The role of wear debris in provoking joint replacement failure through bone resorption is now supported by much research. This study presents the analysis of 104 tissue samples using laser diffraction wear particle analysis in conjunction with standard histologic methods. The number and volume distributions were correlated to a range of joint and patient parameters. The median particle diameter by number was 0.69 microm. No particles smaller than 0.113 microm were resolved. No variation in terms of particle distribution was found among joint types. The ability of particles to migrate away from their point of origin was found to be inversely proportional to their size. The numbers of particles per gram of tissue found in various regions around the prosthesis varied little. Further, the numbers of particles in tissue samples shown to have a chronic foreign-body reaction was> 1 x 10(9) particles/gram.
New generation metal-on-metal prostheses have been introduced to try and overcome the problem of osteolysis often attributed to the wear particles of the polyethylene component of conventional metal-on-ultra-high molecular weight polyethylene (UHMWPE) joints. The wear rates of four metal-on-metal joints (two different clearances) were assessed along with that of a conventional metal-on-UHMWPE joint. Friction measurements of the metal-on-metal joints were taken before and after the wear test and compared. Two distinct wear phases were discernible for all the metal-on-metal joints: an initial wear phase up to 0.5 x 10(6) cycles and then a lower steady state wear phase. The steady state wear rate of the 22 microm radial clearance metal-on-metal joint was lower than that for the 40 microm radial clearance joint, although this difference was not found to be significant (p > 0.15). The wear rates for all the joints tested were consistent with other simulator studies. The friction factors produced by each joint were found to decrease significantly after wear testing (p < 0.05).
The Swedish hip register found an increased risk of early revision of vacuum-mixed cemented total hip replacements. The influence of cement mixing technique on the dynamic volume change in polymerising PMMA is not well understood and may be relevant to this observation. Applying Archimedes' principle, we have investigated the dynamic volume changes in polymerising cement and determined the influence of mixing technique. All specimens showed an overall volume reduction: hand-mixed 3.4% and vacuum-mixed 6.0%. Regression analysis of sectional porosity and volume reduction showed a highly significant relationship. Hand-mixed porous cement showed a transient volume increase before solidification. However, vacuum-mixed cement showed a progressive volume reduction throughout polymerisation. Transient expansion of porous cement occurs at the critical time of micro-interlock formation, possibly improving fixation. Conversely, progressive volume reduction of vacuum-mixed cement throughout the formation of interlock may damage fixation. Stable fixation of vacuum-mixed cement may depend on additional techniques to offset the altered volumetric behaviour of vacuum-mixed cement.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.