The United Kingdom Collaborative Trial of Ovarian Cancer Screening (UKCTOCS) recently reported a reduction in the average overall mortality among ovarian cancer patients screened with an annual sequential, multimodal strategy that tracked biomarker CA125 over time, where increasing serum CA125 levels prompted ultrasound. However, multiple cases were documented wherein serum CA125 levels were rising, but ultrasound screens were normal, thus delaying surgical intervention. A significant factor which could contribute to false negatives is that many aggressive ovarian cancers are believed to arise from epithelial cells on the fimbriae of the fallopian tubes, which are not readily imaged. Moreover, because only a fraction of metastatic tumors may reach a sonographically-detectable size before they metastasize, annual screening with ultrasound may fail to detect a large fraction of early-stage ovarian cancers. The ability to detect ovarian carcinomas before they metastasize is critical and future efforts towards improving screening should focus on identifying unique features specific to aggressive, early-stage tumors, as well as improving imaging sensitivity to allow for detection of tubal lesions. Implementation of a three-stage multimodal screening strategy in which a third modality is employed in cases where the first-line blood-based assay is positive and the second-line ultrasound exam is negative may also prove fruitful in detecting early-stage cases missed by ultrasound.
This is a PDF file of an article that has undergone enhancements after acceptance, such as the addition of a cover page and metadata, and formatting for readability, but it is not yet the definitive version of record. This version will undergo additional copyediting, typesetting and review before it is published in its final form, but we are providing this version to give early visibility of the article. Please note that, during the production process, errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain.
Computed tomography (CT) technology has rapidly evolved since its introduction in the 1970s. It is a highly important diagnostic tool for clinicians as demonstrated by the significant increase in utilization over several decades. However, much of the effort to develop and advance CT applications has been focused on improving visual sensitivity and reducing radiation dose. In comparison to these areas, improvements in quantitative CT have lagged behind. While this could be a consequence of the technological limitations of conventional CT, advanced dual-energy CT (DECT) and photoncounting detector CT (PCD-CT) offer new opportunities for quantitation. Routine use of DECT is becoming more widely available and PCD-CT is rapidly developing. This review covers efforts to address an unmet need for improved quantitative imaging to better characterize disease, identify biomarkers, and evaluate therapeutic response, with an emphasis on multi-energy CT applications. The review will primarily discuss applications that have utilized quantitative metrics using both conventional and DECT, such as bone mineral density measurement, evaluation of renal lesions, and diagnosis of fatty liver disease. Other topics that will be discussed include efforts to improve quantitative CT volumetry and radiomics. Finally, we will address the use of quantitative CT to enhance image-guided techniques for surgery, radiotherapy and interventions and provide unique opportunities for development of new contrast agents.
(1) Background: The Exradin W2 is a commercially available scintillator detector designed for reference and relative dosimetry in small fields. In this work, we investigated the performance of the W2 scintillator in a 10 MV flattening-filter-free photon beam and compared it to the performance of ion chambers designed for small field measurements. (2) Methods: We measured beam profiles and percent depth dose curves with each detector and investigated the linearity of each system based on dose per pulse (DPP) and pulse repetition frequency. (3) Results: We found excellent agreement between the W2 scintillator and the ion chambers for beam profiles and percent depth dose curves. Our results also showed that the two-voltage method of calculating the ion recombination correction factor was sufficient to correct for the ion recombination effect of ion chambers, even at the highest DPP. (4) Conclusions: These findings show that the W2 scintillator shows excellent agreement with ion chambers in high DPP conditions.
Superparamagnetic relaxometry (SPMR) exploits the unique magnetic properties of targeted superparamagnetic iron oxide nanoparticles (SPIOs) to detect small numbers of cancer cells. Reconstruction of the spatial distribution of cancer-bound nanoparticles requires solving an ill-posed inverse problem. The current method, multiple source analysis (MSA), uses a least-squares fit to determine the strength and location of a pre-determined number of magnetic dipoles. In this proof-of-concept study, we propose the application of a sparsity averaged reweighting algorithm (SARA) for volumetric reconstruction of immobilized nanoparticle distributions. We first calibrate the parameters that define the location of the sensors in the forward model of measurement physics. Using this optimized model, we evaluated the performance of the algorithms on various configurations of single and multiple point-source phantoms. We investigated the effect of the data fidelity parameter, voxel size, and iterative reweighting on the reconstruction produced by SARA. We found that the calibrated physics model can predict the detected field values within 5% of the measured data. When only a single source was present, both algorithms were able to detect as little as 0.5 µg of immobilized particles. However, when two sources were measured simultaneously, MSA failed to detect sources containing as much as 10 µg of particles, while SARA detected all of the sources containing at least 5 µg of particles. We show that a suitable data fidelity parameter can be selected objectively, and the total magnitude and location of a point source reconstructed by SARA is not sensitive to voxel size. Detection and localization of multiple small clusters of nanoparticles is a crucial step in SPMR-based diagnostic applications. Our algorithm overcomes the need to know the number of dipoles before reconstruction and improves the sensitivity of the reconstruction when multiple sources are present.
The clinical presentation of amyotrophic lateral sclerosis (ALS), a fatal neurodegenerative disease, varies widely across patients, making it challenging to determine if potential therapeutics slow progression. We sought to determine whether there were common patterns of disease progression that could aid in the design and analysis of clinical trials. We developed an approach based on a mixture of Gaussian processes to identify clusters of patients sharing similar disease progression patterns, modeling their average trajectories and the variability in each cluster. We show that ALS progression is frequently nonlinear, with periods of stable disease preceded or followed by rapid decline. We also show that our approach can be extended to Alzheimer’s and Parkinson’s diseases. Our results advance the characterization of disease progression of ALS and provide a flexible modeling approach that can be applied to other progressive diseases.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.