BackgroundThe use of magnetic resonance (MR) imaging as a part of preparation for radiotherapy is increasing. For delineation of the prostate several publications have shown decreased delineation variability using MR compared to computed tomography (CT). The purpose of the present work was to investigate the intra- and inter-physician delineation variability for prostate and seminal vesicles, and to investigate the influence of different MR sequence settings used clinically at the five centers participating in the study.MethodsMR series from five centers, each providing five patients, were used. Two physicians from each center delineated the prostate and the seminal vesicles on each of the 25 image sets. The variability between the delineations was analyzed with respect to overall, intra- and inter-physician variability, and dependence between variability and origin of the MR images, i.e. the MR sequence used to acquire the data.ResultsThe intra-physician variability in different directions was between 1.3 - 1.9 mm and 3 – 4 mm for the prostate and seminal vesicles respectively (1 std). The inter-physician variability for different directions were between 0.7 – 1.7 mm and approximately equal for the prostate and seminal vesicles. Large differences in variability were observed for individual patients, and also for individual imaging sequences used at the different centers. There was however no indication of decreased variability with higher field strength.ConclusionThe overall delineation variability is larger for the seminal vesicles compared to the prostate, due to a larger intra-physician variability. The imaging sequence appears to have a large influence on the variability, even for different variants of the T2-weighted spin-echo based sequences, which were used by all centers in the study.
These findings are consistent with expansion of cardia in healthy volunteers occurring by squamo columnar metaplasia of distal oesophagus and aggravated by central obesity. This metaplastic origin of expanded cardia may be relevant to the substantial proportion of cardia adenocarcinomas unattributable to H. pylori or transsphincteric acid reflux.
Objective: To investigate the necessity of performing MRI in the radiotherapy position when using MRI for prostatic radiotherapy. Methods: 20 prostate patients received a CT, diagnostic MRI and an MRI scan in the radiotherapy position. The quality of registration between CT and MRI was compared between the two MRI set-ups. The prostate and seminal vesicles were contoured using all scans and intensity modulated radiotherapy (IMRT) plans were generated. Changes in the target volume and IMRT plans were investigated. Two-tailed paired Student's ttests determined the statistical significance.Results: There was a decrease in the mean distance from the centre of the bony anatomy between CT and MRI (from 3.9 to 1.9 mm, p-value,0.0001) when the MRI scan was acquired in the radiotherapy position. Assuming that registering CT with an MRI scan in the radiotherapy position is the gold standard for delineating the prostate and seminal vesicles, using a planning target volume delineated on the CT with a diagnostic MRI scan viewed separately, resulted in a mean conformation number of 0.80 instead of the expected 0.98 (p,0.0001). Conclusion: By registering CT with an MRI scan in the radiotherapy position, there is a statistically significant improvement in the registration and IMRT quality. Advances in knowledge: To achieve an acceptable registration and IMRT quality in prostatic radiotherapy, neither CT with a separate diagnostic MRI nor CT registered to a diagnostic MRI will suffice. Instead, a CT registered with an MRI in the radiotherapy position should be used.
BackgroundThe purpose of this study was to demonstrate how magnetic resonance imaging (MRI) patient position protocols influence registration quality in patients with oropharyngeal cancer undergoing radical radiotherapy and the consequences for gross tumour volume (GTV) definition and radiotherapy planning.Methods and materialsTwenty-two oropharyngeal patients underwent a computed tomography (CT), a diagnostic MRI (MRID) and an MRI in the radiotherapy position within an immobilization mask (MRIRT). Clinicians delineated the GTV on the CT viewing the MRID separately (GTVC); on the CT registered to MRID (GTVD) and on the CT registered to MRIRT (GTVRT). Planning target volumes (PTVs) were denoted similarly. Registration quality was assessed by measuring disparity between structures in the three set-ups. Volumetric modulated arc therapy (VMAT) radiotherapy planning was performed for PTVC, PTVD and PTVRT. To determine the dose received by the reference PTVRT, we optimized for PTVC and PTVD while calculating the dose to PTVRT. Statistical significance was determined using the two-tailed Mann–Whitney or two-tailed paired student t-tests.ResultsA significant improvement in registration accuracy was found between CT and MRIRT versus the MRID measuring distances from the centre of structures (geometric mean error of 2.2 mm versus 6.6 mm). The mean GTVC (44.1 cm3) was significantly larger than GTVD (33.7 cm3, p value = 0.027) or GTVRT (30.5 cm3, p value = 0.014). When optimizing the VMAT plans for PTVC and investigating the mean dose to PTVRT neither the dose to 99% (58.8%) nor 95% of the PTV (84.7%) were found to meet the required clinical dose constraints of 90% and 95% respectively. Similarly, when optimizing for PTVD the mean dose to PTVRT did not meet clinical dose constraints for 99% (14.9%) nor 95% of the PTV (66.2%). Only by optimizing for PTVRT were all clinical dose constraints achieved.ConclusionsWhen oropharyngeal patients MRI scans are performed in the radiotherapy position there are significant improvements in CT-MR image registration, target definition and PTV dose coverage.
This study investigated the compatibility of a head and neck immobilization device with magnetic resonance imaging (MRI). The immobilization device is used to position a patient in the same way as when receiving a computed tomography (CT) scan for radiotherapy planning and radiation treatment. The advantage of using immobilization in MR is improved accuracy in CT/MR image registration enabling greater confidence in the delineation of structures. The main practical difficulty in using an immobilization device in MRI is that physical constraints make their use incompatible with head imaging coils. Within this paper we describe a method for MR imaging of the brain which allows the use of head and neck immobilization devices. By a series of image quality tests we obtained the same or better image quality as a multi-channel head coil.
Aims/hypothesis South Asians have a two- to fivefold higher risk of developing type 2 diabetes than those of white European descent. Greater central adiposity and storage of fat in deeper or ectopic depots are potential contributing mechanisms. We collated existing and new data on the amount of subcutaneous (SAT), visceral (VAT) and liver fat in adults of South Asian and white European descent to provide a robust assessment of potential ethnic differences in these factors. Methods We performed a systematic review of the Embase and PubMed databases from inception to August 2021. Unpublished imaging data were also included. The weighted standardised mean difference (SMD) for each adiposity measure was estimated using random-effects models. The quality of the studies was assessed using the ROBINS-E tool for risk of bias and overall certainty of the evidence was assessed using the GRADE approach. The study was pre-registered with the OSF Registries (https://osf.io/w5bf9). Results We summarised imaging data on SAT, VAT and liver fat from eight published and three previously unpublished datasets, including a total of 1156 South Asian and 2891 white European men, and 697 South Asian and 2271 white European women. Despite South Asian men having a mean BMI approximately 0.5–0.7 kg/m2 lower than white European men (depending on the comparison), nine studies showed 0.34 SMD (95% CI 0.12, 0.55; I2=83%) more SAT and seven studies showed 0.56 SMD (95% CI 0.14, 0.98; I2=93%) more liver fat, but nine studies had similar VAT (−0.03 SMD; 95% CI −0.24, 0.19; I2=85%) compared with their white European counterparts. South Asian women had an approximately 0.9 kg/m2 lower BMI but 0.31 SMD (95% CI 0.14, 0.48; I2=53%) more liver fat than their white European counterparts in five studies. Subcutaneous fat levels (0.03 SMD; 95% CI −0.17, 0.23; I2=72%) and VAT levels (0.04 SMD; 95% CI −0.16, 0.24; I2=71%) did not differ significantly between ethnic groups in eight studies of women. Conclusions/interpretation South Asian men and women appear to store more ectopic fat in the liver compared with their white European counterparts with similar BMI levels. Given the emerging understanding of the importance of liver fat in diabetes pathogenesis, these findings help explain the greater diabetes risks in South Asians. Funding There was no primary direct funding for undertaking the systematic review and meta-analysis. Graphical abstract
Background: Planning radiosurgery to multiple intracranial metastases is complex and shows large variability in dosimetric quality among planners and treatment planning systems (TPS). This project aimed to determine whether autoplanning using the Muliple Brain Mets (AutoMBM) software can improve plan quality and reduce inter-planner variability by crowdsourcing results from prior international planning study. Methods: Twenty-four institutions autoplanned with AutoMBM on a five metastases case from a prior international planning competition from which population statistics (means and variances) of 23 dosimetric metrics and resulting composite plan score (maximum score = 150) of other TPS (Eclipse, Monaco, RayStation, iPlan, GammaPlan, MultiPlan) were crowdsourced. Plan results of AutoMBM and each of the other TPS were compared using two sample t-tests for means and Levene's tests for variances. Plan quality of AutoMBM was correlated with the planner' experience and compared between academic and non-academic centers. Results: AutoMBM produced plans with comparable composite plan score to GammaPlan, MultiPlan, Eclipse and iPlan (127.6 vs. 131.7 vs. 127.3 vs. 127.3 and 126.7; all p > 0.05) and superior to Monaco and RayStation (118.3 and 108.6; both p < 0.05). Inter-planner variability of overall plan quality was lowest for AutoMBM among all TPS (all p < 0.05). AutoMBM's plan quality did not differ between academic and non-academic centers and uncorrelated with planning experience (all p > 0.05).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.