Excessive and prolonged exposure to impact acceleration during running is associated with increased injury rate. Acute use of compressive garments has been speculated to improve attenuation. However, it is unknown how longer interventions of compressive garments influence attenuation in running. 40 runners trained with compressive and placebo stockings for 3 weeks. Perception of comfort, stride parameters (rate, length) and impact acceleration (head and tibial peak acceleration, magnitude, acceleration rate and attenuation) were measured every 5 min during a fatigue run (30 min at 80% of the individual's maximal aerobic speed). Compressive stockings reduced tibial peak acceleration and magnitude compared to placebo stockings at every minute (p<0.05) except for the initial measurement (p>0.05). Moreover, compressive stockings led to a lower rate of increase in tibial peak acceleration (14%, p<0.005) and magnitude (16%, p<0.001) as a result of the development of fatigue compared to placebo stockings (24% and 26% increase, p=0.014 and p=0.003, respectively). Similar perception of comfort was reported for both garments. Training with compressive stockings for 3 weeks reduced impact acceleration and the rate of increase in acceleration compared to placebo stockings. These findings suggest that compressive stockings may play a protective role by reducing impact accelerations during running.
Tibial accelerations have been associated with a number of running injuries. However, studies attaching the tibial accelerometer on the proximal section are as numerous as those attaching the accelerometer on the distal section. This study aimed to investigate whether accelerometer location influences acceleration parameters commonly reported in running literature. To fulfil this purpose, 30 athletes ran at 2.22, 2.78 and 3.33 m · s with three accelerometers attached with double-sided tape and tightened to the participants' tolerance on the forehead, the proximal section of the tibia and the distal section of the tibia. Time-domain (peak acceleration, shock attenuation) and frequency-domain parameters (peak frequency, peak power, signal magnitude and shock attenuation in both the low and high frequency ranges) were calculated for each of the tibial locations. The distal accelerometer registered greater tibial acceleration peak and shock attenuation compared to the proximal accelerometer. With respect to the frequency-domain analysis, the distal accelerometer provided greater values of all the low-frequency parameters, whereas no difference was observed for the high-frequency parameters. These findings suggest that the location of the tibial accelerometer does influence the acceleration signal parameters, and thus, researchers should carefully consider the location they choose to place the accelerometer so that equivalent comparisons across studies can be made.
Periodized functional resistance training decreased pain and disability and improved HRQOL, balance and physical fitness in females with CLBP, and can thus be used safely in this population.
Controversy exists whether custom-made insoles are more effective in reducing plantar loading compared to prefabricated insoles. Forty recreational athletes ran using custom-made, prefabricated, and the original insoles of their running shoes, at rest and after a fatigue run. Contact time, stride rate, and plantar loading parameters were measured. Neither the insole conditions nor the fatigue state modified contact time and stride rate. Addressing prevention of running injuries, post-fatigue loading values are of great interest. Custom-made insoles reduced the post-fatigue loading under the hallux (92 vs. 130 kPa, P < 0.05), medial midfoot (70 vs. 105 kPa, P < 0.01), and lateral midfoot (62 vs 96 kPa, P < 0.01). Prefabricated insoles provoked reductions in post-fatigue loading under the toes (120 vs. 175 kPa, P < 0.05), medial midfoot (71 vs. 105 kPa, P < 0.01), and lateral midfoot (68 vs. 96 kPa, P < 0.01). Regarding both study insoles, custom-made insoles reduced by 31% and 54% plantar loading under the medial and lateral heel compared to the prefabricated insoles. Finally, fatigue state did not influence plantar loading regardless the insole condition. In long-distance races, even a slight reduction in plantar loading at each foot strike may suppose a significant decrease in the overall stress experienced by the foot, and therefore the use of insoles may be an important protective mechanism for plantar overloading.
Each time the foot contacts the ground during running there is a rapid deceleration that results in a shock wave that is transmitted from the foot to the head. The fatigue of the musculoskeletal system during running may decrease the ability of the body to absorb those shock waves and increase the risk of injury. Insoles are commonly prescribed to prevent injuries, and both custom-made and prefabricated insoles have been observed to reduce shock accelerations during running. However, no study to date has included a direct comparison of their behaviour measured over the same group of athletes, and therefore great controversy still exists regarding their effectiveness in reducing impact loading during running. The aim of the study was to analyse the acute differences in stride and shock parameters while running on a treadmill with custom-made and prefabricated insoles. Stride parameters (stride length, stride rate) and shock acceleration parameters (head and tibial peak acceleration, shock magnitude, acceleration rate, and shock attenuation) were measured using two triaxial accelerometers in 38 runners at 3.33 m/s before and after a 15-min intense run while using the sock liner of the shoe (control condition), prefabricated insoles and custom-made insoles. No differences in shock accelerations were found between the custom-made and the control insoles. The prefabricated insoles increased the head acceleration rate (post-fatigue, p = 0.029) compared to the control condition. The custom-made reduced tibial (pre-fatigue, p = 0.041) and head acceleration rates (pre-fatigue and post-fatigue, p = 0.01 and p = 0.046) compared to the prefabricated insoles. Neither the stride nor the acceleration parameters were modified as a result of the intense run. In the present study, the acute use of insoles (custom-made, prefabricated) did not reduce shock accelerations compared to the control insoles. Therefore, their effectiveness at protecting against injuries associated with elevated accelerations is not supported and remains unclear.
The presence of fatigue has been shown to modify running biomechanics. Overall in terms of gender, women are at lower risk than men for sustaining running-related injuries, although it depends on the factors taken into account. One possible reason for these differences in the injury rate and location might be the dissimilar running patterns between men and women. The purpose of this study was to determine the effect of fatigue and gender on the kinematic and ground reaction forces (GRF) parameters in recreational runners. Fifty-seven participants (28 males and 29 females) had kinematic and GRF variables measured while running at speed of 3.3 m s−1 before and after a fatigue test protocol. The fatigue protocol included (1) a running Course-Navette test, (2) running up and down a flight of stairs for 5 min, and (3) performance of alternating jumps on a step (five sets of 1 minute each with 30 resting seconds between the sets). Fatigue decreased dorsiflexion (14.24 ± 4.98° in pre-fatigue and 12.65 ± 6.21° in fatigue condition, p < 0.05) at foot strike phase in females, and plantar flexion (−19.23 ± 4.12° in pre-fatigue and −18.26 ± 5.31° in fatigue condition, p < 0.05) at toe-off phase in males. These changes led to a decreased loading rate (88.14 ± 25.82 BW/s in pre-fatigue and 83.97 ± 18.83 BW/s in fatigue condition, p < 0.05) and the impact peak in females (1.95 ± 0.31 BW in pre-fatigue and 1.90 ± 0.31 BW in fatigue condition, p < 0.05), and higher peak propulsive forces in males (−0.26 ± 0.04 BW in pre-fatigue and −0.27 ± 0.05 BW in fatigue condition, p < 0.05) in the fatigue condition. It seems that better responses to impact under a fatigue condition are observed among women. Further studies should confirm whether these changes represent a strategy to optimize shock attenuation, prevent running injuries and improve running economy.
The perceived level of comfort of footwear is considered to be a protective measure of the potential risk of running injuries. We here compared runners' perception of comfort of custom-made and prefabricated orthoses while running. We found that even though custom-made orthoses are closely matched to each individual's foot, such customisation does not necessarily imply greater comfort.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.