GA. Intrafascicular stimulation of monkey arm nerves evokes coordinated grasp and sensory responses.
The production of graceful skeletal movements requires coordinated activation of multiple muscles that produce torques around multiple joints. The work described herein is focused on one such movement, stance, that requires coordinated activation of extensor muscles acting around the hip, knee and ankle joints. The forces evoked in these muscles by external stimulation all have a complex dependence on muscle length and shortening velocities, and some of these muscles are bi-articular. In order to recreate sit-to-stand maneuvers in the anesthetized feline, we excited the hind limb musculature using intrafascicular multielectrode stimulation (IFMS) of the muscular branch of the sciatic nerve, the femoral nerve, and the main branch of the sciatic nerve. Stimulation was achieved with either acutely or chronically implanted Utah Slanted Electrode Arrays (USEAs) via subsets of electrodes 1) that activated motor units in the extensor muscles of the hip, knee, and ankle joints, 2) that were able to evoke large extension forces, and 3) that manifested minimal coactivation of the targeted motor units. Three hind limb force-generation strategies were investigated, including sequential activation of independent motor units to increase force, and interleaved or simultaneous IFMS of three sets of six or more USEA electrodes that excited the hip, knee, and ankle extensors. All force-generation strategies evoked stance, but the interleaved IFMS strategy also reduced muscle fatigue produced by repeated sit-to-stand maneuvers compared with fatigue produced by simultaneous activation of different motor neuron pools. These results demonstrate the use of interleaved IFMS as a means to recreate coordinated, fatigue-resistant multi-joint muscle forces in the unilateral hind limb. This muscle activation paradigm could provide a promising neuroprosthetic approach for the restoration of sit-to-stand transitions in individuals who are paralyzed by spinal cord injury, stroke, or disease.
We have developed a prototype implantable device for recording multiple independent channels of EMG and sending those signals wirelessly to an external receiver. This design records multichannel EMG signals for providing simultaneous multi-axis control of prosthetic limbs. This proof-of-concept study demonstrates benchtop performance of the bioamplifier in dry and soaked in saline configurations, as well as system performance in a short-term in vivo study in six dogs. The amplifier was shown to have an input-referred noise of 2.2 µV(RMS), a common mode rejection ratio greater than 55 dB, and neighboring channel isolation averaging 66 dB. The prototype devices were constructed of an amplifier ASIC along with discrete components for wireless function. These devices were coated in silicone and implanted for at least one week in each dog. EMG recorded from each animal as it walked down a hallway had very low noise and swing/stance phases of gait were clearly shown. This study demonstrates this device design can be used to amplify and transmit muscle signals.
The muscles of the hamstring group can produce different combinations of hip and knee torque. Thus, the ability to activate the different hamstring muscles selectively is of particular importance in eliciting functional movements such as stance and gait in a person with spinal cord injury. We investigated the ability of intrafascicular stimulation of the muscular branch of the sciatic nerve to recruit the feline hamstring muscles in a selective and graded fashion. A Utah Slanted Electrode Array, consisting of 100 penetrating microelectrodes, was implanted into the muscular branch of the sciatic nerve in six cats. Muscle twitches were evoked in the three compartments of biceps femoris (anterior, middle, and posterior), as well as semitendinosus and semimembranosus, using pulse-width modulated constant-voltage pulses. The resultant compound muscle action potentials were recorded using intramuscular fine-wire electrodes. 74% of the electrodes per implant were able to evoke a threshold response in these muscles, and these electrodes were evenly distributed among the instrumented muscles. Of the five muscles instrumented, on average 2.5 could be selectively activated to 90% of maximum EMG, and 3.5 could be selectively activated to 50% of maximum EMG. The muscles were recruited selectively with a mean stimulus dynamic range of 4.14 +/- 5.05 dB between threshold and either spillover to another muscle or a plateau in the response. This selective and graded activation afforded by intrafascicular stimulation of the muscular branch of the sciatic nerve suggests that it is a potentially useful stimulation paradigm for eliciting distinct forces in the hamstring muscle group in motor neuroprosthetic applications.
Over the past decade, research in the field of functional electrical stimulation (FES) has led to a new generation of high-electrode-count (HEC) devices that offer increasingly selective access to neural populations. Incorporation of these devices into research and clinical applications, however, has been hampered by the lack of hardware and software platforms capable of taking full advantage of them. In this paper, we present the first generation of a closed-loop FES platform built specifically for HEC neural interface devices. The platform was designed to support a wide range of stimulus-response mapping and feedback-based control routines. It includes a central control module, a 1100-channel stimulator, an array of biometric devices, and a 160-channel data recording module. To demonstrate the unique capabilities of this platform, two automated software routines for mapping stimulus-response properties of implanted HEC devices were implemented and tested. The first routine determines stimulation levels that produce perithreshold muscle activity, and the second generates recruitment curves (as measured by peak impulse response). Both routines were tested on 100-electrode Utah Slanted Electrode Arrays (USEAs) implanted in cat hindlimb nerves using joint torque or emg as muscle output metric. Mean time to map perithreshold stimulus level was 16.4 s for electrodes that evoked responses (n = 3200), and 3.6 s for electrodes that did not evoke responses (n = 1800). Mean time to locate recruitment curve asymptote for an electrode (n = 155) was 9.6 s , and each point in the recruitment curve required 0.87 s. These results demonstrate the utility of our FES platform by showing that it can be used to completely automate a typically time- and effort-intensive procedure associated with using HEC devices.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.