SummaryBackgroundStudies evaluating titration of antihypertensive medication using self-monitoring give contradictory findings and the precise place of telemonitoring over self-monitoring alone is unclear. The TASMINH4 trial aimed to assess the efficacy of self-monitored blood pressure, with or without telemonitoring, for antihypertensive titration in primary care, compared with usual care.MethodsThis study was a parallel randomised controlled trial done in 142 general practices in the UK, and included hypertensive patients older than 35 years, with blood pressure higher than 140/90 mm Hg, who were willing to self-monitor their blood pressure. Patients were randomly assigned (1:1:1) to self-monitoring blood pressure (self-montoring group), to self-monitoring blood pressure with telemonitoring (telemonitoring group), or to usual care (clinic blood pressure; usual care group). Randomisation was by a secure web-based system. Neither participants nor investigators were masked to group assignment. The primary outcome was clinic measured systolic blood pressure at 12 months from randomisation. Primary analysis was of available cases. The trial is registered with ISRCTN, number ISRCTN 83571366.Findings1182 participants were randomly assigned to the self-monitoring group (n=395), the telemonitoring group (n=393), or the usual care group (n=394), of whom 1003 (85%) were included in the primary analysis. After 12 months, systolic blood pressure was lower in both intervention groups compared with usual care (self-monitoring, 137·0 [SD 16·7] mm Hg and telemonitoring, 136·0 [16·1] mm Hg vs usual care, 140·4 [16·5]; adjusted mean differences vs usual care: self-monitoring alone, −3·5 mm Hg [95% CI −5·8 to −1·2]; telemonitoring, −4·7 mm Hg [–7·0 to −2·4]). No difference between the self-monitoring and telemonitoring groups was recorded (adjusted mean difference −1·2 mm Hg [95% CI −3·5 to 1·2]). Results were similar in sensitivity analyses including multiple imputation. Adverse events were similar between all three groups.InterpretationSelf-monitoring, with or without telemonitoring, when used by general practitioners to titrate antihypertensive medication in individuals with poorly controlled blood pressure, leads to significantly lower blood pressure than titration guided by clinic readings. With most general practitioners and many patients using self-monitoring, it could become the cornerstone of hypertension management in primary care.FundingNational Institute for Health Research via Programme Grant for Applied Health Research (RP-PG-1209-10051), Professorship to RJM (NIHR-RP-R2-12-015), Oxford Collaboration for Leadership in Applied Health Research and Care, and Omron Healthcare UK.
The use of self-monitoring of blood pressure, with or without telemonitoring, to guide therapy decisions by physicians for patients with hypertension has been recently demonstrated to reduce blood pressure compared with using clinic monitoring (usual care). However, both the cost-effectiveness of these strategies compared with usual care, and whether the additional benefit of telemonitoring compared with self-monitoring alone could be considered value for money, are unknown. This study assessed the cost-effectiveness of physician titration of antihypertensive medication using self-monitored blood pressure, with or without telemonitoring, to make hypertension treatment decisions in primary care compared with usual care. A Markov patient-level simulation model was developed taking a UK Health Service/Personal Social Services perspective. The model adopted a lifetime time horizon with 6-month time cycles. At a willingness to pay of £20 000 per quality-adjusted life year, self-monitoring plus telemonitoring was the most cost-effective strategy (£17 424 per quality-adjusted life year gained) compared with usual care or self-monitoring alone (posting the results to the physician). However, deterministic sensitivity analysis showed that self-monitoring alone became the most cost-effective option when changing key assumptions around long-term effectiveness and time horizon. Overall, probabilistic sensitivity analysis suggested that self-monitoring regardless of transmission modality was likely to be cost-effective compared with usual care (89% probability of cost-effectiveness at £20 000/quality-adjusted life year), with high uncertainty as to whether telemonitoring or self-monitoring alone was the most cost-effective option. Self-monitoring in clinical practice is cost-effective and likely to lead to reduced cardiovascular mortality and morbidity.
BackgroundSelf-monitoring of blood pressure is common but how telemonitoring with a mobile healthcare (mHealth) solution in the management of hypertension can be implemented by patients and healthcare professionals (HCPs) is currently unclear.AimEvaluation of facilitators and barriers to self- and telemonitoring interventions for hypertension within the Telemonitoring and Self-monitoring in Hypertension (TASMINH4) trial.Design and settingAn embedded process evaluation of the TASMINH4 randomised controlled trial (RCT), in the West Midlands, in UK primary care, conducted between March 2015 and September 2016.MethodA total of 40 participants comprising 23 patients were randomised to one of two arms: mHealth (self-monitoring by free text/short message service [SMS]) and self-monitoring without mHealth (self-monitoring using paper diaries). There were also15 healthcare professionals (HCPs) and two patient caregivers.ResultsFour key implementation priority areas concerned: acceptability of self- and telemonitoring to patients and HCPs; managing data; communication; and integrating self-monitoring into hypertension management (structured care). Structured home monitoring engaged and empowered patients to self-monitor regardless of the use of mHealth, whereas telemonitoring potentially facilitated more rapid communication between HCPs and patients. Paper-based recording integrated better into current workflows but required additional staff input.ConclusionAlthough telemonitoring by mHealth facilitates easier communication and convenience, the realities of current UK general practice meant that a paper-based approach to self-monitoring could be integrated into existing workflows with greater ease. Self-monitoring should be offered to all patients with hypertension. Telemonitoring appears to give additional benefits to practices over and above self-monitoring but both need to be offered to ensure generalisability.
BACKGROUNDSelf-monitoring of blood pressure better predicts prognosis than clinic measurement, is popular with patients, and endorsed in hypertension guidelines. However, there is uncertainty over the optimal self-monitoring schedule. We therefore aimed to determine the optimum schedule to predict future cardiovascular events and determine “true” underlying blood pressure.METHODSSix electronic databases were searched from November 2009 (updating a National Institute for Health and Care Excellence [NICE] systematic review) to April 2017. Studies that compared aspects of self-monitoring schedules to either prognosis or reliability/reproducibility in hypertensive adults were included. Data on study and population characteristics, self-monitoring regime, and outcomes were extracted by 2 reviewers independently.RESULTSFrom 5,164 unique articles identified, 25 met the inclusion criteria. Twelve studies were included from the original NICE review, making a total of 37 studies. Increasing the number of days of measurement improved prognostic power: 72%–91% of the theoretical maximum predictive value (asymptotic maximum hazard ratio) was reached by 3 days and 86%–96% by 7 days. Increasing beyond 3 days of measurement did not result in better correlation with ambulatory monitoring. There was no convincing evidence that the timing or number of readings per day had an effect, or that ignoring the first day’s measurement was necessary.CONCLUSIONSHome blood pressure should be measured for 3 days, increased to 7 only when mean blood pressure is close to a diagnostic or treatment threshold. Other aspects of a monitoring schedule can be flexible to facilitate patient uptake of and adherence with self-monitoring.
BackgroundHome blood-pressure (BP) monitoring is recommended in guidelines and is increasingly popular with patients and health professionals, but the accuracy of patients’ own monitors in real-world use is not known.AimTo assess the accuracy of home BP monitors used by people with hypertension, and to investigate factors affecting accuracy.Design and settingCross-sectional, observational study in urban and suburban settings in central England.MethodPatients (n = 6891) on the hypertension register at seven practices in the West Midlands, England, were surveyed to ascertain whether they owned a BP monitor and wanted it tested. Monitor accuracy was compared with a calibrated reference device at 50 mmHg intervals between 0–280/300 mmHg (static pressure test); a difference from the reference monitor of +/−3 mmHg at any interval was considered a failure. Cuff performance was also assessed. Results were analysed by frequency of use, length of time in service, make and model, monitor validation status, purchase price, and any previous testing.ResultsIn total, 251 (76%, 95% confidence interval [95% CI] = 71 to 80%) of 331 tested devices passed all tests (monitors and cuffs), and 86% (CI] = 82 to 90%) passed the static pressure test; deficiencies were, primarily, because of monitors overestimating BP. A total of 40% of testable monitors were not validated. The pass rate on the static pressure test was greater in validated monitors (96%, 95% CI = 94 to 98%) versus unvalidated monitors (64%, 95% CI = 58 to 69%), those retailing for >£10 (90%, 95% CI = 86 to 94%), those retailing for ≤£10 (66%, 95% CI = 51 to 80%), those in use for ≤4 years (95%, 95% CI = 91 to 98%), and those in use for >4 years (74%, 95% CI = 67 to 82%). All in all, 12% of cuffs failed.ConclusionPatients’ own BP monitor failure rate was similar to that demonstrated in studies performed in professional settings, although cuff failure was more frequent. Clinicians can be confident of the accuracy of patients’ own BP monitors if the devices are validated and ≤4 years old.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.