The aim of this investigation was to determine the reliability of normalizing rapid force (RF) production to peak force assessed during an isometric knee flexor assessment, and to present a novel method of classifying athletes' potential training needs within the 90À90 isometric hamstring assessment. Procedures: Twenty elite female soccer players (age: 20.7 § 4.7 years; height: 168.2 § 5.5 cm; body mass: 62.8 § 7.0 kg), with no recent (>6 months) history of hamstring strain injury, volunteered to participate in the study. Following a standardized warm-up, each participant performed three maximal isometric hamstring contractions, with their heel resting on a force plate, elevated on a box, to ensure that their hips and knees were at 90°Data was analyzed to determine peak for (PF), RF was established as force expressed at 100 ms (F100) and force expressed at 200 ms (F200), with force at each time-point subsequently normalized to a percentage of PF. Findings: F100 and F200 normalized to PF demonstrated good absolute reliability (%CV = 6.12À7.62) and moderate relative reliability (ICC = 0.689À0.703). Concurrently observing PF and normalized F100 and F200 could provide clear training and monitoring goals. Conclusions: Normalizing measures of RF production, including F100 and F200, to PF can be performed reliability. Therefore, could be tracked overtime to identify changes as an effect of training or for fatigue monitoring purposes. However, further research is required to determine how knee flexor force-time characteristics change in relation to focused training and how these characteristics change in response to fatiguing activities.
Cloud computing faces more security threats, requiring better security measures. This paper examines the various classification and categorization schemes for cloud computing security issues, including the widely known CIA trinity (confidentiality, integrity, and availability), by considering critical aspects of the cloud, such as service models, deployment models, and involved parties. A comprehensive comparison of cloud security classifications constructs an exhaustive taxonomy. ISO27005, NIST SP 800-30, CRAMM, CORAS, OCTAVE Allegro, and COBIT 5 are rigorously compared based on their applicability, adaptability, and suitability within a cloud-based hosting methodology. The findings of this research recommend OCTAVE Allegro as the preferred cloud hosting paradigm. With many security models available in management studies, it is imperative to identify those suitable for the rapidly expanding and dynamically evolving cloud environment. This study underscores the significant methods for securing data on cloud-hosting platforms, thereby contributing to establishing a robust cloud security taxonomy and hosting methodology.
The aim of this investigation was to determine the reliability of normalizing rapid force (RF) production to peak force assessed during an isometric knee flexor assessment, and to present a novel method of classifying athletes' potential training needs within the 90À90 isometric hamstring assessment. Procedures: Twenty elite female soccer players (age: 20.7 § 4.7 years; height: 168.2 § 5.5 cm; body mass: 62.8 § 7.0 kg), with no recent (>6 months) history of hamstring strain injury, volunteered to participate in the study. Following a standardized warm-up, each participant performed three maximal isometric hamstring contractions, with their heel resting on a force plate, elevated on a box, to ensure that their hips and knees were at 90°Data was analyzed to determine peak for (PF), RF was established as force expressed at 100 ms (F100) and force expressed at 200 ms (F200), with force at each time-point subsequently normalized to a percentage of PF. Findings: F100 and F200 normalized to PF demonstrated good absolute reliability (%CV = 6.12À7.62) and moderate relative reliability (ICC = 0.689À0.703). Concurrently observing PF and normalized F100 and F200 could provide clear training and monitoring goals. Conclusions: Normalizing measures of RF production, including F100 and F200, to PF can be performed reliability. Therefore, could be tracked overtime to identify changes as an effect of training or for fatigue monitoring purposes. However, further research is required to determine how knee flexor force-time characteristics change in relation to focused training and how these characteristics change in response to fatiguing activities.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.