Calcium hydroxide apexification and Mineral Trioxide Aggregate (MTA) apexification are classical treatments for necrotic immature permanent teeth. The first tend to fail for lack of compliance given the high number of sessions needed; the second has technical difficulties such as material manipulation and overfilling. With both techniques, the root development is interrupted leaving the tooth with a fragile root structure, a poor crown-to-root ratio, periodontal breakdown, and high risk of fracture, compromising long-term prognosis of the tooth. New scientific literature has described a procedure that allows complete root development of these specific teeth. This regenerative endodontic procedure (REP) proposes the use of a combination of antimicrobials and irrigants, no canal walls instrumentation, induced apical bleeding to form a blood clot and a tight seal into the root canal to promote healing. MTA is the most used material to perform this seal, but updated guidelines advise the use of other bioactive endodontic cements that incorporate calcium and silicate in their compositions. They share most of their characteristics with MTA but claim to have fewer drawbacks with regards to manipulation and aesthetics. The purpose of the present article is to review pertinent literature and to describe the clinical procedures protocol with its variations, and their clinical application.
ObjectiveTo evaluate the efficacy of different sonic and ultrasonic devices in the elimination of debris from canal irregularities in artificial root canals.Materials and MethodsA resin model of a transparent radicular canal filled with dentin debris was used. Five groups were tested, namely: Group 1 – ultrasonic insert 15.02; Group 2 – ultrasonic insert 25/25 IRRI K; Group 3 – ultrasonic insert 25/25 IRRI S; Group 4 – sonic insert 20/28 Eddy on a vibrating sonic air-scaler handpiece; Group 5 – 20.02 K-file inserted on a Safety M4 handpiece. Two different irrigants (5% sodium hypochlorite and 17% EDTA) and 3 different times of activation (20, 40, and 60 seconds) were tested. Means and standard deviations were calculated and statistically analyzed with the Kruskal-Wallis and Wilcoxon tests (p<0.05).ResultsNo statistically significant differences were found between the two irrigants used. Group 4 removed more debris than the other groups (p<0.05). Groups 1, 2, and 3 removed more debris than group 5 (p<0.05). A statistically significant difference (p<0.05) was found for the time of activation in all groups and at all canal levels, except between 40 and 60 seconds in group 4 at coronal and middle third level (p>0.05).ConclusionsNo significant differences were found between 5% sodium hypochlorite and 17% EDTA. When the time of activation rises, the dentin debris removal increases in all groups. Both sonic and ultrasonic activation demonstrate high capacity for dentin debris removal.
The aim of the present study was to compare the cyclic fatigue resistances of HyFlex EDM (HEDM), WaveOne Gold (WOG), Reciproc Blue (RB), and 2Shape (TS) NiTi systems having different metallurgic properties. HEDM, WOG, RB, and TS instruments were rotated in artificial canals which were made of stainless steel with an inner diameter of 1.5 mm, 45°, and 90° angles of curvatures and a radius of curvature of 5 mm until fracture occurred, and the time to fracture (TTF) was recorded in seconds. Also, number of cycles to fracture was calculated (NCF). Data were statistically analyzed using Kruskal-Wallis and t test. The statistical significance level was set at P < 0.05. When comparing the TTF of all the instruments tested in the artificial canal with 45° curvature, RB had statistically the highest cyclic fatigue resistance followed by HEDM and TS (P < 0.05), while the WOG showed the lowest cyclic fatigue resistance (P < 0.05). In artificial canal with 90° curvature, RB showed a significantly higher cyclic fatigue resistance than the other tested files (P < 0.05), while there was no significant difference among the TS, WOG and HEDM groups (P > 0.05). When the NCF values were taken into consideration, HEDM reported a significantly higher cyclic fatigue resistance than TS in both canal curvatures analyzed (P < 0.05). Within the limitations of the present study, RB NiTi files showed statistically higher cyclic fatigue resistance in artificial canals with 45° and 90° than the other NiTi files tested.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.