wide-necked bifurcation aneurysms (wNBAs) make up 26-36% of all brain aneurysms. Treatments for wNBAs pose unique challenges due to the need to preserve major bifurcation vessels while achieving a durable occlusion of the aneurysm. intrasaccular flow disruption is an innovative technique for the treatment of wNBAs. The woven endoBridge (weB) device is the only United States Food and Drug Administration approved intrasaccular flow disruption device. in this review article we discuss various aspects of treating wNBAs with the weB device, including indications for use, aneurysm/device selection strategies, antiplatelet therapy requirement, procedural technique, potential complications and bailouts, and management strategies for residual/recurrent aneurysms after initial weB treatment. Aneurysm height axis-parent artery angleBoth the dome size and the angle between the long axis of the aneurysm and the parent artery play on June 9, 2020 by guest. Protected by copyright.
Background and purposeThe Pipeline Embolization Device (PED) has become a routine first-line option for treatment of intracranial aneurysms (IAs). We assessed the early safety and technical success of a new version of PED, Pipeline Flex Embolization Device with Shield Technology (Pipeline Shield), which has the same design and configuration but has been modified to include a surface synthetic biocompatible polymer.Materials and methodsThe Pipeline Flex Embolization Device with Shield Technology (PFLEX) study is a prospective, single-arm, multicenter study for the treatment of unruptured IAs using Pipeline Shield. The primary study endpoints included the occurrence of major stroke in the territory supplied by the treated artery or neurologic death at 1 year post-procedure. Secondary endpoints included the rate of Pipeline Shield-related or procedure-related serious or non-serious adverse events. Analyses were conducted to evaluate early safety findings in the 30-day post-procedure period as well as technical procedural success outcomes.ResultsFifty patients with 50 unruptured target IAs were enrolled. Mean aneurysm diameter was 8.82±6.15 mm. Thirty-eight aneurysms (76%) were small (<10 mm). Device deployment was technically successful with 98% of devices. Complete wall apposition was achieved immediately post-procedure in 48 cases (96%). No major strokes or neurologic deaths were reported in the 30-day post-procedure period.ConclusionsThe results of this first experience with the new Pipeline Flex corroborate the early safety of the device. Mid-term and long-term follow-up examinations will provide data on safety outcomes at the 6-month and 1-year follow-up periods. Clinical trial registrationNCT02390037.
PurposeThe Pipeline Embolization Device (PED) is a routine first-line treatment option for intracranial aneurysms (IAs). The Pipeline Flex Embolization Device with Shield Technology (Pipeline Shield) is an updated version of the PED which has been modified to include a surface phosphorylcholine biocompatible polymer. Its early technical success and safety have been reported previously. Here, we assessed the long-term safety and efficacy of the Pipeline Shield for the treatment of IAs.Materials and methodsThe Pipeline Flex Embolization Device with Shield Technology (PFLEX) study was a prospective, single-arm, multicenter study for the treatment of unruptured IAs using the Pipeline Shield. The primary endpoint was a major stroke in the territory supplied by the treated artery or neurologic death at 1-year post-procedure. Angiographic outcomes were also assessed by an independent radiology laboratory at 6 months and 1 year.ResultsFifty patients (mean age, 53 years; 82% female) with 50 unruptured IAs were treated. Mean aneurysm diameter was 8.82±6.15 mm. Of the target aneurysms, 38/50 (76%) were small (<10 mm), 11/50 (22%) were large (≥10 and<25 mm), and 1/50 (2%) was giant (≥25 mm). Forty-seven (94%) were located in the internal carotid artery and three (6%) in the vertebral artery. At 1-year post-procedure, no major strokes or neurologic deaths were reported, and complete occlusion was achieved in 27/33 (81.8%). There were no instances of aneurysm recurrence or retreatment.ConclusionsOur 1-year follow-up concerning angiographic and safety outcomes corroborate previous evidence that the Pipeline Shield is a safe and effective treatment for IAs.Trial registration numberNCT02390037
PHIL liquid embolic agent appears to be an excellent alternative embolic material with certain advantages compared with other available liquid embolic agents. Further studies are required to fully evaluate its safety and efficacy.
OBJECTIVE The Woven Endobridge (WEB) device has been in clinical use for the treatment of brain aneurysms for the past 4 years. Observational studies to assess clinical outcome and related complications have been published. Clear evidence is required to better understand the safety profile of the WEB device. The authors here present a multicenter series that provides a detailed safety analysis focused on patient selection, procedural events, and technical issues of treated patients throughout the United Kingdom (UK). METHODS A nationwide password-protected database was set up to collect anonymous information across the UK (14 centers). Complications and clinical outcome were analyzed for the initial 109 patients (112 procedures). An independent root cause analysis classified the complications into groups (procedural, disease, device, ancillary device, and other). The modified Rankin Scale (mRS) was used as a marker of clinical outcome. RESULTS Each of the 109 patients had 1 aneurysm suitable for WEB treatment (109 aneurysms). Three patients had 2 procedures, making a total of 112 procedures performed. Eight procedures were abandoned because of access issues; 2 patients went on to have a successful procedure. All 109 patients had a preprocedure and discharge mRS scores recorded. One hundred patients had a recorded mRS score from a > 3-month follow-up. Deployment of the WEB device was successful in 103 (94.5%) of 109 patients and 104 (92.9%) of 112 procedures. One patient had 2 successful WEB procedures on separate occasions. Patients without a successfully implanted WEB device were included in the analysis. Selection analysis showed that the average patient age was 56.5 years among 34 men and 75 women. The percentage of incidental aneurysms was 58.7%, acute 16.5%, symptomatic 18.3%, and recurrent 6.4%. Further results analysis showed that 40 (36.7%) of 109 patients had recorded adverse events, including those unrelated to the WEB device. Events that could be related to the WEB device numbered 17 (15.6%) among the 109 patients. Two patients with device-related complications were symptomatic. Overall, 11 patients (10.1%) had persistent clinical sequelae. Thromboembolism was the most prevalent event, affecting 15.6% of the patients (17 of 109), and 6.4% of the patients (7 of 109) with a thromboembolism were symptomatic. Overall mortality before discharge was 0% and at the > 3-month follow-up was 5% (5 of 100 patients). Morbidity was defined as an mRS score increase to > 2. Overall morbidity at discharge was 1.8% (2 of 109) and at the > 3-month follow-up was 6% (6 of 100). No device-related morbidity or mortality was associated with this group. CONCLUSIONS The UK data show that the WEB device is safe for clinical use. Thromboembolic complication adds a risk that should be minimized with appropriate anticoagulation and correct sizing of the device. There is scope for further evaluation and standardization of an anticoagulation regimen for the WEB device.
Background: The impact on clinical outcomes of patient selection using perfusion imaging for endovascular thrombectomy (EVT) in patients with acute ischemic stroke presenting beyond 6 hours from onset remains undetermined in routine clinical practice. Methods: Patients from a national stroke registry that underwent EVT selected with or without perfusion imaging (noncontrast computed tomography/computed tomography angiography) in the early (<6 hours) and late (6–24 hours) time windows, between October 2015 and March 2020, were compared. The primary outcome was the ordinal shift in the modified Rankin Scale score at hospital discharge. Other outcomes included functional independence (modified Rankin Scale score ≤2) and in-hospital mortality, symptomatic intracerebral hemorrhage, successful reperfusion (Thrombolysis in Cerebral Infarction score 2b–3), early neurological deterioration, futile recanalization (modified Rankin Scale score 4–6 despite successful reperfusion) and procedural time metrics. Multivariable analyses were performed, adjusted for age, sex, baseline stroke severity, prestroke disability, intravenous thrombolysis, mode of anesthesia (Model 1) and including EVT technique, balloon guide catheter, and center (Model 2). Results: We included 4249 patients, 3203 in the early window (593 with perfusion versus 2610 without perfusion) and 1046 in the late window (378 with perfusion versus 668 without perfusion). Within the late window, patients with perfusion imaging had a shift towards better functional outcome at discharge compared with those without perfusion imaging (adjusted common odds ratio [OR], 1.45 [95% CI, 1.16–1.83]; P =0.001). There was no significant difference in functional independence (29.3% with perfusion versus 24.8% without; P =0.210) or in the safety outcome measures of symptomatic intracerebral hemorrhage ( P =0.53) and in-hospital mortality (10.6% with perfusion versus 14.3% without; P =0.053). In the early time window, patients with perfusion imaging had significantly improved odds of functional outcome (adjusted common OR, 1.51 [95% CI, 1.28–1.78]; P =0.0001) and functional independence (41.6% versus 33.6%, adjusted OR, 1.31 [95% CI, 1.08–1.59]; P =0.006). Perfusion imaging was associated with lower odds of futile recanalization in both time windows (late: adjusted OR, 0.70 [95% CI, 0.50–0.97]; P =0.034; early: adjusted OR, 0.80 [95% CI, 0.65–0.99]; P =0.047). Conclusions: In this real-world study, acquisition of perfusion imaging for EVT was associated with improvement in functional disability in the early and late time windows compared with nonperfusion neuroimaging. These indirect comparisons should be interpreted with caution while awaiting confirmatory data from prospective randomized trials.
PHIL appears to be safe and effective for endovascular treatment of cranial dural arteriovenous fistulas. Short-term angiographic and clinical results are comparable with those of Onyx, with the added advantage of easier preparation and improved homogeneous cast visualization. The use of iodine as a radio-opacifier also produces considerably less artifacts on CT compared with tantalum-based embolic materials.
BackgroundThe first and second generations of the Pipeline Embolization Device (PED) have been widely adopted for the treatment of intracranial aneurysms (IAs) due to their high associated occlusion rates and low morbidity and mortality. The objective of this study was to evaluate the safety and effectiveness of the third- generation Pipeline Shield device (PED-Shield) for the treatment of IAs.MethodsThe SHIELD study was a prospective, single-arm, multicenter, post-market, observational study evaluating the PED-Shield device for the treatment of IAs. The primary efficacy endpoint was complete aneurysm occlusion without significant parent artery stenosis or retreatment at 1-year post-procedure and the primary safety endpoint was major stroke in the territory supplied by the treated artery or neurological death.ResultsOf 205 subjects who consented across 21 sites, 204 subjects with 204 target aneurysms were ultimately treated (mean age 54.8±12.81 years, 81.4% [166/204] female). Technical success (ie, deployment of the PED-Shield) was achieved in 98.0% (200/204) of subjects with a mean number of 1.1±0.34 devices per subject and a single device used in 86.8% (177/204) of subjects. The primary effectiveness endpoint was met in 71.7% (143/200) of subjects while the primary safety endpoint occurred in six (2.9%) subjects, two (1.0%) of which led to neurological death.ConclusionsThe findings of the SHIELD study support the safety and effectiveness of the PED-Shield for IA treatment, evidenced by high occlusion rates and low rates of neurological complications in the study population.Clinical trial registration-URLhttp://www.clinicaltrials.gov. Unique identifier: NCT02719522.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.