Following the deployment of a coronary stent and disruption of an atheromatous plaque, the deformation of the arterial wall and the presence of the stent struts create a new fluid dynamic field, which can cause an abnormal biological response. In this study 3D computational models were used to analyze the fluid dynamic disturbances induced by the placement of a stent inside a coronary artery. Stents models were first expanded against a simplified arterial plaque, with a solid mechanics analysis, and then subjected to a fluid flow simulation under pulsatile physiological conditions. Spatial and temporal distribution of arterial wall shear stress (WSS) was investigated after the expansion of stents of different designs and different strut thicknesses. Common oscillatory WSS behavior was detected in all stent models. Comparing stent and vessel wall surfaces, maximum WSS values (in the order of 1Pa) were located on the stent surface area. WSS spatial distribution on the vascular wall surface showed decreasing values from the center of the vessel wall portion delimited by the stent struts to the wall regions close to the struts. The hemodynamic effects induced by two different thickness values for the same stent design were investigated, too, and a reduced extension of low WSS region (<0.5Pa) was observed for the model with a thicker strut.
The close correlation between predicted and observed data supports the use of mathematic modeling in the design and assessment of surgical procedures. The potentially damaging effects of a systemic ventriculotomy in the right ventricle-pulmonary artery shunt modification of the Norwood operation have not been analyzed.
The construction of efficient designs with minimal energy losses is especially important for cavopulmonary connections. The science of computational fluid dynamics has been increasingly used to study the hemodynamic performance of surgical operations. Three-dimensional computer models can be accurately constructed of typical cavopulmonary connections used in clinical practice based on anatomic data derived from magnetic resonance scans, angiocardiograms, and echocardiograms. Using these methods, the hydraulic performance of the hemi-Fontan, bidirectional Glenn, and a variety of types of completion Fontan operations can be evaluated and compared. This methodology has resulted in improved understanding and design of these surgical operations.
This work addresses the problem of prescribing proper boundary conditions at the artificial boundaries that separate the vascular district from the remaining part of the circulatory system. A multiscale (MS) approach is used where the Navier-Stokes equations for the district of interest are coupled to a non-linear system of ordinary differential equations which describe the circulatory system. This technique is applied to three 3D models of a carotid bifurcation with increasing stenosis resembling three phases of a plaque growth. The results of the MS simulations are compared to those obtained by two stand-alone models. The MS shows a great flexibility in numerically predicting the haemodynamic changes due to the presence of a stenosis. Nonetheless, the results are not significantly different from a stand-alone approach where flows derived by the MS without stenosis are imposed. This is a consequence of the dominant role played by the outside districts with respect to the stenosis resistance.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.