Previous studies have indicated that macrophage phenotype diversity is involved in the progression of renal fibrosis. However, the factors facilitating M1 or M2 phenotypes and the function of these polarized macrophages in kidney injury and fibrosis remain largely unknown. In the present study, we found that macrophages accumulated in the kidney interstitium exhibited mainly as the M1 phenotype at the early stage of unilateral ureter obstruction (UUO). High-mobility group box 1 (HMGB1) protein expressed and released from tubular epithelial cells and interstitial macrophages was essential for the M1 macrophage transition. HMGB1 significantly induced the expression of the M1 marker inducible nitric oxide synthase while decreasing the M2 marker IL-10 in macrophages. Moreover, a glycyrrhizic acid derivative, a blocker of HMGB1 release, reduced UUO-mediated kidney injury and ameliorated UUO-induced renal fibrosis. Interestingly and importantly, UUO caused a low pH value in the urine accumulated in the obstructed ureter, and the acidified urine induced HMGB1 release from tubular epithelial cells and macrophages in vitro. Our data demonstrate that HMGB1 is an essential contributor in facilitating M1 polarization at the early stage of UUO. Inhibition of HMGB1 release may alter macrophage phenotype and contribute to the protection of kidney tissue from injury and fibrosis.
A simple, precise, rapid and accurate, binary-phase high performance liquid chromatographic method has been developed for the determination of oleanolic acid and ursolic acid contents in the Ziziphora clinopodioides Lam. with short run time. Chromatographic separation is achieved by using HPLC system consisting of a Shimadzu LC-6AD and Kromasil C18 column (150 × 4.6 mm, 10 μm, with pre-column), the mobile phase consists of methanol and 0.03 M phosphate buffer (pH = 3, 90:10). Detection wavelength is 214 nm. The speed of flow is 0.5 ml/min. The specimen handing quantity is 10 μl. The oleanolic acid's linearity range is 0.4 ~ 1.2 mg/ml (r = 0.9996). The ursolic acid's linearity range is 0.6 ~ 1.8 mg/ml (r = 0.9996), and the linear relationship is accurate. The average recovery (n = 6) of oleanolic acid is 99.5% (RSD = 1.19%) and ursolic acid is 102.3% (RSD = 1.25%). The content of oleanolic acid and ursolic acid in Ziziphora clinopodioides are 0.76 mg/g and 1.176 mg/g, respectively. The developed HPLC method can therefore be applied to both in vitro studies of oleanolic acid and ursolic acid formulations as well as drug estimation in biological samples.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.