Main text
This key comparison is being performed to evaluate the degree of equivalence of measurement procedures to support the participants' claims of Calibration and Measurement Capabilities (CMCs) and to evaluate the capabilities of participants for the determination of the pH of carbonate buffer solutions.
This is the fourth APMP key comparison on pH measurement following APMP.QM-K9/P16 (phosphate), APMP.QM-K19/P25 (borate) and APMP.QM-K91/P29 (phthalate).
The results have the linkage to CCQM-K18.2016 (carbonate buffer) and were evaluated by comparing the results of the Physikalisch-Technische Bundesanstalt (PTB) and the National Metrology Institute of Japan (NMIJ) performing Harned cell method. The results of PTB and NMIJ were used for the definition of the Key Comparison Reference Value (KCRV). The ensuing pH value was calculated based on the Bates-Guggenheim convention to compare the results of primary and secondary methods.
In this comparison measurements of pH were performed only at the temperature of 25 °C.
The results demonstrated by most participants are in better agreement than those in CCQM-K18.2016.
To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.
The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Key comparison (KC) CCQM-K18.2016 was performed to evaluate the degree of equivalence between pH measurement results on an unknown carbonate buffer reported by participating National Metrology Institutes and Designated Institutes (NMI/DIs). The participants used the highest metrological method existing at their institution. The nominal buffer pH was 10.0 and was determined only at 25 °C. Good agreement of the results is demonstrated by most participants.
Main text
To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.
The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.