonstrated in studies performed in professional settings, although cuff failure was more frequent. Clinicians can be confident of the accuracy of patients’ own BP monitors if the devices are validated and ≤4 years old.
BackgroundSelf-monitoring of hypertension is associated with lower systolic blood pressure (SBP). However, evidence for the use of self-monitoring to titrate antihypertensive medication by physicians is equivocal. Furthermore, there is some evidence for the efficacy of telemonitoring in the management of hypertension but it is not clear what this adds over and above self-monitoring. This trial aims to evaluate whether GP led antihypertensive titration using self-monitoring results in lower SBP compared to usual care and whether telemonitoring adds anything to self-monitoring alone.Methods/DesignThis will be a pragmatic primary care based, unblinded, randomised controlled trial of self-monitoring of BP with or without telemonitoring compared to usual care. Eligible patients will have poorly controlled hypertension (>140/90 mmHg) and will be recruited from primary care. Participants will be individually randomised to either usual care, self-monitoring alone, or self-monitoring with telemonitoring. The primary outcome of the trial will be difference in clinic SBP between intervention and control groups at 12 months adjusted for baseline SBP, gender, BP target and practice. At least 1110 patients will be sufficient to detect a difference in SBP between self-monitoring with or without telemonitoring and usual care of 5 mmHg with 90% power with an adjusted alpha of 0.017 (2-sided) to adjust for all three pairwise comparisons. Other outcomes will include adherence of anti-hypertensive medication, lifestyle behaviours, health-related quality of life, and adverse events. An economic analysis will consider both within trial costs and a model extrapolating the results thereafter. A qualitative sub study will gain insights into the views, experiences and decision making processes of patients and health care professionals focusing on the acceptability of self-monitoring and telemonitoring in the routine management of hypertension.DiscussionThe results of the trial will be directly applicable to primary care in the UK. If successful, self-monitoring of BP in people with hypertension would be applicable to hundreds of thousands of individuals in the UK.Trial registration ISRCTN 83571366. Registered 17 July 2014
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.