Anterior cruciate ligament (ACL) tears are among the most common sports-related injuries. Although studies have reported reliable outcomes with allograft tissue, several studies have shown a higher failure rate in younger patients. Although ACL graft augmentation has been met with varying levels of success, internal bracing of an allograft represents a promising area in ACL reconstruction. The purpose of this article is to detail allograft preparation involving a collagen-coated, ultrahigh-molecular-weight polyethylene/polyester suture tape as an internal brace augmentation for ACL reconstruction using the all-inside ACL GraftLink Technique (Arthrex, Naples, FL).
Internal bracing for anterior cruciate ligament (ACL) surgery is a relatively new concept. The purpose of this study was to evaluate the effects of an “independent” button-fixed internal brace on the biomechanical properties of ACL reconstruction in a full-construct experimental model. Three groups (n = 10 each) were tested in a full-construct porcine-bone model with human bone–patellar tendon–bone allografts using different reconstruction techniques: interference screw fixation on femur and tibia (S-S group), adjustable-loop device (ALD) fixation on the femur with tibial interference screw without suture tape (ALD-S group), and with internal brace (ALD-S-IB group). Measured outcomes included cyclic displacement, stiffness, and ultimate load to failure. The ALD-S-IB group (2.9 ± 0.8 mm) displaced significantly less than the ALD-S (4.2 ± 0.9 mm; p = 0.015) and S-S group (4.3 ± 1.1 mm; p = 0.017). No significant difference was found between the ALD-S and the S-S group. Construct stiffness was significantly higher for the ALD-S-IB group (156 ± 23 N/mm) and the ALD-S group (122 ± 28 N/mm) than for the S-S group (104 ± 40 N/mm; p = 0.003 and p = 0.0042), but there was no significant difference between both ALD groups. Similarly, ultimate loads in the ALD-S-IB (758 ± 128 N) and the ALD-S groups (628 ± 223 N) were significantly greater than in the S-S group (416 ± 167 N; p < 0.001 and p = 0.025), but there was no significant difference between ALD groups. Adding an internal brace reinforcement to an ALD in a full-construct experimental model significantly decreased cyclic displacement by 31% without increasing construct stiffness or ultimate load significantly. These results indicate that suture tape internal bracing of bone–patellar tendon–bone allograft ACL reconstruction decreases cyclic displacement during experimental testing, which has clinical implications regarding initial construct stability.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.