Background Construct stiffness affects healing of bones fixed with locking plates. However, variable construct stiffness reported in the literature may be attributable to differing test configurations and direct comparisons may clarify these differences. Questions/purposes We therefore asked whether different distal femur locking plate systems and constructs will lead to different (1) axial and rotational stiffness and (2) fatigue under cyclic loading. Methods We investigated four plate systems for distal femur fixation (AxSOS, LCP, PERI-LOC, POLYAX) of differing designs and materials using bone substitutes in a distal femur fracture model (OTA/AO 33-A3). We created six constructs of each of the four plating systems. Stiffness under static and cyclic loading and fatigue under cyclic loading were measured.
Background:Femoral suspensory fixation for anterior cruciate ligament (ACL) reconstruction has evolved from fixed- to adjustable-loop devices. However, there are still controversies regarding undesired lengthening of adjustable-loop devices.Hypothesis:Adjustable-loop fixation will achieve similar elongation to that of fixed-loop devices, and intraoperative preconditioning will reduce initial elongation for adjustable-loop constructs.Study Design:Controlled laboratory study.Methods:Three adjustable-loop devices (GraftMax, TightRope, and Ultrabutton) and 2 fixed-loop devices (Endobutton and RetroButton) were used in an intraoperative surgical technique workflow according to an in vitro model with porcine bone and bovine tendons (8 specimens per device; N = 40 constructs tested). Each construct underwent 1000 cycles of position- and force-controlled dynamic loading, whereby a total elongation threshold of 3 mm was defined as clinical failure. Constructs were finally pulled to failure at 50 mm/min.Results:There were no statistically significant differences among the devices for total or dynamic elongation. Total elongation (mean ± SD) for adjustable-loop constructs was 4.13 ± 1.46 mm for GraftMax, 2.78 ± 0.85 mm for TightRope, and 2.76 ± 0.45 mm for Ultrabutton; for the fixed-loop devices, total elongation was 2.85 ± 0.74 mm for Endobutton and 2.85 ± 1.03 mm for RetroButton. The GraftMax had a significantly lower initial force (95.5 ± 58.0 N) after retensioning, with the highest initial elongation (0.99 ± 0.60 mm). The Ultrabutton showed the greatest force loss (–105.9 ± 13.5 N) during position control cycling, which was significantly different from the GraftMax (–22.3 ± 28.2 N), with the smallest force loss (P < .001). The TightRope construct had a significantly smaller initial elongation (–0.36 ± 0.22 mm) and the greatest pull-to-failure load (958 ± 40 N) as compared with all of the other devices.Conclusion:Adjustable- and fixed-loop configurations achieved statistically comparable fixation strength for total elongation. However, the GraftMax construct exceeded the total elongation threshold of clinical failure. The Ultrabutton produced the greatest loss of force during position control cycling, and the GraftMax button design prevented proper retensioning. The TightRope had a significant greater ultimate strength when compared with all other devices.Clinical Relevance:Biomechanical testing according to a surgical technique workflow suggests that adjustable-loop devices can be considered a safe alternative to fixed-loop devices in ACL reconstruction.
Background: The latest biomechanical studies on some form of internal bracing have shown improved stabilization for anterior cruciate ligament (ACL) repair, but gap formation and load-sharing function have not yet been reported. Hypothesis: Internal bracing of an adjustable ACL repair construct provides improved stabilization with reduced gap formation and higher residual loading on the ACL. Study Design: Controlled laboratory study. Methods: Internally braced ACL repair constructs with single– and double–cinch loop (CL) cortical buttons, a knotless suture anchor, and a single-CL cortical button with adjustable loop fixation (CLS-ALD) were tested (n = 20 each) in a porcine model at 4 different loads (n = 5 each) over 4000 cycles at 0.75 Hz (n = 80 total). The CLS-ALD technique allowed for additional preconditioning (10 cycles at 0.5 Hz). Test results of the isolated internal brace groups served as a baseline for comparison. Lastly, specimens were pulled to failure (50 mm/min) with a cut internal brace. Final loading and gap formation on the ACL repair construct as well as ultimate strength were analyzed. Results: A statistical significance for peak loads over peak elongation was found between the CLS-ALD and all other reinforced groups (analysis of covariance, P < .001). Accordingly, the adjustable repair technique showed improved load-bearing capability with the internal brace compared with all other fixed repair groups and revealed significantly higher loads than the knotted single-CL group. Also, significantly reduced gap formation was found for the CLS-ALD compared with all other groups ( P < .001), with no gap formation up to 150 N with a final gap of 0.85 ± 0.31 mm at 350 N. A significantly higher ultimate failure load (866.2 ± 104.0 N; P < .001) was found for the button-fixed internal brace group compared with all other groups. Conclusion: Internal bracing had a crucial role in improving the stabilization potential of ACL repair at loads occurring during normal daily activity. The added strength of the internal brace allowed for reducing peak loads on the ACL repair construct as well as restricting gap formation to below 3 mm at loads up to 350 N. Clinical Relevance: Improvements in the mechanical characteristics of current ACL repair techniques that enable reduced gap formation and allow for early range of motion and accelerated rehabilitation may strengthen the self-healing response with the formation of stable scar tissue.
Background: Biomechanical studies have compared augmented primary repair with internal bracing versus reconstruction techniques of the anterior ulnar collateral ligament (aUCL) in the elbow. However, aUCL repair alone has not been compared with augmented repair or reconstruction techniques. Hypothesis: Internal bracing of aUCL repair provides improved time-zero stabilization in terms of gap formation, torsional stiffness, and residual torque compared with both repair alone and the modified docking technique, with enhanced valgus stability restoration to that of the native ligament. Study Design: Controlled laboratory study. Methods: We randomized 8 matched pairs of cadaveric elbows to undergo either augmented aUCL repair or a modified docking technique through use of the palmaris longus tendon. Valgus laxity testing was consecutively performed at 90° of flexion on the intact, torn, and repaired conditions as well as the previously assigned techniques. First, intact elbows were loaded up to 10 N·m valgus torque to evaluate time-zero ligament rotations at valgus moments of 2.5, 5.0, 7.5, and 10 N·m. Rotation controlled cycling was performed (total 1000 cycles) for each surgical condition. Gap formation, stiffness, and residual torque were analyzed. Finally, these elbows and 8 additional intact elbows underwent torque to failure testing (30 deg/min). Results: Repair alone revealed low torsional resistance and gapping, similar to the torn state. The augmented repair technique showed significantly higher torsional stiffness ( P < .001) and residual torque ( P < .001) compared with all other conditions and restored native function. Although reconstruction revealed similar initial stiffness and residual torque compared with an intact ligament, a steady decrease of torsional resistance led to a completely loose state at higher valgus rotations. Analysis of covariance between all groups showed significantly less gap formation for augmented repair ( P < .001). The native failure load and stiffness were significantly higher and were similar to those of augmented repair ( P = .766). Conclusion: Internal bracing of aUCL repair restored valgus stability to the native state with statistically improved torsional resistance, loading capability, and gap formation compared with reconstruction, especially at the upper load range of native aUCL function in the elbow. Clinical Relevance: We found that aUCL repair with an internal brace effectively improves time-zero mechanical characteristics and may provide stabilized healing with accelerated and reliable recovery without the need for a tendon graft.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.