There were 35 oesophageal intubations in the first 2000 incidents reported to the Australian Incident Monitoring Study (AIMS). These reports confirm existing impressions that misplacement of the endotracheal tube can occur in trained as well as untrained hands, and that auscultation is an unreliable test. On the other hand, the value of capnography is emphasised, with no false positives in the 16 cases in which the instrument was used. There was one false negative. Over the 4 years of the AIMS study, reports have declined in frequency. It is possible that the early detection of oesophageal intubation by capnography has altered its status to the extent that anaesthetists no longer regard it as a “critical” incident. It is highly recommended that the presence of the expected concentration of carbon dioxide in expired air be confirmed by capnography immediately after any endotracheal intubation.
Although 70-80% of problems have some component of human error, its overall contribution to many problems may be small; studies of complex systems have revealed that up to 85 % are primarily due to deficiencies in the layout and processes of the system. The anaesthetist has to operate in a complex system; many problems originate from deficiencies in this system. Information of relevance to system failure was extracted from the first 2000 incidents reported to the Australian Incident Monitoring Study (AIMS). A system-based deficiency directly contributed to one-quarter of problems (four-fifths if human factors are included), some aspect of the system minimized the adverse outcome in over half of all cases (four-fifths if human factors are included), and in two-thirds (three-quarters if human factors are included) a system-based strategy would have been helpful; the system was implicated in 90% of all incidents (97% if human factors are included). Regardless of whether or not all human error should be regarded as part of the "system'; attempts to modify its incidence and nature have to emanate from the system. AIMS reporting pathways and the organizations involved in developing and implementing strategies to improve the system operate at four levels. Level I involves the use of AIMS reports by hospitals and group practices for audit at a local level. Level Il involves AIMS participants sending forms to the AIMS central office; collated information is then sent back to contributors by newsletter. Level III involves interaction between AIMS and the major professional bodies and level IV interaction between AIMS, these bodies and a variety of national and international agencies. Over 100 topics were identified from the AIMS data for consideration at one or more of these levels. AIMS has the potential not only to play a vital practical role in the continued enhancement of the quality of anaesthetic practice, but also to provide a valuable resource for research at the increasingly important interface between human behaviour and complex systems.
The prerequisites for a change in practice in individual pharmacists, as framed by the Holland-Nimmo practice change model, are discussed. The Holland-Nimmo practice change model comprises three components, all of which must be addressed by a pharmacy's leadership if a change in practice is to be achieved. The first component is the practice environ
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.