This report presents the results of a comparison of measurements on four electronic DC reference standards performed by national metrology institutes in the EUROMET region and BIPM. The results of the comparison, in terms of degrees of equivalence, show that there is a good agreement between the measurement results of the participants. The results also show that the time-dependent fluctuations in the output voltages of the travelling standards provide one of the main sources of uncertainty.Main text.
To reach the main text of this paper, click on
Final Report.
Note that this text is that which appears in Appendix B of the BIPM
key comparison database
kcdb.bipm.org/.The final report has been peer-reviewed and approved for publication
by the EUROMET, comparison identifier EUROMET.EM.BIPM-K11, according to the
provisions of the Mutual Recognition Arrangement (MRA).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.