In this article, using the non‐solvent induced phase separation process, a new microporous membrane with the semi‐interpenetrating polymer network (semi‐IPN) structure was produced. For this membrane, polydimethylsiloxane (PDMS) polymer is crosslinking and poly(vinylidene fluoride) (PVDF) polymer is linear, by changing the mass ratio of PDMS/PVDF, the structure and the performance of the prepared membranes were studied. The membranes were also investigated by attenuated total reflection‐Fourier transform infrared (ATR‐FTIR), scanning electron microscopy–energy‐dispersive X‐ray spectroscopy, X‐ray diffraction, thermogravimetric analysis, and water contact angle, etc. ATR‐FTIR spectroscopy confirmed the formation of semi‐IPN; compared with the PDMS/PVDF polymer without semi‐IPNs structure, the viscosity of the semi‐IPNs structured casting solution increased, membrane mechanical property increased but its hydrophobicity decreased. Using the resulting membranes for the vacuum membrane distillation desalt of the NaCl solution (30 g/L), 99.9% salt rejection and reasonable flux were obtained. © 2017 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 2018, 135, 45792.
Novel polyvinylidene fluoride (PVDF) ultrafiltration (UF) membranes were facilely fabricated using polyvinyl alcohol (PVA) aqueous solution as the coagulation bath through phase inversion method. In the process, PVA was introduced into the pore surfaces of the PVDF membranes via the interdiffusion of the non‐solvent water and the solvent. The effects of PVA content in the coagulation bath on membrane properties were systematically discussed. The results indicated that the increase of PVA content in coagulation bath resulted in the formations of the more sponge‐like structures and the higher surface hydrophilicity. Smaller pore size led to lower water flux and higher bovine serum albumin rejection. Fouling resistance measurement indicated that the membranes made in PVA/water coagulation bath had higher flux recovery ratio (92.1%) than the membrane made in a pure water bath (71.0%). Furthermore, mechanical property test revealed that the resulting membranes had high tensile strength and Young's modulus. In this work, we found that the morphology and the property of the novel PVDF membranes could be determined by the PVA content in the coagulation bath. POLYM. ENG. SCI., 59:E384–E393, 2019. © 2018 Society of Plastics Engineers
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.