PurposeThe purpose of this study was to investigate the level of clinical image quality of panoramic radiographs and to analyze the parameters that influence the overall image quality.Materials and MethodsKorean dental clinics were asked to provide three randomly selected panoramic radiographs. An oral and maxillofacial radiology specialist evaluated those images using our self-developed Clinical Image Quality Evaluation Chart. Three evaluators classified the overall image quality of the panoramic radiographs and evaluated the causes of imaging errors.ResultsA total of 297 panoramic radiographs were collected from 99 dental hospitals and clinics. The mean of the scores according to the Clinical Image Quality Evaluation Chart was 79.9. In the classification of the overall image quality, 17 images were deemed 'optimal for obtaining diagnostic information,' 153 were 'adequate for diagnosis,' 109 were 'poor but diagnosable,' and nine were 'unrecognizable and too poor for diagnosis'. The results of the analysis of the causes of the errors in all the images are as follows: 139 errors in the positioning, 135 in the processing, 50 from the radiographic unit, and 13 due to anatomic abnormality.ConclusionPanoramic radiographs taken at local dental clinics generally have a normal or higher-level image quality. Principal factors affecting image quality were positioning of the patient and image density, sharpness, and contrast. Therefore, when images are taken, the patient position should be adjusted with great care. Also, standardizing objective criteria of image density, sharpness, and contrast is required to evaluate image quality effectively.
PurposeThe current study investigates the feasibility of a platform for a nationwide dose monitoring system for dental radiography. The essential elements for an unerring system are also assessed.Materials and MethodsAn intraoral radiographic machine with 14 X-ray generators and five sensors, 45 panoramic radiographic machines, and 23 cone-beam computed tomography (CBCT) models used in Korean dental clinics were surveyed to investigate the type of dose report. A main server for storing the dose data from each radiographic machine was prepared. The dose report transfer pathways from the radiographic machine to the main sever were constructed. An effective dose calculation method was created based on the machine specifications and the exposure parameters of three intraoral radiographic machines, five panoramic radiographic machines, and four CBCTs. A viewing system was developed for both dentists and patients to view the calculated effective dose. Each procedure and the main server were integrated into one system.ResultsThe dose data from each type of radiographic machine was successfully transferred to the main server and converted into an effective dose. The effective dose stored in the main server is automatically connected to a viewing program for dentist and patient access.ConclusionA patient radiation dose monitoring system is feasible for dental clinics. Future research in cooperation with clinicians, industry, and radiologists is needed to ensure format convertibility for an efficient dose monitoring system to monitor unexpected radiation dose.
PurposeThe aim of this study was to provide sex-matched three-dimensional (3D) statistical shape models of the mandible, which would provide cephalometric parameters for 3D treatment planning and cephalometric measurements in orthognathic surgery.Materials and MethodsThe subjects used to create the 3D shape models of the mandible included 23 males and 23 females. The mandibles were segmented semi-automatically from 3D facial CT images. Each individual mandible shape was reconstructed as a 3D surface model, which was parameterized to establish correspondence between different individual surfaces. The principal component analysis (PCA) applied to all mandible shapes produced a mean model and characteristic models of variation. The cephalometric parameters were measured directly from the mean models to evaluate the 3D shape models. The means of the measured parameters were compared with those from other conventional studies. The male and female 3D statistical mean models were developed from 23 individual mandibles, respectively.ResultsThe male and female characteristic shapes of variation produced by PCA showed a large variability included in the individual mandibles. The cephalometric measurements from the developed models were very close to those from some conventional studies.ConclusionWe described the construction of 3D mandibular shape models and presented the application of the 3D mandibular template in cephalometric measurements. Optimal reference models determined from variations produced by PCA could be used for craniofacial patients with various types of skeletal shape.
The objective of this study was to perform the quantitative three-dimensional analysis of the patients' movements at the different time points during the simulated acquisition of cephalometric radiographs. Fifty-three subjects (32 men, 21 women) were divided into four groups according to their age (Group 1: 9-12, Group 2: 13-19, Group 3: 20-25, and Group 4: 26-30 years old). The experiment (Exp) consisted in providing the subjects with three different kinds of verbal instructions as follows; Exp 1: they were simply instructed not to move, Exp 2: detailed instructions were provided, and Exp 3: they were specifically instructed to clench their molars. The amount of their movement during the 20 s of the cephalomatric X-ray exposure was measured using an optical marker and tracker. The maximum movement was analyzed three-dimensionally at 0.5, 2, 5, 10, 15, and 20 s. There was minimal vibrating movement every 0.3-0.5 s and relatively large movement every 3-5 s. The youngest group showed the largest amount of movement among the four age groups, and their movement was more significant in the up and down direction (pG0.05). There was no significant difference in the amount of movement according to the instructions. The longer exposure time showed the larger amount of the movement. Children can show the significant movements during X-ray taking, and the longer exposure time can also result in the larger movement during acquisition of cephalometric radiographs. Therefore, the shorter exposure time is recommended in order to improve image quality.
PurposeThe aim of this study was to determine whether the panoramic mandibular index (PMI) is useful for assessing bone mineral density. We also analyzed the potential correlations between PMI parameters and patient age.Materials and MethodsFour observers measured the PMI of both sides of the mental foramen using a picture archiving and communication system and images in the Digital Imaging and Communications in Medicine format. They studied 300 panoramic radiographic images of patients belonging to the following age groups: 40–49 years, 50–59 years, 60–69 years, 70–79 years, and 80–89 years. The observers were allowed to zoom in or out and to adjust the contrast of the images. Further, they were instructed to record the reasons for any measurements that could not be made. Then, we conducted a reliability analysis of the measured PMI and assessed the correlations between different patient age groups and the 3 parameters used for determining the PMI from the available data.ResultsAmong the 600 data items collected, 23 items were considered unmeasurable by at least 1 observer for the following 4 reasons: postoperative state, lesion, unidentified mental foramen, and alveolar bone loss. The intraobserver reproducibility of the measurable data was 0.611-0.752. The mandibular cortical width (MCW) decreased significantly as patient age increased.ConclusionPMI had limited usability when the margin of the mental foramen was not clear. In contrast, MCW, a parameter used for determining the PMI, had fewer drawbacks than the PMI with respect to bone mineral density measurements and exhibited a significant correlation with patient age.
PurposeAn individual surgical stent fabricated from computed tomography (CT) data, called a CT-guided stent, would be useful for accurate installation of implants. The purpose of the present study was to introduce a newly developed CT-guided stent with a simple design and evaluate the accuracy of the stent placement.Materials and MethodsA resin template was fabricated from a hog mandible and a specially designed plastic plate, with 4 metal balls inserted in it for radiographic recognition, was attached to the occlusal surface of the template. With the surgical stent applied, CT images were taken, and virtual implants were placed using software. The spatial positions of the virtually positioned implants were acquired and implant guiding holes were drilled into the surgical stent using a specially designed 5-axis drilling machine. The surgical stent was placed on the mandible and CT images were taken again. The discrepancy between the central axis of the drilled holes on the second CT images and the virtually installed implants on the first CT images was evaluated.ResultsThe deviation of the entry point and angulation of the central axis in the reference plane were 0.47±0.27 mm, 0.57±0.23 mm, and 0.64±0.16°, 0.57±0.15°, respectively. However, for the two different angulations in each group, the 20° angulation showed a greater error in the deviation of the entry point than did the 10° angulation.ConclusionThe CT-guided template proposed in this study was highly accurate. It could replace existing implant guide systems to reduce costs and effort.
Purpose: This is a descriptive correlation study to identify self-esteem, job satisfaction, and turnover intention among ship-building supply workers. Methods: The subjects were 199 ship-building supply workers at two small & medium-sized ship-building supply companies in K city. The data were collected from March 1st through 31st, 2013. The collected data were analyzed using the SAS program through t-test, ANOVA, Scheffé test, and Pearson's correlation coefficients. Results: There was a positive correlation between self-esteem and job satisfaction (r=.29, p<.001), a negative correlation between self-esteem and turnover intention (r=-.20, p<.001). Also there was a negative correlation between job satisfaction and turnover intention (r= -.58, p<.001). Conclusion: This finding identified that the self-esteem and job satisfaction were an important variable related to the turnover intention. Therefore, organizational managers need to develop strategies for improving workers' self-esteem and job satisfaction to prevent and decrease worker's turnover intention.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.