Three experimental techniques based on automatic swept-frequency network and impedance analysers were used to measure the dielectric properties of tissue in the frequency range 10 Hz to 20 GHz. The technique used in conjunction with the impedance analyser is described. Results are given for a number of human and animal tissues, at body temperature, across the frequency range, demonstrating that good agreement was achieved between measurements using the three pieces of equipment. Moreover, the measured values fall well within the body of corresponding literature data.
A parametric model was developed to describe the variation of dielectric properties of tissues as a function of frequency. The experimental spectrum from 10 Hz to 100 GHz was modelled with four dispersion regions. The development of the model was based on recently acquired data, complemented by data surveyed from the literature. The purpose is to enable the prediction of dielectric data that are in line with those contained in the vast body of literature on the subject. The analysis was carried out on a Microsoft Excel spreadsheet. Parameters are given for 17 tissue types.
The dielectric properties of tissues have been extracted from the literature of the past five decades and presented in a graphical format. The purpose is to assess the current state of knowledge, expose the gaps there are and provide a basis for the evaluation and analysis of corresponding data from an on-going measurement programme.
The influence of the user's hand holding a mobile phone to the ear on the peak spatial-average Specific Absorption Rate (psSAR) averaged over any 1 g and 10 g of tissue in the head is investigated. This study is motivated by recent reports that found substantial increases in psSAR by the presence of the hand in some cases. Current measurement standards prescribe the measurement of SAR in a head phantom without a hand present. The mechanisms of interaction between the hand and mobile phone models are studied. Simulations and measurements at 900 and 1800 MHz have been conducted to complement the understanding of the hand grip parameters leading to higher SAR in the head. Numerical simulations were conducted on four mobile phone models, and parameters such as the palm-phone distance and hand position were varied. Measurements of 46 commercial mobile phones were made, and the maximum psSAR with different hand positions and palm-phone distances was recorded. Both simulations and measurements have found increases in the psSAR in the head of at least 2.5 dB due to the presence of the hand. Furthermore, the psSAR is sensitive to the hand grip, i.e., the variations can exceed 3 dB.
ChemInform is a weekly Abstracting Service, delivering concise information at a glance that was extracted from about 100 leading journals. To access a ChemInform Abstract of an article which was published elsewhere, please select a “Full Text” option. The original article is trackable via the “References” option.
The results presented in this paper contribute to the investigations on the impact of the user's hand on the SAR in the head. Six laboratories have assessed the peak spatial-averaged SAR at 1950 MHz for 33 commercial phones with varied form factors, either held in one of 3 different hand phantoms or without a hand. This study confirms conclusions from previously published analyses that, in some cases, the head SAR can be enhanced by the presence of the hand.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.