A scan type magnetic camera was proposed to satisfy the following demands: to obtain high speed quantitative magnetic flux leakage (MFL) distribution with homogeneous lift-off by using 2-dimensionally arrayed high sensitivity magnetic sensors; to concentrate the MFL; and to ignore the residual magnetization and magnetic hysteresis by using a magnetic fluid lens. The magnetic field distribution (MFD) image obtained by using the scan type magnetic camera is inclined to the scanning direction (x-direction) because of the poles of the magnetizer. Also, the image shows a homogeneous trend relative to the x-direction, but there are small waves in the distribution in the sensor arraying direction (y-direction). The crack information in the MFD image can be extracted using image processing. The first and second derivatives of both x and y are used in this processing. These are "1st derivative of x, ∂B/∂x", "1st derivative of y, ∂B/∂y", "2nd derivative of x, ∂2B/∂x2", "2nd derivative of y, ∂2B/∂y2", and "2nd derivative of x and y, ∂2B/∂x∂y". The ∂B/∂x distribution shows the existence of the crack. Also, the crack volume can be evaluated quantitatively, regardless of the crack direction, by using ∂B/∂x and a cross type magnetic coil.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.