A simple procedure for preparing inexpensive paper-based three-electrode electrochemical cells is described here. They consist of small circular pads of hydrophilic paper defined by hydrophobic barriers printed on paper with wax-based ink. The back face of these pads is insulated by thermally laminating a polyethylene layer and working, reference and counter electrodes are drawn on paper by using commercial pencil leads. At last, a controlled volume of sample containing a supporting electrolyte was laid to soak in paper channels. Their performance was evaluated by assaying these devices as both simple cells suitable for recording voltammograms on static samples and low-cost detectors for flowing systems. Voltammetric tests, conducted by using potassium hexacyanoferrate(II) as model prototype, were also exploited for identifying the brand and softness of graphite sticks enabling paper to be marked with lines displaying the best conductivity. By taking advantage of the satisfactory information thus gained, pencil drawn electrodes were tested as amperometric detectors for the separation of ascorbic acid and sunset yellow, which were chosen as prototype electroactive analytes because they are frequently present concomitantly in several food matrices, such as soft drinks and fruit juices. This separation was performed by planar thin layer chromatography conducted on microfluidic paper-based devices prepared by patterning on filter paper two longitudinal hydrophobic barriers, once again printed with wax-based ink. Factors affecting both separation and electrochemical detection were examined and optimised, with best performance achieved by using a 20 mM acetate running buffer (pH 4.5) and by applying a detection potential of 0.9 V. Under these optimum conditions, the target analytes could be separated and detected within 6 min. The recorded peaks were well separated and characterized by good repeatability and fairly good sensitivity, thus proving that this approach is indeed suitable for rapidly assembling inexpensive and reliable electrochemical detectors for flow analysis systems.
A sensitive and fast-responding membrane-free amperometric gas sensor is described, consisting of a small filter paper foil soaked with a room temperature ionic liquid (RTIL), upon which three electrodes are screen printed with carbon ink, using a suitable mask. It takes advantage of the high electrical conductivity and negligible vapour pressure of RTILs as well as their easy immobilization into a porous and inexpensive supporting material such as paper. Moreover, thanks to a careful control of the preparation procedure, a very close contact between the RTIL and electrode material can be achieved so as to allow gaseous analytes to undergo charge transfer just as soon as they reach the threephase sites where the electrode material, paper supported RTIL and gas phase meet. Thus, the adverse effect on recorded currents of slow steps such as analyte diffusion and dissolution in a solvent is avoided. To evaluate the performance of this device, it was used as a wall-jet amperometric detector for flow injection analysis of 1-butanethiol vapours, adopted as the model gaseous analyte, present in headspace samples in equilibrium with aqueous solutions at controlled concentrations. With this purpose, the RTIL soaked paper electrochemical detector (RTIL-PED) was assembled by using 1butyl-3-methylimidazolium bis(trifluoromethanesulfonyl)imide as the wicking RTIL and printing the working electrode with carbon ink doped with cobalt(II) phthalocyanine, to profit from its ability to electrocatalyze thiol oxidation. The results obtained were quite satisfactory (detection limit: 0.5 mM; dynamic range: 2-200 mM, both referring to solution concentrations; correlation coefficient: 0.998; repeatability: AE7% RSD; long-term stability: 9%), thus suggesting the possible use of this device for manifold applications.
A highly sensitive and fast-responding electroanalytical sensor for the determination of hydrogen sulfide in Project "Sistema Lagunare Veneziano" is gratefully acknowledged.
Electroanalytical sensors, suitable for the analysis and monitoring of electroactive analytes present in gaseous phase or low-conductive liquid media, and based on electrodes in close contact with perfluorinated ion-exchange polymers are reviewed. The basic operative mechanism of these sensors, in which ion-exchange polymers act as solid polymer electrolytes (SPE's), is thoroughly discussed, while stressing the fundamental reasons why their behavior differs from that of conventional membrane electrodes. The procedures for preparing composite working electrodes by coating one side of ion-exchange membranes with stable porous films of conductive materials are described, along with the most common strategies followed to assemble this type of sensors. Useful examples of measurements in electrolyte-free media of inorganic and organic electroactive species of interest mainly for environmental analysis are given. Future prospects for the development of these sensors are also discussed.
A simple method is described to discriminate between analytes comigrating under on‐plate separation conditions, whose electrochemical behavior displays different reversible characters. It is based on the use of dual electrode detectors pencil‐drawn at the end of paper‐based fluidic channels defined by hydrophobic barriers. Simultaneous detection of comigrating species is achieved by applying to the upstream pencil‐drawn working electrode a potential for the oxidation (or reduction) of both analytes, while to the downstream pencil‐drawn working electrode a potential is imposed for the reverse process involving the product of the sole analyte undergoing a reversible enough electrochemical process. The performance of these inexpensive devices was preliminarily optimized by adopting hexacyanoferrate(II) as prototype species undergoing a reversible anodic process at carbon electrodes. They were then used as dual electrode detectors for thin‐layer chromatographic runs conducted on paper‐based microfluidic devices. Two types of synthetic solutions, one containing different contents of dopamine (DA) and ascorbic acid (AA) and the other of paracetamol (PA) and AA, were chosen as model samples. This choice was prompted us by the fact that in both cases these analytes comigrated under the adopted experimental conditions and required similar enough oxidation potentials. Nevertheless, DA and PA underwent reversible enough anodic processes while an irreversible electrochemical reaction is involved in the AA oxidation. Satisfactory results were found for both couples of target analytes, whose simultaneous detection was achieved within 230 s and was characterized by good enough repeatability and sensitivity. In particular, this approach appears to be well suited for the rapid and inexpensive assembling of electrochemical detectors for flow analysis systems.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.