Spinal pain is a major clinical problem, however, its origins and underlying mechanisms remain unclear. Here we report that in mice, osteoclasts induce sensory innervation in the porous endplates which contributes to spinal hypersensitivity in mice. Sensory innervation of the porous areas of sclerotic endplates in mice was confirmed. Lumbar spine instability (LSI), or aging, induces spinal hypersensitivity in mice. In these conditions, we show that there are elevated levels of PGE2 which activate sensory nerves, leading to sodium influx through Na v 1.8 channels. We show that knockout of PGE2 receptor 4 in sensory nerves significantly reduces spinal hypersensitivity. Inhibition of osteoclast formation by knockout Rankl in the osteocytes significantly inhibits LSI-induced porosity of endplates, sensory innervation, and spinal hypersensitivity. Knockout of Netrin-1 in osteoclasts abrogates sensory innervation into porous endplates and spinal hypersensitivity. These findings suggest that osteoclast-initiated porosity of endplates and sensory innervation are potential therapeutic targets for spinal pain.
BACKGROUND AND PURPOSE
Differentiating benign from malignant peripheral nerve sheath tumors can be very challenging using conventional MR imaging. Our aim was to test the hypothesis that conventional and functional MR imaging can accurately diagnose malignancy in patients with indeterminate peripheral nerve sheath tumors.
MATERIALS AND METHODS
This institutional review board–approved, Health Insurance Portability and Accountability Act–compliant study retrospectively reviewed 61 consecutive patients with 80 indeterminate peripheral nerve sheath tumors. Of these, 31 histologically proved peripheral nerve sheath tumors imaged with conventional (unenhanced T1, fluid-sensitive, contrast-enhanced T1-weighted sequences) and functional MR imaging (DWI/apparent diffusion coefficient mapping, dynamic contrast-enhanced MR imaging) were included. Two observers independently assessed anatomic (size, morphology, signal) and functional (ADC values, early arterial enhancement by dynamic contrast-enhanced MR) features to determine interobserver agreement. The accuracy of MR imaging for differentiating malignant from benign was also determined by receiver operating characteristic analysis.
RESULTS
Of 31 peripheral nerve sheath tumors, there were 9 malignant (9%) and 22 benign ones (81%). With anatomic sequences, average tumor diameter (6.3 ± 1.8 versus 3.9 ± 2.3 mm, P = .009), ill-defined/infiltrative margins (77% versus 32%; P = .04), and the presence of peritumoral edema (66% versus 23%, P = .01) were different for malignant peripheral nerve sheath tumors and benign peripheral nerve sheath tumors. With functional sequences, minimum ADC (0.47 ± 0.32 × 10−3 mm2/s versus 1.08 ± 0.26 × 10−3 mm2/s; P [H11021] .0001) and the presence of early arterial enhancement (50% versus 11%; P = .03) were different for malignant peripheral nerve sheath tumors and benign peripheral nerve sheath tumors. The minimum ADC (area under receiver operating characteristic curve was 0.89; 95% confidence interval, 0.73– 0.97) and the average tumor diameter (area under the curve = 0.8; 95% CI, 0.66 – 0.94) were accurate in differentiating malignant peripheral nerve sheath tumors from benign peripheral nerve sheath tumors. With threshold values for minimum ADC ≤ 1.0 × 10−3 mm2/s and an average diameter of ≥4.2 cm, malignancy could be diagnosed with 100% sensitivity (95% CI, 66.4%–100%).
CONCLUSIONS
Average tumor diameter and minimum ADC values are potentially important parameters that may be used to distinguish malignant peripheral nerve sheath tumors from benign peripheral nerve sheath tumors.
• CBCT provided adequate image quality for diagnostic tasks in extremity imaging. • CBCT images were "excellent" for "bone" and "good/adequate" for "soft tissue" visualization tasks. • CBCT image quality was equivalent/superior to MDCT for bone visualization tasks.
We accept the hypothesis that prospective compressed sensing acceleration of SEMAC is feasible for high-quality metal artifact reduction MRI of cobalt-chromium knee arthroplasty implants in less than 5 minutes and yields better quality than high-BW TSE and similarly high quality than lengthier SEMAC pulse sequences.
While all selective and WTV measurements offer good to excellent interobserver agreement, the selective OB method of ADC measurement results in the closest values to WTV measurements and requires significantly less measurement time than that required for the WTV method.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.