Locator and ball and socket attachments induce equivalent stresses on bone surrounding implants. Locator attachment performance was superior to that of the ball and socket attachment in the implants, nylon caps, and overdenture. Locator attachments are highly recommended and can increase the interval between successive maintenance sessions.
AIM:This study deeply investigates the effect of dental implant threading and material selection on the mandibular bone under two different crown materials (Translucent Zirconia and Porcelain fused to metal).METHODS:Two different designs of single piece dental implants were supporting dummy crown above simplified bone geometry in two finite element models. Models components were created by general-purpose CAD/CAM engineering package and then assembled inside ANSYS before meshing and assigning materials. Compressive loading of 100 N and 45º oblique loading of 50 N were tested.RESULTS:Twenty-four case studies were analysed, and their results were compared. Micro thread reduces implant maximum Von Mises stress by about 50 to 70% than regular thread one. Oblique loading of 50 N will produce 4 to 5 times more maximum Von Mises values on implant body than 100 N vertical loading. Zero or negligible effect on the cortical bone was recorded when exchanging the tested crown material. Although titanium implant can also reduce cortical bone, Von Mises stress by 50 to 100% in comparison to reinforced PEKK (poly ether-ketone-ketone) or PEEK (poly-ether-ether-ketone).CONCLUSIONS:Reinforced PEKK and PEEK implants can represent a good alternative to titanium implants. Zirconia crown distributes the applied load better than Porcelain fused to a metal one. Regardless of the implant material, an implant with the micro thread has superior behaviour in comparison to a regular one. Zirconia crown above titanium implant with the micro thread may represent the best option for patient bone.
In the present study, GTX and ProTaper as continuous rotating endodontic files were numerically compared with WaveOne reciprocating file using finite element analysis, aiming at having a low cost, accurate/trustworthy comparison as well as finding out the effect of instrument design and manufacturing material on its lifespan. Two 3D finite element models were especially prepared for this comparison. Commercial engineering CAD/CAM package was used to model full detailed flute geometries of the instruments. Multi-linear materials were defined in analysis by using real strain-stress data of NiTi and M-Wire. Non-linear static analysis was performed to simulate the instrument inside root canal at a 45° angle in the apical portion and subjected to 0.3 N.cm torsion. The three simulations in this study showed that M-Wire is slightly more resistant to failure than conventional NiTi. On the other hand, both materials are fairly similar in case of severe locking conditions. For the same instrument geometry, M-Wire instruments may have longer lifespan than the conventional NiTi ones. In case of severe locking conditions both materials will fail similarly. Larger cross sectional area (function of instrument taper) resisted better to failure than the smaller ones, while the cross sectional shape and its cutting angles could affect instrument cutting efficiency.
Objective: to study the effect of using two cement types, with three different thicknesses, on stress levels and distributions within bone around implant premolar using three-dimensional Finite Element Analysis techniques. Materials & methods: A three 3D Finite Element models were built for this purpose. Threaded titanium dental implant was implemented in simplified geometry for jaw bone. While the crown geometry, was acquired by 3D scanner. Two cement materials (Zinc phosphate, Glass Ionomer), with three values of cement layer thicknesses (20, 40, and 60 mm) were investigated. Twenty-four case studies were reported within this research. Each case was analyzed under vertical and oblique loading at Palatal Cusp Tip and Central Fossa. Results: Linear static stress analysis was performed. The results of the model showed the superiority of 60 mm thickness cement layer over the other two thicknesses. Conclusions: Using thicker cement layer increase its lifetime, in addition to reducing the cortical bone Von Mises stress. While, the effect of cement layer thickness and type on spongy bone, is negligible.
Aim: To evaluate the mechanical behavior of reciprocating endodontic files, comparing nickeltitanium (NiTi) and stainless steel 316L (St.St. 316L) as manufacturing material for such instruments. Methods: A three-dimensional finite element model was designed for this study. The simplified instrument model geometry was created on commercial CAD/CAM software. Real strain stress curves of St.St. 316L and NiTi were used in the analysis. Non-linear static analysis was performed to simulate the instrument inside root canal at an angle of 45° in the apical portion, and subjected to torsion of 0.3 N.cm. Results: Non-linear NiTi material showed super elasticity and high functionality in such applications. Very high levels of stress appeared in the file at 3 mm from the tip close to yield point. Conclusions: St. St. 316L is not suitable for manufacturing reciprocating instruments. Modeling of the instrument with equivalent circular cross-sectional area did not affect results quality. Reciprocating instruments have short lifespan, thus manufacturers recommend using one file per tooth. Reciprocating instruments are recommended for less experienced dentist.
This article touched, in brief, the recent advances in dental materials and geometric modelling in dental applications. Most common categories of dental materials as metallic alloys, composites, ceramics and nanomaterials were briefly demonstrated. Nanotechnology improved the quality of dental biomaterials. This new technology improves many existing materials properties, also, to introduce new materials with superior properties that covered a wide range of applications in dentistry. Geometric modelling was discussed as a concept and examples within this article. The geometric modelling with engineering Computer-Aided-Design (CAD) system(s) is highly satisfactory for further analysis or Computer-Aided-Manufacturing (CAM) processes. The geometric modelling extracted from Computed-Tomography (CT) images (or its similar techniques) for the sake of CAM also reached a sufficient level of accuracy, while, obtaining efficient solid modelling without huge efforts on body surfaces, faces, and gaps healing is still doubtable. This article is merely a compilation of knowledge learned from lectures, workshops, books, and journal articles, articles from the internet, dental forum, and scientific groups’ discussions.
Objective To study the effect of using different cement types under pediatric stainless-steel crown (SSC) around mandibular second primary molar using three-dimensional (3D) finite element analysis. Materials and Methods A 3D finite element model was built for pediatric mandibular molar by laser scanning of natural extracted tooth. Four types of cement (zinc phosphate, glass ionomer, resin-modified glass ionomer, and resin) of 200 μm layers thickness were tested under a stainless-steel crown of 130-μm thickness. Twelve case studies were reported within this research, as the applied load of 330 N was tested with three angulations: vertical, oblique at 45°, and laterally. Results Linear static stress analysis was performed. The resultant stresses and deformations' distribution patterns did not change with cement type, while the values were altered. All deformations and stresses were found within the normal range. Conclusions Analysis results indicated that using stiffer cement material increases tooth structure stresses and reduces crown body stresses and deformations, while bone was nearly insensitive to cement type.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
334 Leonard St
Brooklyn, NY 11211
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.