Analog hardware architecture of a memristor bridge synapse-based multilayer neural network and its learning scheme is proposed. The use of memristor bridge synapse in the proposed architecture solves one of the major problems, regarding nonvolatile weight storage in analog neural network implementations. To compensate for the spatial nonuniformity and nonideal response of the memristor bridge synapse, a modified chip-in-the-loop learning scheme suitable for the proposed neural network architecture is also proposed. In the proposed method, the initial learning is conducted in software, and the behavior of the software-trained network is learned by the hardware network by learning each of the single-layered neurons of the network independently. The forward calculation of the single-layered neuron learning is implemented on circuit hardware, and followed by a weight updating phase assisted by a host computer. Unlike conventional chip-in-the-loop learning, the need for the readout of synaptic weights for calculating weight updates in each epoch is eliminated by virtue of the memristor bridge synapse and the proposed learning scheme. The hardware architecture along with the successful implementation of proposed learning on a three-bit parity network, and on a car detection network is also presented.
Objectives To evaluate the diagnostic performance of a deep convolutional neural network (DCNN)-based computer-assisted diagnosis (CAD) system in the detection of osteoporosis on panoramic radiographs, through a comparison with diagnoses made by oral and maxillofacial radiologists. Methods: Oral and maxillofacial radiologists with >10 years of experience reviewed the panoramic radiographs of 1268 females {mean [± standard deviation (SD)] age: 52.5 ± 22.3 years} and made a diagnosis of osteoporosis when cortical erosion of the mandibular inferior cortex was observed. Among the females, 635 had no osteoporosis [mean (± SD) age: 32.8 ± SD 12.1 years] and 633 had osteoporosis (72.2 ± 8.5 years). All panoramic radiographs were analysed using three CAD systems, single-column DCNN (SC-DCNN), single-column with data augmentation DCNN (SC-DCNN Augment) and multicolumn DCNN (MC-DCNN). Among the radiographs, 200 panoramic radiographs [mean (± SD) patient age: 63.9 ± 10.7 years] were used for testing the performance of the DCNN in detecting osteoporosis in this study. The diagnostic performance of the DCNN-based CAD system was assessed by receiver operating characteristic (ROC) analysis. Results: The area under the curve (AUC) values obtained using SC-DCNN, SC-DCNN (Augment) and MC-DCNN were 0.9763, 0.9991 and 0.9987, respectively. Conclusions: The DCNN-based CAD system showed high agreement with experienced oral and maxillofacial radiologists in detecting osteoporosis. A DCNN-based CAD system could provide information to dentists for the early detection of osteoporosis, and asymptomatic patients with osteoporosis can then be referred to the appropriate medical professionals.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.