Disturbances in nitric oxide (NO) metabolism resulting in endothelial dysfunction play a central role in the pathogenesis of atherosclerosis in hypercholesterolemia and in individuals with type 2 diabetes. It is unclear whether lipid lowering therapy with HMG-CoA-reductase inhibitors might improve endothelial function in subjects with type 2 diabetes as it is demonstrated in non-diabetic subjects with hypercholesterolemia. We examined the influence of 0.2 mg and 0.8 mg cerivastatin on endothelial function in a multicenter, randomised, double-blind, and three-arm placebo-controlled clinical trial. Endothelial function was assessed by nitric oxide-dependent flow mediated vasodilatation (FMD) of the brachial artery. A total of 103 patients with type 2 diabetes were enrolled in the study. Bayer Company undertook a voluntary action to withdraw cerivastatin from market, therefore the study was terminated earlier. At this point 77 patients were randomised, of which 58 completed the study (mean age 60 +/- 8 years, HbA1c 7.4 +/- 0.9 %). At baseline mean FMD was disturbed in all three therapy arms (5.18 +/- 2.31 % in the placebo group, 3.88 +/- 1.68 in the 0.2-mg cerivastation group, and 4.86 +/- 2.25 in the 0.8-mg cerivastatin group). Despite a significant reduction in cholesterol and LDL-cholesterol-levels after 12 weeks of treatment (decrease in LDL-cholesterol - 26.8 +/- 13.9 % in the 0.2-mg group and - 40.3 +/- 16.0 % in the 0.8-mg group, p = 0.0001, ANCOVA) there was no difference in flow mediated vasodilatation (p = 0.52 and p = 0.56 vs. placebo, respectively, ANCOVA). HbA1c, CRP, and HDL-cholesterol did not change during the study. Furthermore no difference in safety profile between cerivastatin and placebo was found. Despite a significant improvement in lipid profile under statin therapy, no improvement of endothelial dysfunction in terms of nitric oxide bioavailability could be detected.
30 training measurements of FAD under supervision should be regarded as minimum requirement for valid determination of endothelial function. The reachable result for the intra-observer variability is thereby within the range of computed analysis systems.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.