DBD and DBD+SGK are equally effective treatment methods for canine SCCEDs. No differences in complication rates after one treatment were observed between DBD and DBD+SGK.
The cumulative incidence of RD in Boston Terrier and Shih Tzu reported here was in agreement with previously reported nonbreed specific percentages (2.7-8.4%). The cumulative incidence of glaucoma in this population of Boston Terriers and Shih Tzu was higher than previously reported nonbreed specific percentages (5.1-18.8%).
Considering there is an average of 7.5% normal diurnal variation in canine CCT, a 3.0% difference between Pentacam and SD-OCT values is likely not clinically relevant. However, Pentacam measurements were both statistically and clinically significantly different from UBM and SD-OCT measurements.
Objective: Iridocorneal angle (ICA) narrowing is a known risk factor for primary glaucoma in multiple species, but has not been described in companion rabbits. This study aimed to develop an ICA grading scheme for companion rabbits to enable early glaucoma predisposition diagnosis. Animals studied: Twenty healthy rabbits of varying breeds and ages. Procedures: Rabbits received complete ophthalmic examinations, including gonioscopy, and imaging of the ICA using spectral-domain optical coherence tomography (SD-OCT), Scheimpflug imaging (Pentacam ® HR), and high-resolution ultrasound (HRUS). Angle opening distance (AOD) and angle recess area (ARA) of the ICA were measured and assessed for agreement using a Bland-Altman analysis. A fivestage gonioscopy grading scheme was created, and Spearman-rank test assessed for correlation between gonioscopy grades and ICA measurements. Differences among age and sex were analyzed with a nonparametric ANOVA and Wilcoxon rank-sum test, respectively. Results: Analysis revealed AOD medians of 0.28mm for SD-OCT [95% CI: 0.24-0.31], 0.20mm for Pentacam ® HR [95% CI: 0.18-0.21], and 0.25mm for HRUS [95% CI: 0.22-0.28]. The median ARA was 0.14mm 2 for SD-OCT [95% CI: 0.117-0.163], 0.09mm 2 for Pentacam ® HR [95% CI: 0.082-0.100], and 0.06mm 2 for HRUS [95% CI: 0.046-0.054]. The association between gonioscopy grade and SD-OCT ARA was significant (P < 0.05), and there was a significant difference (P < 0.001) between imaging modalities for both ARA and AOD. Conclusions: Gonioscopy grade correlated well with SD-OCT ARA. Therefore, SD-OCT is recommended as a noncontact method for evaluating companion rabbit ICA.Each imaging device should not be used interchangeably for ICA evaluation. K E Y W O R D S gonioscopy, iridocorneal angle, rabbit, Scheimpflug imaging, SD-OCT, ultrasound | 835 LI PUMA et AL.
This study evaluated cataracts in wild boar exposed to chronic low-dose radiation. We examined wild boar from within and outside the Fukushima Exclusion Zone for nuclear, cortical, and posterior subcapsular (PSC) cataracts in vivo and photographically. Plausible upper-bound, lifetime radiation dose for each boar was estimated from radioactivity levels in each animal's home range combined with tissue concentrations of 134+137 Cesium. Fifteen exposed and twenty control boar were evaluated. There were no significant differences in overall prevalence or score for cortical or PSC cataracts between exposed and control animals. Nuclear (centrally located) cataracts were significantly more prevalent in exposed boar (p < 0.05) and had statistically higher median scores. Plausible upper-bound, lifetime radiation dose ranged from 1 to 1,600 mGy in exposed animals, with no correlation between dose and cortical or PSC score. While radiation dose and nuclear score were positively associated, the impact of age could not be completely separated from the relationship. Additionally, the clinical significance of even the highest scoring nuclear cataract was negligible. Based on the population sampled, wild boar in the Fukushima Exclusion Zone do not have a significantly higher prevalence or risk of cortical or PSC cataracts compared to control animals.
Objective
To describe and compare normative anterior segment parameters between canine age groups using the Pentacam® HR Scheimpflug camera (Pentacam).
Animals Studied
Thirty‐six sedated dogs (60 eyes) of varying ages and breeds were imaged with the Pentacam; only nondiseased anterior segments were included.
Procedures
Dogs were divided into three age groups: Group 1 (1‐5 years), Group 2 (6‐10 years), and Group 3 (11‐15 years). Values assessed included central corneal thickness (CCT), anterior and posterior corneal elevation (ACE/PCE), anterior and posterior corneal curvature metrics, corneal volume (CV), anterior and posterior corneal astigmatism (AA/PA), anterior chamber depth (ACD), anterior chamber volume (ACV), and anterior chamber angle (ACA). Tukey‐adjusted pairwise comparisons were performed.
Results
Overall CCT (mean ± SD) was 631.07 ± 59.91 µm. Central corneal thickness was 608.60 ± 48.63 µm for Group 1, 648.57 ± 51.06 µm for Group 2, and 635.37 ± 73.71 µm for Group 3. Anterior corneal elevation (ACE) measured 9.08 ± 0.58 mm, PCE measured 8.04 ± 0.50 mm, and CV was 58.13 ± 5.39 mm3. Astigmatism values were 1.34 ± 0.94 D for AA and 0.46 ± 0.44 D for PA. Anterior chamber values were 3.76 ± 0.56 mm for ACD, 383.68 ± 66.24 mm3 for ACV, and 23.62 ± 29.33˚ for ACA. Significant differences were found between Groups 1 and 2 for CV (55.08 ± 4.08 mm3 and 60.32 ± 4.19 mm3, respectively), (P = 0.02).
Conclusions
Corneal volume significantly increased between Group 1 and Group 2. Central corneal thickness increased from Group 1 to Group 3, but was not significant with the current sample size. There were no other differences between age groups.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.