One of the most common assessments for the mobility of older people is the Timed Up and Go test (TUG). Due to its sensitivity regarding the indication of Parkinson’s disease (PD) or increased fall risk in elderly people, this assessment test becomes increasingly relevant, should be automated and should become applicable for unsupervised self-assessments to enable regular examinations of the functional status. With Inertial Measurement Units (IMU) being well suited for automated analyses, we evaluate an IMU-based analysis-system, which automatically detects the TUG execution via machine learning and calculates the test duration. as well as the duration of its single components. The complete TUG was classified with an accuracy of 96% via a rule-based model in a study with 157 participants aged over 70 years. A comparison between the TUG durations determined by IMU and criterion standard measurements (stopwatch and automated/ambient TUG (aTUG) system) showed significant correlations of 0.97 and 0.99, respectively. The classification of the instrumented TUG (iTUG)-components achieved accuracies over 96%, as well. Additionally, the system’s suitability for self-assessments was investigated within a semi-unsupervised situation where a similar movement sequence to the TUG was executed. This preliminary analysis confirmed that the self-selected speed correlates moderately with the speed in the test situation, but differed significantly from each other.
An early detection of functional decline with age is important to start interventions at an early state and to prolong the functional fitness. In order to assure such an early detection, functional assessments must be conducted on a frequent and regular basis. Since the five time chair rise test (5CRT) is a well-established test in the geriatric field, this test should be supported by technology. We introduce an approach that automatically detects the execution of the chair rise test via an inertial sensor integrated into a belt. The system’s suitability was evaluated via 20 subjects aged 72–89 years (78.2 ± 4.6 years) and was measured by a stopwatch, the inertial measurement unit (IMU), a Kinect® camera and a force plate. A Multilayer Perceptrons-based classifier detects transitions in the IMU data with an F1-Score of around 94.8%. Valid executions of the 5CRT are detected based on the correct occurrence of sequential movements via a rule-based model. The results of the automatically calculated test durations are in good agreement with the stopwatch measurements (correlation coefficient r = 0.93 (p < 0.001)). The analysis of the duration of single test cycles indicates a beginning fatigue at the end of the test. The comparison of the movement pattern within one person shows similar movement patterns, which differ only slightly in form and duration, whereby different subjects indicate variations regarding their performance strategies.
Comprehensive and repetitive assessments are needed to detect physical changes in an older population to prevent functional decline at the earliest possible stage and to initiate preventive interventions. Established instruments like the Timed “Up & Go” (TUG) Test and the Sit-to-Stand Test (SST) require a trained person (e.g., physiotherapist) to assess physical performance. More often, these tests are only applied to a selected group of persons already functionally impaired and not to those who are at potential risk of functional decline. The article introduces the Unsupervised Screening System (USS) for unsupervised self-assessments by older adults and evaluates its validity for the TUG and SST. The USS included ambient and wearable movement sensors to measure the user’s test performance. Sensor datasets of the USS’s light barriers and Inertial Measurement Units (IMU) were analyzed for 91 users aged 73 to 89 years compared to conventional stopwatch measurement. A significant correlation coefficient of 0.89 for the TUG test and of 0.73 for the SST were confirmed among USS’s light barriers. Correspondingly, for the inertial data-based measures, a high and significant correlation of 0.78 for the TUG test and of 0.87 for SST were also found. The USS was a validated and reliable tool to assess TUG and SST.
Cardiopulmonary resuscitation (CPR) is alongside electrical defibrillation the most crucial countermeasure for sudden cardiac arrest, which affects thousands of individuals every year. In this paper, we present a novel approach including sinusoid models that use skeletal motion data from an RGB-D (Kinect) sensor and the Differential Evolution (DE) optimization algorithm to dynamically fit sinusoidal curves to derive frequency and depth parameters for cardiopulmonary resuscitation training. It is intended to be part of a robust and easy-to-use feedback system for CPR training, allowing its use for unsupervised training. The accuracy of this DE-based approach is evaluated in comparison with data of 28 participants recorded by a state-of-the-art training mannequin. We optimized the DE algorithm hyperparameters and showed that with these optimized parameters the frequency of the CPR is recognized with a median error of ±2.9 compressions per minute compared to the reference training mannequin.
Background It is important to identify the relevant parameters of physical performance to prevent early functional decline and to prolong independent living. The aim of this study is to describe the development of physical performance in a healthy community-dwelling older cohort aged 70+ years using comprehensive assessment over two years and to subsequently identify the most relevant predictive tests for physical decline to minimize assessment. Methods Physical performance was measured by comprehensive geriatric assessment. Predictors for the individual decline of physical performance by Principal Component and k-means Cluster Analysis were developed, and sensitivity and specificity determined accordingly. Results 251 subjects (Ø 75.4 years) participated in the study. Handgrip strength was low in 21.1%. The follow-up results of tests were divergent. Handgrip strength [− 16.95 (SD 11.55)] and the stair climb power test (power) [− 9.15 (SD 16.84)] yielded the highest percentage changes. Four most relevant tests (handgrip strength, stair climb power time, timed up & go and 4-m gait speed) were identified. A predictor based on baseline data was determined (sensitivity 82%, specificity 96%) to identify subjects characterized by a high degree of physical decline within two years. Discussion Although the cohort of older adults is heterogeneous, most of the individuals in the study exhibited high levels of physical performance; only a few subjects suffered a relevant decline within the 2-year follow-up. Four most relevant tests were identified to predict relevant decline of physical function. Conclusion In spite of ceiling effects of the geriatric assessment in high-performers, we assume that it is possible to predict an individual's risk of physical decline within 2 years with four tests of a comprehensive geriatric assessment.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.