BackgroundExtra-articular proximal tibial fractures account for 5–11 % of all tibial shaft fractures. In recent years, closed reduction and minimally invasive plating and multidirectional locked intramedullary nailing have both become widely used treatment modalities for proximal and distal tibial metaphyseal fractures. This study was performed to compare plating and nailing options in proximal tibia extra-articular fractures.Materials and methodsThis randomized prospective clinical study was conducted on 58 skeletally mature patients with a closed extra-articular fracture of the proximal tibia treated with minimally invasive proximal tibial plating (PTP) or intramedullary nailing (IMN) by trained surgeons at a tertiary trauma center.ResultsPostoperative hospital stay (p = 0.035), time to full weight-bearing, and union time (p = 0.004) were significantly less in the IMN group than in the PTP group, but there was no clear advantage of either technique in terms of operative time (p = 0.082), infection rate (p = 0.738), range of motion of the knee (p = 0.462), or degrees of malunion and nonunion.ConclusionBoth implants have shown promising results in extra-articular proximal tibial fractures, and provide rigid fixation that prevents secondary fracture collapse.Level of evidenceLevel 2, randomized controlled trial.
Operative treatment of Hoffa fractures yields fairly good functional outcome. One must endeavor to achieve adequate intraoperative exposure and stable congruous articular reconstruction. Early aggressive physical therapy is a harbinger of optimal outcome.
PurposeTo compare two commonly used methods of temporary hemiepiphysiodesis (staples and figure of eight plate) in the management of coronal plane deformities of the knee in skeletally immature children.MethodsThis prospective study was conducted between November 2012 and November 2015. A total of 40 patients with 67 affected knee joints, having at least 1 year of skeletal growth remaining, were included in the study. Angular correction was measured by recording the mechanical lateral distal femoral angle (mLDFA), mechanical medial proximal tibial angle (mMPTA), and anatomical tibio-femoral angle (TFA) (for the overall alignment of lower limbs). Implant removal was done after 5° of overcorrection was achieved. The rate of correction (° per month) and complications related to each technique were recorded.ResultsThe most common diagnosis was idiopathic genu valgum. The overall rate of correction (TFA) was 1.2° for staples and 1.4° for eight plate (p = 0.70, not statistically significant). The correction in mLDFA was statistically better in the eight plate group, whereas an opposite trend was recorded in mMPTA. Implant-related complications were present in two cases of the staples group.ConclusionAlthough the overall correction rate was similar in both groups, implant-related complications were lower with figure of eight plate. In idiopathic genu valgum (the most common diagnosis), the correction was statistically better in the eight plate group. We recommend figure of eight plate over staples in managing these deformities.
Introduction: There is a lack of in vivo studies comparing the functional outcome and knee stability after anterior cruciate ligament reconstruction (ACLR) using fixed loop (EndoButton (EB) CL) and adjustable loop (TightRope (TR) RT) devices for femoral fixation of soft tissue grafts. Materials and methods: Functional outcomes were assessed in terms of the International Knee Documentation Committee (IKDC) and Lysholm scores, knee stability by anteroposterior laxity and side-to-side difference (SSD) using KT-1000 arthrometer. The evaluation was performed preoperatively and postoperatively at 6 months and 2 years. Results: Both groups were matched in terms of demographic, preoperative, intraoperative and post-operative covariates. EB (n ¼ 52) appeared to have better IKDC and Lysholm scores at 6 months post-operative when compared to TR (n ¼ 50). However, at a final follow-up of 2 years, the results were similar. The anterior tibial translation and SSD were statistically insignificant between the two groups at 6 months and 2 years. Conclusion: ACLR using EB or TR for femoral fixation gives substantially equivalent functional results and knee stability at mid-term follow-up.
Stable reconstruction and early initiation of physiotherapy are utilitarian to envision optimal outcome; the use of precontoured extra-articular distal humerus locking plates has yielded satisfactory results with minimal complications in our hands.
Oxford unicompartmental knee replacement (OUKR) has shown excellent long-term clinical outcomes as well as implant survival when used for correct indications with optimal surgical technique. Anteromedial osteoarthritis is highly prevalent in Indian patients, and OUKR is the ideal treatment option in such cases. Uncertainty prevails about the best method to determine femoral component size in OUKR. Preoperative templating has been shown to be inaccurate, while height- and gender-based guidelines based on European population might not apply to the Indian patients. Microplasty instrumentation introduced in 2012 introduced the sizing spoon, which has the dual function of femoral component sizing and determining the level of tibia cut. We aimed to check the accuracy of sizing spoon and also to determine whether the present guidelines are appropriate for use in the Indian patients. A total of 130 consecutive Oxford mobile bearing medial cemented UKR performed using the Microplasty instrumentation were included. The ideal femoral component size for each knee was recorded by looking for overhang and underhang in post-operative lateral knee radiograph. The accuracy of previous guidelines was determined by applying them to our study population. Previously published guidelines (which were based on Western population) proved to be accurate in only 37% of cases. Hence, based on the demographics of our study population, we formulated modified height- and gender-based guidelines, which would better suit the Indian population. Accuracy of modified guidelines was estimated to be 74%. The overall accuracy of sizing spoon (75%), when used as an intraoperative guide, was similar to that of modified guidelines. Existing guidelines for femoral component sizing do not work in Indian patients. Modified guidelines and use of intraoperative spoon should be used to choose the optimal implant size while performing OUKR in Indian patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.