We established that converting to age-equivalent thresholds and application of dB* principle advantageously allows comparison of data sets across age and test size at different locations of the visual field. By identifying the Ac across the visual field, it is now possible to systematically determine threshold changes across the 30-2 locations in ocular disease and further characterize the importance of testing within complete spatial summation in standard automated perimetry.
PurposeTo characterize macular ganglion cell layer (GCL) changes with age and provide a framework to assess changes in ocular disease. This study used data clustering to analyze macular GCL patterns from optical coherence tomography (OCT) in a large cohort of subjects without ocular disease.MethodsSingle eyes of 201 patients evaluated at the Centre for Eye Health (Sydney, Australia) were retrospectively enrolled (age range, 20–85); 8 × 8 grid locations obtained from Spectralis OCT macular scans were analyzed with unsupervised classification into statistically separable classes sharing common GCL thickness and change with age. The resulting classes and gridwise data were fitted with linear and segmented linear regression curves. Additionally, normalized data were analyzed to determine regression as a percentage. Accuracy of each model was examined through comparison of predicted 50-year-old equivalent macular GCL thickness for the entire cohort to a true 50-year-old reference cohort.ResultsPattern recognition clustered GCL thickness across the macula into five to eight spatially concentric classes. F-test demonstrated segmented linear regression to be the most appropriate model for macular GCL change. The pattern recognition–derived and normalized model revealed less difference between the predicted macular GCL thickness and the reference cohort (average ± SD 0.19 ± 0.92 and −0.30 ± 0.61 μm) than a gridwise model (average ± SD 0.62 ± 1.43 μm).ConclusionsPattern recognition successfully identified statistically separable macular areas that undergo a segmented linear reduction with age. This regression model better predicted macular GCL thickness. The various unique spatial patterns revealed by pattern recognition combined with core GCL thickness data provide a framework to analyze GCL loss in ocular disease.
PurposeTo determine the locus of test locations that exhibit statistically similar age-related decline in sensitivity to light increments and age-corrected contrast sensitivity isocontours (CSIs) across the central visual field (VF). We compared these CSIs with test point clusters used by the Glaucoma Hemifield Test (GHT).MethodsSixty healthy observers underwent testing on the Humphrey Field Analyzer 30-2 test grid using Goldmann (G) stimulus sizes I-V. Age-correction factors for GI-V were determined using linear regression analysis. Pattern recognition analysis was used to cluster test locations across the VF exhibiting equal age-related sensitivity decline (age-related CSIs), and points of equal age-corrected sensitivity (age-corrected CSIs) for GI-V.ResultsThere was a small but significant test size–dependent sensitivity decline with age, with smaller stimuli declining more rapidly. Age-related decline in sensitivity was more rapid in the periphery. A greater number of unique age-related CSIs was revealed when using smaller stimuli, particularly in the mid-periphery. Cluster analysis of age-corrected sensitivity thresholds revealed unique CSIs for GI-V, with smaller stimuli having a greater number of unique clusters. Zones examined by the GHT consisted of test locations that did not necessarily belong to the same CSI, particularly in the periphery.ConclusionsCluster analysis reveals statistically significant groups of test locations within the 30-2 test grid exhibiting the same age-related decline. CSIs facilitate pooling of sensitivities to reduce the variability of individual test locations. These CSIs could guide future structure-function and alternate hemifield asymmetry analyses by comparing matched areas of similar sensitivity signatures.
When compared to the current Goldmann III paradigm, the use of alternate sized targets within the 30-2 testing protocol revealed a greater loss in patients with optic nerve disease for both event analysis and global indices (MD and PSD). We therefore provide evidence in a clinical setting that target size is important in visual field testing.
PurposeRecent studies propose that the use of target stimuli within or close to complete spatial summation reveal larger threshold elevation in ocular disease. The Humphrey Visual Field Analyzer (HFA) is used to assess visual function yet the spatial summation characteristics are unexplored for the central macular region. We therefore wanted to establish the relationship between contrast sensitivity and stimulus size (spatial summation) within the central 20° visual field using the high sampling density of the 10–2 test grid.MethodsThresholds were measured for one eye from 37 normal subjects using the HFA 10–2 test grid with all five Goldmann (G) targets (GI to GV). Subject data were converted to 50-year-old equivalent using published and calculated location-specific decade correction factors. Spatial summation curves were fitted for all data at all locations. The size of Ricco’s critical area (Ac) within which complete spatial summation operates (k = 1), and the slope of partial summation (k < 1: to characterize partial summation), was established.ResultsThe 50-year-old age normative data were determined for all Goldmann stimulus sizes for the 10–2 HFA test grid and showed a marked change in contrast sensitivity for small test stimuli (e.g. GI) and little change in larger test stimuli (e.g. GV). Both the Ac and k values did not vary with age allowing for the application of the age correction factors. Ac and k values increased with eccentricity with GI remaining within complete spatial summation and GII was close or within complete spatial summation. GIII or larger test sizes were always outside complete spatial summation operating within various levels of partial summation.ConclusionsThe developed normative data now allows comparisons of data sets with high sampling density using the 10–2 grid irrespective of subject age. Test size is important when assessing ocular disease yet only GI or GII stimuli operate close to or within complete spatial summation in the macula. Current visual field testing protocols employ GIII which is always outside complete spatial summation and operates under various values of partial summation: GIII may not be the most suitable test size to assess ocular disease affecting the macula.
PurposeGoldmann size V (GV) test stimuli are less variable with a greater dynamic range and have been proposed for measuring contrast sensitivity instead of size III (GIII). Since GIII and GV operate within partial summation, we hypothesise that actual GV (aGV) thresholds could predict GIII (pGIII) thresholds, facilitating comparisons between actual GIII (aGIII) thresholds with pGIII thresholds derived from smaller GV variances. We test the suitability of GV for detecting visual field (VF) loss in patients with early glaucoma, and examine eccentricity‐dependent effects of number and depth of defects. We also hypothesise that stimuli operating within complete spatial summation (‘spatially equated stimuli’) would detect more and deeper defects.MethodsSixty normal subjects and 20 glaucoma patients underwent VF testing on the Humphrey Field Analyzer using GI‐V sized stimuli on the 30‐2 test grid in full threshold mode. Point‐wise partial summation slope values were generated from GI‐V thresholds, and we subsequently derived pGIII thresholds using aGV. Difference plots between actual GIII (aGIII) and pGIII thresholds were used to compare the amount of discordance. In glaucoma patients, the number of ‘events’ (points below the 95% lower limit of normal), defect depth and global indices were compared between stimuli.Results90.5% of pGIII and aGIII points were within ±3 dB of each other in normal subjects. In the glaucoma cohort, there was less concordance (63.2% within ±3 dB), decreasing with increasing eccentricity. GIII found more defects compared to GV‐derived thresholds, but only at outermost test locations. Greater defect depth was found using aGIII compared to aGV and pGIII, which increased with eccentricity. Global indices revealed more severe loss when using GIII compared to GV. Spatially equated stimuli detected the greatest number of ‘events’ and largest defect depth.ConclusionsWhilst GV may be used to reliably predict GIII values in normal subjects, there was less concordance in glaucoma patients. Similarities in ‘event’ detection and defect depth in the central VF were consistent with the fact that GIII and GV operate within partial summation in this region. Eccentricity‐dependent effects in ‘events’ and defect depth were congruent with changes in spatial summation across the VF and the increase in critical area with disease. The spatially equated test stimuli showed the greatest number of defective locations and larger sensitivity loss.
In the present study, we measured the extent of spatial summation in the detection of image contrast within the central 40° visual field. Contrast detection thresholds (in 28 observers) were measured for a spot of light of 10 different sizes [area: 0.03-1.92(°)(2)] at different retinal meridians (0°, 45°, 90°, 135°, 180°, 225°, 270°, and 315°) and eccentricities (0°, 5°, 10°, 15°, and 20°). Contrast detection thresholds were significantly affected by the size of the stimulus with sensitivity improving with stimulus size consistent with Ricco's law. Summation curves were similar across different spatial meridians, but the extent of spatial summation increased with retinal eccentricity consistent with previous reports. The size of the stimulus was also shown to affect contrast detection thresholds in the periphery. In particular, contrast detection thresholds decreased more rapidly with increasing eccentricity for a smaller target than a larger one. This difference in performance is accounted for by the accompanying change in Ac with eccentricity. In Experiment 2, we show that spatial uncertainty affected contrast detection, particularly at eccentric locations greater than 5°, such that cueing the location of the stimulus improved contrast thresholds. Spatial uncertainty improved overall performance but did not affect the estimates of the critical areas of summation. The results of the present study indicate that, due to spatial summation, detection performance is highly dependent on the size of the stimulus, its eccentric location, and spatial uncertainty. Future perimetric methodologies must consider these factors to improve detection sensitivity.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.