Purpose
The prime factor in determining the success of reimplantation of an avulsed tooth is the maintenance of the viability of periodontal ligament fibroblast cells (PDFC). This study aims to evaluate and compare Mc Carey Kaufman media (MK), Cornisol, Dulbecco’s Modified Eagles Medium (DMEM), Hanks Balanced Salt Solution (HBSS) and distilled water in preserving the viability of the PDFC using the Cell Counting Kit-8 assay (CCK-8).
Methods
Cryopreserved PDFC were suspended in DMEM and incubated in CO
2
incubator at 370C with 95% humidity and 5% CO
2
for attachment. Once cells attained 80% confluence, they were trypsinised and passed into T-25 culture flasks to expand the culture population. Cells from passage 5 were pooled for experimentation. Trypan blue exclusion test was performed before each experiment to measure cell viability and batches showing more than 95% viability were used in the experiment. The viable PDFC with 1×105 were seeded in 96 well plates and incubated in CO
2
incubator at 370C, 95% humidity and 5% CO
2
for 24 hours to allow cell attachment. A 100µL of the experimental media were added in the wells and the cells were exposed for 1, 24 and 48 hours respectively. The viability was determined using the CCK-8. Experiment was performed in triplicates and data was subjected to statistical analysis.
Results
Statistical analysis was performed using repeated measure ANOVA, ANOVA, and post-hoc Bonferroni test with the significance level p<0.05. The values are as follows: MK (1.3146 ±0.0588, 1.9012±0.0511, 2.0723±0.1211) > Cornisol (1.2399±0.0548, 1.9596±0.0652, 1.9592±0.1361) >DMEM (1.1914±0.0691, 1.8479±0.0116, 2.0718±0.0795) > HBSS (0.3665±0.0814, 0.0184±0.0010, 0.0248±0.0042) >distilled water (0.0122±0.0033, 0.0225±0.0085, 0.0104±0.0008) at 1 hour, 24 hours and 48 hours respectively. MK >Cornisol>DMEM>HBSS>distilled water.
Conclusion
It can be concluded that the corneal preservation solutions showed promising results in preserving periodontal ligament cell viability for extended time periods.
To compare the color stability of Cention N, Fuji IX GP Extra, and Fuji IX GP after thermocycling. Material and Methods: Ten discs of each material of dimension 10 x 1 mm were prepared using a split mold. The preparations of the specimens were done according to the powder/liquid ratio as recommended by the manufacturers [4.6:1, 3.4:1 and 3.6:1 for the groups I, II, and III, respectively]. After setting, the samples were retrieved, and the thickness of each specimen was measured using a micrometer at five different locations. The specimens with variations in thickness, porosity or cracks were discarded and thus not included in the study. The selected specimens were stored in distilled water for 24 hours prior to testing. The prepared specimens were thermocycled at 5°C and 55°C, with a dwell time of 15 seconds for 250 or 500 cycles. Subsequently, the color parameters of the discs were measured using a spectrophotometer. The data were analyzed using two way ANOVA test, and a p-value <0.001 was considered. Results: Thermocycling resulted in changes in the color of both Glass Ionomer cement and Cention N (p<0.001). Among the materials tested, Cention N showed superior color stability. Conclusion: Cention N exhibited better color stability compared to Glass ionomer cements.
To compare the fluoride release from Conventional Glass Ionomer Cement (GIC), Resin Modified GIC (RMGIC), and Cention N Alkasite Material. Material and Methods: Forty-five disc-shaped specimens of three different restorative materials (Conventional GIC, RMGIC, and Alkasite material) were made and divided into 3 groups (n=15). Fluoride release was evaluated at the end of Day 1, 7, 14, and Day 28 using fluoride ion-selective electrode. Intergroup and Intra-group analysis was done using One-way ANOVA with a Post-hoc test. A p-value of <0.05 was considered statistically significant. Results: Cention showed more fluoride release (in parts per million) than GIC and RMGIC at increased time duration. However, at the end of day 1, there was lesser fluoride release with Cention, as compared with the other groups. Conclusion: The new Alkasite restorative material showed promising results in terms of fluoride release and is better than GIC and RMGIC at increased time duration.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.