EUROMET project no 429: Comparison of 10 V electronic voltage standards

Abstract: This report presents the results of a comparison of measurements on four electronic DC reference standards performed by national metrology institutes in the EUROMET region and BIPM. The results of the comparison, in terms of degrees of equivalence, show that there is a good agreement between the measurement results of the participants. The results also show that the time-dependent fluctuations in the output voltages of the travelling standards provide one of the main sources of uncertainty.Main text. To reach … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2003
2003
2017
2017

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 0 publications
0
3
0
Order By: Relevance
“…NMIs and ILCs providers have to provide suitable ILCs to correctly verify the capabilities of secondary laboratories. ILCs concerning the calibration of only fixed electrical standards [1][2][3][4][10][11][12] unfortunately don't cover the wide operating fields of modern secondary electrical calibration laboratories. An instrument covering wide fields and used by INRIM for several years in ILCs with these laboratories is the 8.5-digit high precision DMM.…”
Section: Choice Of Suitable Instruments For Ilcsmentioning
confidence: 99%
See 2 more Smart Citations
“…NMIs and ILCs providers have to provide suitable ILCs to correctly verify the capabilities of secondary laboratories. ILCs concerning the calibration of only fixed electrical standards [1][2][3][4][10][11][12] unfortunately don't cover the wide operating fields of modern secondary electrical calibration laboratories. An instrument covering wide fields and used by INRIM for several years in ILCs with these laboratories is the 8.5-digit high precision DMM.…”
Section: Choice Of Suitable Instruments For Ilcsmentioning
confidence: 99%
“…The traceability chain of the INRIM-Lab from national standards is shown in The measurement uncertainties of the two laboratories were respectively evaluated in calibration procedures respectively approved by INRIM as signatory of the CIPM MRA 1 and by the Italian calibration Accreditation body ACCREDIA. The uncertainties reported in the INRIM-Lab procedures were evaluated according to the criteria defined in [5].…”
Section: Traceability To National Standards Of the Inrim-lab And Of T...mentioning
confidence: 99%
See 1 more Smart Citation