The patients’ inhalation flow pattern is one of the significant determinants for clinical performance of inhalation therapy. However, the development of inhalation flow meters for various inhalation devices has been unable to keep up with the increasing number of newly launched inhalation devices. In the present study, we developed simple attachment orifices for the inhalation flow pattern monitoring system, which are suitable for all commercial inhalers, and investigated the efficacy of the system on the clinical inhalation instruction for patients co-prescribed dry powder inhaler (DPI) and soft mist inhaler (SMI). First, we constructed simple attachment orifices that were adjusted for 13 commercial inhalers, and examined the correlation between orifice and inhalation device. Second, the inhalation flow patterns (peak inspiratory flow rate, PIFR; inhalation duration time, DT) of patients prescribed a combination of DPI and SMI were monitored before and after inhalation instruction. The inhalation resistance of commercial inhalers are listed in the following order; Twincaps® > Handihaler® > Swinghaler® = Clickhaler® > Twisthaler® > Turbuhaler® > Jenuair® > Diskus® = Ellipta® > Diskhaler® > Breezhaler® > Respimat® = pMDI. The pressure drop via orifice was significantly correlated with that via the commercial inhaler. For the confirmation, all participants achieved the DPI criterion of PIFR. On the other hand, 4 participants (6 clinical visits) of 10 experimented participants could not achieve the essential criterion of DT (> 1.5 sec) for SMI, but all participants improved their duration time after inhalation instruction by pharmacists (P<0.05). In the present study, we successfully developed simple attachment orifice suitable for 13 commercial inhalation devices. These data suggested that our simple attachment orifices for the inhalation flow pattern monitoring system can detect patients with inadequate inhalation patterns via SMI.
Elderly patients are apt to assume that they "understand well", therefore, in order to recognize and close the perception gap between elderly patients and medical professionals, it is necessary to provide them with more aggressive (frequent) instructions on inhalation therapy.
Hyposalivation is a significant prediction factor of hoarseness induced by inhaled corticosteroids (ICS). The prediction accuracy was higher in patients administered fluticasone than in those administered another inhalation drug. Although the pharmaceutical efficacy of fluticasone is high, patients with hyposalivation should be prescribed other inhalation drugs.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.